Javascript must be enabled to continue!
A Novel Gas-Assist Atomizer for Power Stations
View through CrossRef
A novel high flow rate gas-assist atomizer for liquid atomization was developed. The method of liquid supply in the zone of maximal air velocity is used. It is shown that it is possible to achieve fine atomization as the relative velocity between gas and liquid is very high. However actual sprays have droplets with larger size due to the rapid decrease of the difference between air and liquid velocities. So droplets disintegrate mainly due to the turbulent velocity fluctuations of the air flow. The experimental study included two stages: laboratory tests and field tests inside a full size boiler of a 220 MW power station. At the first stage, several atomizer modifications were tested using water and compressed air. Droplet size was measured by a special Laser Light Scattering method. Liquid flow rate was equal to 3500 kg/hr. The liquid atomization quality at each cross-section of the spray was estimated by measuring the liquid-droplets sizes at several stations across the spray. The tests were carried out for two distances, 30 and 40 cm, downstream of the nozzle. The tests show that for the proposed atomizer droplets SMD was reduced from 135 to 67 microns. Droplets SMD maintains constant value when liquid flow rate is reduced by 50%. The spray angle was kept as in a standard atomizer and equal to 110 degrees under all operating conditions. It was found that to obtain this angle, the pressure downstream of the nozzle core should be atmospheric. The atomizer with the best performances was selected for the field tests. It was assumed that the atomizer which shows the best results for air-water mixture would be superior also for steam-fuel mixture. Field tests of the atomizer within the burner of an actual power station in Israel (boiler by Babcock Borsig Company), demonstrated a significant reduction in NOx content, from 540 to 270 ppmv as well as better service conditions.
Title: A Novel Gas-Assist Atomizer for Power Stations
Description:
A novel high flow rate gas-assist atomizer for liquid atomization was developed.
The method of liquid supply in the zone of maximal air velocity is used.
It is shown that it is possible to achieve fine atomization as the relative velocity between gas and liquid is very high.
However actual sprays have droplets with larger size due to the rapid decrease of the difference between air and liquid velocities.
So droplets disintegrate mainly due to the turbulent velocity fluctuations of the air flow.
The experimental study included two stages: laboratory tests and field tests inside a full size boiler of a 220 MW power station.
At the first stage, several atomizer modifications were tested using water and compressed air.
Droplet size was measured by a special Laser Light Scattering method.
Liquid flow rate was equal to 3500 kg/hr.
The liquid atomization quality at each cross-section of the spray was estimated by measuring the liquid-droplets sizes at several stations across the spray.
The tests were carried out for two distances, 30 and 40 cm, downstream of the nozzle.
The tests show that for the proposed atomizer droplets SMD was reduced from 135 to 67 microns.
Droplets SMD maintains constant value when liquid flow rate is reduced by 50%.
The spray angle was kept as in a standard atomizer and equal to 110 degrees under all operating conditions.
It was found that to obtain this angle, the pressure downstream of the nozzle core should be atmospheric.
The atomizer with the best performances was selected for the field tests.
It was assumed that the atomizer which shows the best results for air-water mixture would be superior also for steam-fuel mixture.
Field tests of the atomizer within the burner of an actual power station in Israel (boiler by Babcock Borsig Company), demonstrated a significant reduction in NOx content, from 540 to 270 ppmv as well as better service conditions.
Related Results
Characteristics of Spray Angle and Discharge Coefficient of Pressure-Swirl Atomizer
Characteristics of Spray Angle and Discharge Coefficient of Pressure-Swirl Atomizer
A widely distributed spray is an important feature for an atomizer which is required in various applications such as gas cooling, gas turbine combustion, and fluidized bed granulat...
Experimental Investigation on Atomization Characteristics of Ultrasonic Atomizer
Experimental Investigation on Atomization Characteristics of Ultrasonic Atomizer
<div class="htmlview paragraph">An exeperimental study on the atomization characteristics of an ultrasonic Atomizer utilizing pulse laser holographic system is presented in t...
Comparisons of Pore Structure for Unconventional Tight Gas, Coalbed Methane and Shale Gas Reservoirs
Comparisons of Pore Structure for Unconventional Tight Gas, Coalbed Methane and Shale Gas Reservoirs
Extended abstract
Tight sands gas, coalbed methane and shale gas are three kinds of typical unconventional natural gas. With the decrease of conventional oil and gas...
Critical Gas Saturation During Depressurisation and its Importance in the Brent Field
Critical Gas Saturation During Depressurisation and its Importance in the Brent Field
Critical Gas Saturation During Depressurisation and its Importance in the Brent Field.
Abstract
After some 20 years of pressure ...
Unconventional Reservoirs: Basic Petrophysical Concepts for Shale Gas
Unconventional Reservoirs: Basic Petrophysical Concepts for Shale Gas
Abstract
Unconventional reservoirs have burst with considerable force in oil and gas production worldwide. Shale Gas is one of them, with intense activity taking pla...
A New IPR Curve Of Gas-Water Well In Gas Reservoirs Undergoing Simultaneous Water Production
A New IPR Curve Of Gas-Water Well In Gas Reservoirs Undergoing Simultaneous Water Production
Abstract
Based on principle of mass conservation, this paper sets up a new mathematical model of gas-water two-phase underground percolation, and the model includ...
Understanding Unconventional Gas Reservoir Damages
Understanding Unconventional Gas Reservoir Damages
Abstract
It is estimated that there are large reserves of unconventional gas located throughout the world, including coalbed methane, shale gas and tight gas sand...
Experimental Investigation of Choked Flow Conditions for Bubbly Flow
Experimental Investigation of Choked Flow Conditions for Bubbly Flow
Abstract
In an effervescent atomizer, a bubbly two-phase mixture flows through a convergent section before exhausting from an exit orifice. It is commonly believed t...

