Javascript must be enabled to continue!
Superimposed High Frequency Jet Ventilation Minimises Diaphragm, Bronchus, and Mediastinum Motion during One-Lung Flooding
View through CrossRef
Background: One-Lung Flooding (OLF) represents an ideal acoustic pathway for focused ultrasound ablation of lung tumours. Despite stabilization of the adjacent hemidiaphragm by OLF, standard Pressure-Controlled Ventilation (PCV) of the contralateral lung causes an unacceptable movement of the flooded lung. We examined whether Superimposed High Frequency Jet Ventilation (SHFJV) reduces lung motion compared to PCV during OLF. Methods: The study included 15 pigs: 10 underwent OLF; 5 controls underwent two-lung ventilation without OLF. Using ultrasound, diaphragm displacement on the flooded lung side was measured during PCV and SHFJV in the left lateral (LLP), Supine (SP), and Right Lateral Positions (RLP). Bronchus and mediastinum displacements were measured in the right lateral position. Results: Diaphragm displacement on the flooded lung side was significantly reduced during SHFJV, compared with PCV, in all animal positions (LLP: 7mm [4.75-8.0] vs. 17mm [14.75-19.0], P=0.0039; SP: 4mm [3.75-4.25] vs. 17mm [16.0–18.5], P=0.0039; RLP: 8mm [5.75-9.0] vs. 20mm [14.0-23.25], P=0.0078). Displacement of both the bronchus and mediastinum were significantly reduced during SHFJV, compared with PCV, in RLP (bronchus: 2.0mm [1.75-2.25] vs. 3.0mm [2.75-3.0], P=0.027; mediastinum: 4.5mm [4.0-5.0] vs. 10mm [7.0-10.0], P=0.0078. Conclusion: Thus, SHFJV minimises diaphragm, bronchus, and mediastinum motion during OLF, which is a prerequisite for effective lung tumour ablation.
Title: Superimposed High Frequency Jet Ventilation Minimises Diaphragm, Bronchus, and Mediastinum Motion during One-Lung Flooding
Description:
Background: One-Lung Flooding (OLF) represents an ideal acoustic pathway for focused ultrasound ablation of lung tumours.
Despite stabilization of the adjacent hemidiaphragm by OLF, standard Pressure-Controlled Ventilation (PCV) of the contralateral lung causes an unacceptable movement of the flooded lung.
We examined whether Superimposed High Frequency Jet Ventilation (SHFJV) reduces lung motion compared to PCV during OLF.
Methods: The study included 15 pigs: 10 underwent OLF; 5 controls underwent two-lung ventilation without OLF.
Using ultrasound, diaphragm displacement on the flooded lung side was measured during PCV and SHFJV in the left lateral (LLP), Supine (SP), and Right Lateral Positions (RLP).
Bronchus and mediastinum displacements were measured in the right lateral position.
Results: Diaphragm displacement on the flooded lung side was significantly reduced during SHFJV, compared with PCV, in all animal positions (LLP: 7mm [4.
75-8.
0] vs.
17mm [14.
75-19.
0], P=0.
0039; SP: 4mm [3.
75-4.
25] vs.
17mm [16.
0–18.
5], P=0.
0039; RLP: 8mm [5.
75-9.
0] vs.
20mm [14.
0-23.
25], P=0.
0078).
Displacement of both the bronchus and mediastinum were significantly reduced during SHFJV, compared with PCV, in RLP (bronchus: 2.
0mm [1.
75-2.
25] vs.
3.
0mm [2.
75-3.
0], P=0.
027; mediastinum: 4.
5mm [4.
0-5.
0] vs.
10mm [7.
0-10.
0], P=0.
0078.
Conclusion: Thus, SHFJV minimises diaphragm, bronchus, and mediastinum motion during OLF, which is a prerequisite for effective lung tumour ablation.
Related Results
Mechanism Study on Foam Flooding for Daqing Reservoirs After Polymer Flooding
Mechanism Study on Foam Flooding for Daqing Reservoirs After Polymer Flooding
Abstract
Polymer flooding has been carried out widely in Daqing oilfield. The average oil recovery was 53% and the water cut was more than 90% after polymer flooding...
SHAPE CHARACTERIZATION OF MEDIASTINUM IN TUBERCULOSIS CHEST RADIOGRAPHS USING LEVEL SET SEGMENTATION
SHAPE CHARACTERIZATION OF MEDIASTINUM IN TUBERCULOSIS CHEST RADIOGRAPHS USING LEVEL SET SEGMENTATION
Mediastinum is considered as one of the substantial anatomical regions for the gross diagnosis of several chest related pathologies. The geometric variations of the mediastinum in ...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Cavitation in Submerged Water Jet at High Jet Pressure
Cavitation in Submerged Water Jet at High Jet Pressure
Recent industrial applications have unfolded a promising prospect for submerged water jet. Apart from widely acknowledged water jet properties, submerged water jet is characterized...
Ultrasonographic evaluation of diaphragm function in patients with chronic obstructive pulmonary disease: A systematic review and meta-analysis
Ultrasonographic evaluation of diaphragm function in patients with chronic obstructive pulmonary disease: A systematic review and meta-analysis
Background:
Some studies have reported using ultrasonic evaluations to assess diaphragm function in patients with chronic obstructive pulmonary disease (COPD). However,...
Studies On Foam Flooding EOR Technique For Daqing Reservoirs After Polymer Flooding
Studies On Foam Flooding EOR Technique For Daqing Reservoirs After Polymer Flooding
Abstract
Most of the high permeability reservoirs in Daqing oil field have been conducted by water flooding and polymer flooding.
The average oil reco...
Study on the image recognition of ammonia ignition process induced by methanol micro-jet
Study on the image recognition of ammonia ignition process induced by methanol micro-jet
<div class="section abstract"><div class="htmlview paragraph">Ammonia is regarded as a possible carbon-free energy source for engines, drawing more and more attention. ...
3D Printed Flexible Plastic Diaphragm for Optical Pressure Sensor Application
3D Printed Flexible Plastic Diaphragm for Optical Pressure Sensor Application
Introduction
Due to ongoing growth in automotive market, and also in order to respond the rising customers’ demands on driving the safe, comfort and ...