Javascript must be enabled to continue!
Research on Earthquake Acceleration Alarm of Nuclear Power Plant
View through CrossRef
Abstract
Almost all nuclear power plants in the world are equipped with seismic instrument system, especially the third generation nuclear power plants in China. When the ground motion measured by four time history accelerometers of containment foundation exceeds the preset threshold, the automatic shutdown trigger signal will be generated. However, from the seismic acceleration characteristics, isolated and prominent single high frequency will be generated the acceleration peak, which has no decisive effect on the seismic response, may cause false alarm, which has a certain impact on the smooth operation of nuclear power plant. According to the principle of three elements of ground motion, this paper puts forward a method that first selects the filtering frequency band which accords with the structural characteristics of nuclear power plants, then synthesizes the three axial acceleration time history, and finally selects the appropriate acceleration peak value for threshold alarm. The results show that the seismic acceleration results obtained by this method can well represent the actual magnitude of acceleration, and can solve the problem of false alarm due to the randomness of single seismic wave, and can be used for automatic reactor shutdown trigger signal of seismic acceleration.
Title: Research on Earthquake Acceleration Alarm of Nuclear Power Plant
Description:
Abstract
Almost all nuclear power plants in the world are equipped with seismic instrument system, especially the third generation nuclear power plants in China.
When the ground motion measured by four time history accelerometers of containment foundation exceeds the preset threshold, the automatic shutdown trigger signal will be generated.
However, from the seismic acceleration characteristics, isolated and prominent single high frequency will be generated the acceleration peak, which has no decisive effect on the seismic response, may cause false alarm, which has a certain impact on the smooth operation of nuclear power plant.
According to the principle of three elements of ground motion, this paper puts forward a method that first selects the filtering frequency band which accords with the structural characteristics of nuclear power plants, then synthesizes the three axial acceleration time history, and finally selects the appropriate acceleration peak value for threshold alarm.
The results show that the seismic acceleration results obtained by this method can well represent the actual magnitude of acceleration, and can solve the problem of false alarm due to the randomness of single seismic wave, and can be used for automatic reactor shutdown trigger signal of seismic acceleration.
Related Results
Animal Alarm Calls
Animal Alarm Calls
Alarm calls are broadly defined as calls occurring in a predator context. Alarm calls have been the subject of intense scrutiny in animal communication research, as they are releva...
Optimizing Multimodal Alarm Design for Attention Allocation in Discrete Monitoring Tasks
Optimizing Multimodal Alarm Design for Attention Allocation in Discrete Monitoring Tasks
Discrete monitoring tasks are common in scenarios such as flight missions, air traffic control, nuclear power plant monitoring, and clinical healthcare. In these tasks, operators p...
Alarm fatigue and perceived stress among critical care nurses in the intensive care units: Palestinian perspectives
Alarm fatigue and perceived stress among critical care nurses in the intensive care units: Palestinian perspectives
AbstractObjectiveThe frequency of alarms generated by monitors and other electro-medical devices is undeniably valuable but can simultaneously escalate the workload for healthcare ...
Evaluating the Alarm Fatigue and its Associated Factors among Clinicians in Critical Care Units
Evaluating the Alarm Fatigue and its Associated Factors among Clinicians in Critical Care Units
The Alarm Fatigue (AF) occurs when clinicians are exposed to a large number of false alarms which can cause alarm desensitization. AF is a well-recognized patient safety concern in...
Detecting False Alarms by Analyzing Alarm-Context Information: Algorithm Development and Validation (Preprint)
Detecting False Alarms by Analyzing Alarm-Context Information: Algorithm Development and Validation (Preprint)
BACKGROUND
Although alarm safety is a critical issue that needs to be addressed to improve patient care, hospitals have not given serious consideration abou...
Alarm rationalization in engineering projects: analyzing cost-saving measures and efficiency gains
Alarm rationalization in engineering projects: analyzing cost-saving measures and efficiency gains
Alarm rationalization is a critical process in engineering projects, focusing on optimizing alarm management systems to enhance operational efficiency, reduce costs, and improve sa...
Radiation Evaluation System for Radiation Releasing Environment of Nuclear Power Plant Based on Domain-Driven Design
Radiation Evaluation System for Radiation Releasing Environment of Nuclear Power Plant Based on Domain-Driven Design
In order to meet the sustainable development demand for energy, developing nuclear power actively has become an important means for the country to improve energy supply pattern and...
Why Do Birds False Alarm Flight?
Why Do Birds False Alarm Flight?
False alarm flighting in avian flocks is common, and has been explained as a maladaptive information cascade. If false alarm flighting is maladaptive per se, then its frequency can...

