Javascript must be enabled to continue!
Estimation of Parameters and Optimality of Second-Order Spherical Designs Using Quadratic Function Relative to Non-Spherical Face centered CCD
View through CrossRef
The study presented the estimation of parameters and optimality of second-order spherical designs using quadratic model in comparison to the non-spherical face centered CCD for varying axial distances. The designs considered were equiradial design of axial distances of 1.0 and 1.414, inscribed CCD of axial distance of 1.0 and circumscribed CCD of axial distance of 1.414, the study employed sum of square error, variance estimation, D-, A-, and T-optimality criteria as well as Grand mean of these designs for quadratic model and 1 to 10 center runs were considered. The study observed that the sum of square error of the non-spherical face centred CCD is zero (0) for radial point of n=5 with 1 centre point and this result is seen to be a misleading result, because, no process is 100%. While the sum of square error of the spherical designs with axial distance of 1.0 gave minimal sum of square errors and the spherical designs with axial distance of 1.414 gave very large sum of square error. The Grand mean of the spherical and the non-spherical designs were equal or approximately equal for radial point of n=5 for centre points 1-10 inclusive. But as the radial distance increases above 5, the Grand mean of the non-spherical CCD differs significantly from those of the spherical designs. The study suggests that the non-spherical second order design is inferior to their spherical second order design counterparts. The spherical designs with axial distance of 1.414 (equiradial and circumscribed CCD) have better D-optimality, A-optimality and T-optimality than the non-spherical face centred CCD, while, the spherical designs with axial distance of 1.0 (equiradial and inscribed) has inferior D-optimality, A-optimality and T-optimality compared to the non-spherical face centred CCD with axial distance of 1.0.
Sciencedomain International
Title: Estimation of Parameters and Optimality of Second-Order Spherical Designs Using Quadratic Function Relative to Non-Spherical Face centered CCD
Description:
The study presented the estimation of parameters and optimality of second-order spherical designs using quadratic model in comparison to the non-spherical face centered CCD for varying axial distances.
The designs considered were equiradial design of axial distances of 1.
0 and 1.
414, inscribed CCD of axial distance of 1.
0 and circumscribed CCD of axial distance of 1.
414, the study employed sum of square error, variance estimation, D-, A-, and T-optimality criteria as well as Grand mean of these designs for quadratic model and 1 to 10 center runs were considered.
The study observed that the sum of square error of the non-spherical face centred CCD is zero (0) for radial point of n=5 with 1 centre point and this result is seen to be a misleading result, because, no process is 100%.
While the sum of square error of the spherical designs with axial distance of 1.
0 gave minimal sum of square errors and the spherical designs with axial distance of 1.
414 gave very large sum of square error.
The Grand mean of the spherical and the non-spherical designs were equal or approximately equal for radial point of n=5 for centre points 1-10 inclusive.
But as the radial distance increases above 5, the Grand mean of the non-spherical CCD differs significantly from those of the spherical designs.
The study suggests that the non-spherical second order design is inferior to their spherical second order design counterparts.
The spherical designs with axial distance of 1.
414 (equiradial and circumscribed CCD) have better D-optimality, A-optimality and T-optimality than the non-spherical face centred CCD, while, the spherical designs with axial distance of 1.
0 (equiradial and inscribed) has inferior D-optimality, A-optimality and T-optimality compared to the non-spherical face centred CCD with axial distance of 1.
Related Results
Increased life expectancy of heart failure patients in a rural center by a multidisciplinary program
Increased life expectancy of heart failure patients in a rural center by a multidisciplinary program
Abstract
Funding Acknowledgements
Type of funding sources: None.
INTRODUCTION Patients with heart failure (HF)...
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Abstract
Introduction
Among the most frequently used anticoagulants in hematological testing are tetra-acetic acid (EDTA), sodium citrate, and sodium heparin. However, there is a n...
The Effects of Interactive Digital-Based Materials on Students’ Performance in Mathematics
The Effects of Interactive Digital-Based Materials on Students’ Performance in Mathematics
This study determined the effects of interactive digital-based materials on the performance in Mathematics of Grade 9 students in Vinisitahan National High School in Bacacay, Albay...
Stochastic continuous-time cash flows: A coupled linear-quadratic model
Stochastic continuous-time cash flows: A coupled linear-quadratic model
<p>The focal point of this dissertation is stochastic continuous-time cash flow models. These models, as underpinned by the results of this study, prove to be useful to descr...
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED]Keanu Reeves CBD Gummies ==❱❱ Huge Discounts:[HURRY UP ] Absolute Keanu Reeves CBD Gummies (Available)Order Online Only!! ❰❰= https://www.facebook.com/Keanu-Reeves-CBD-G...
Intelligent calibration of dual liner CCD intersection testing system based on Backpropagation neural network
Intelligent calibration of dual liner CCD intersection testing system based on Backpropagation neural network
Abstract
In order to improve the measurement accuracy and calibration efficiency of the dual liner Charge Couple Device (CCD) intersection measurement system, a cali...
Amyloid-mediated remineralization for tooth hypoplasia of cleidocranial dysplasia
Amyloid-mediated remineralization for tooth hypoplasia of cleidocranial dysplasia
IntroductionCleidocranial dysplasia (CCD) is an autosomal-dominant, heritable skeletal and dental disease, involving hypoplastic clavicles, defective ossification of the anterior f...
Care for Child Development: an intervention in support of responsive caregiving and early child development
Care for Child Development: an intervention in support of responsive caregiving and early child development
AbstractBackgroundAn estimated 43% of children younger than 5 years of age are at elevated risk of failing to achieve their human potential. In response, the World Health Organizat...

