Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Influence of the Slot on The Effusion Cooling Performance with the Simulated Swirling Flow

View through CrossRef
An experimental study was conducted to investigate the influence of the slot jet on the cooling performance of a slot-effusion combined cooling scheme with a simulated swirling flow of the lean-burn combustor. PIV (particle image velocimetry) results show the slot jet reshapes the large-scale vortex structure and changes the lift-up effect of effusion jets. PSP (pressure-sensitive paint) results show there is still a region lacking the coverage of the slot coolant with an active slot, and here adiabatic cooling effectiveness ηad decreases downstream of holes. This phenomenon is enhanced by the lower effusion pressure drop. Consequently, the laterally averaged ηad shows an increase of 27% in the downstream of effusion plate when ΔP= 3%. While for ΔP=1% and 2%, the introduction of slot jet leads to an unchanged or slightly declined laterally averaged ηad in the region of 40<x / D<60. Moreover, the slot jet inhibits the lift-up effect of effusion jets when ΔP=3% resulting in a maximum rise of 180.0% for the area-averaged ηad. PIV and PSP results indicate the importance of the match for the pressure drops of the slot jet ΔW and effusion jetsΔP. From the present study, the same pressure drop (3%) for slot and effusion jet shows better cooling performance.
Title: The Influence of the Slot on The Effusion Cooling Performance with the Simulated Swirling Flow
Description:
An experimental study was conducted to investigate the influence of the slot jet on the cooling performance of a slot-effusion combined cooling scheme with a simulated swirling flow of the lean-burn combustor.
PIV (particle image velocimetry) results show the slot jet reshapes the large-scale vortex structure and changes the lift-up effect of effusion jets.
PSP (pressure-sensitive paint) results show there is still a region lacking the coverage of the slot coolant with an active slot, and here adiabatic cooling effectiveness ηad decreases downstream of holes.
This phenomenon is enhanced by the lower effusion pressure drop.
Consequently, the laterally averaged ηad shows an increase of 27% in the downstream of effusion plate when ΔP= 3%.
While for ΔP=1% and 2%, the introduction of slot jet leads to an unchanged or slightly declined laterally averaged ηad in the region of 40<x / D<60.
Moreover, the slot jet inhibits the lift-up effect of effusion jets when ΔP=3% resulting in a maximum rise of 180.
0% for the area-averaged ηad.
PIV and PSP results indicate the importance of the match for the pressure drops of the slot jet ΔW and effusion jetsΔP.
From the present study, the same pressure drop (3%) for slot and effusion jet shows better cooling performance.

Related Results

Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Combustor Effusion Cooling Multiparameter Aerothermal Numerical Analysis
Combustor Effusion Cooling Multiparameter Aerothermal Numerical Analysis
The solid temperature prediction is one of the most widespread type of modelization used in the industry. One reading this study might wonder why there would be readymade solutions...
Impingement/Effusion Cooling With Low Coolant Mass Flow
Impingement/Effusion Cooling With Low Coolant Mass Flow
A low coolant mass flow impingement/effusion design for a low NOx combustor wall cooling application was predicted, using conjugate heat transfer (CHT) computational fluid dynamics...
Experimental Study on the Effects of Slot Jet on Film Cooling Performance in the Cascade Endwall With Purge Flow
Experimental Study on the Effects of Slot Jet on Film Cooling Performance in the Cascade Endwall With Purge Flow
Abstract Based on the infrared temperature measurement technology, in this paper, the effect of the purge flow from the upstream slot on the film cooling performance...
Swirling flow field reconstruction based on experimental observations using physics-informed neural network
Swirling flow field reconstruction based on experimental observations using physics-informed neural network
The design of thermal protection modules (such as film cooling) for combustion chambers requires a high-fidelity swirling flow field. Although numerical methods provide insights in...
The Effects of Strong-Weak Swirling Interaction on Emissions In a Multi- Nozzle Model Combustor
The Effects of Strong-Weak Swirling Interaction on Emissions In a Multi- Nozzle Model Combustor
A linearly three-nozzle rectangular model combustor is designed in this study to investigate the effects of strong-weak swirling interaction on emissions. The swirl number of the n...
Effects of Inlet Swirl on Endwall Film Cooling in Neighboring Vane Passages
Effects of Inlet Swirl on Endwall Film Cooling in Neighboring Vane Passages
The distribution of film cooling effectiveness of endwall film-cooling holes is considered to be periodic between neighboring high pressure turbine passages in most cascade experim...

Back to Top