Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Preliminary Observations Regarding Angiographic Pattern of Restenosis After Rapamycin-Eluting Stent Implantation

View through CrossRef
Background— Restenosis after implantation of drug-eluting stents (DES) is a rare phenomenon, occurring more frequently peri-stent. Methods and Results— We evaluated the pattern of restenosis occurring after implantation of DES in unselected lesions. From April 15 to December 6, 2002, we treated 368 patients with 735 lesions by using 841 rapamycin-eluting stents (Cypher, Cordis, a Johnson & Johnson Company). Mean baseline lesion length was 17.48±12.19 mm, and mean stent length was 27.59±14.02 mm. Follow-up ischemia-driven angiography was performed in 24 patients. Eleven patients had angiographic restenosis (≥50% diameter stenosis) in 14 stented segments (stent and 5 mm proximal and distal to the stent). The pattern of restenosis in all 14 stented segments was focal, and in 6 of them it was multifocal, occurring inside the stents. Mean length of restenotic lesions was 5.62±1.90 mm, with a range from 2.54 to 8.44 mm. One multifocal restenosis involved also the distal stent margin. Intravascular ultrasound evaluation at follow-up, performed in 2 patients, showed significant lumen obstruction attributable to in-stent hyperplasia in both cases. Individual cases can be viewed in the Data Supplement. Conclusions— The pattern of restenotic lesions after rapamycin-eluting stent implantation was focal and mostly inside the stent.
Title: Preliminary Observations Regarding Angiographic Pattern of Restenosis After Rapamycin-Eluting Stent Implantation
Description:
Background— Restenosis after implantation of drug-eluting stents (DES) is a rare phenomenon, occurring more frequently peri-stent.
Methods and Results— We evaluated the pattern of restenosis occurring after implantation of DES in unselected lesions.
From April 15 to December 6, 2002, we treated 368 patients with 735 lesions by using 841 rapamycin-eluting stents (Cypher, Cordis, a Johnson & Johnson Company).
Mean baseline lesion length was 17.
48±12.
19 mm, and mean stent length was 27.
59±14.
02 mm.
Follow-up ischemia-driven angiography was performed in 24 patients.
Eleven patients had angiographic restenosis (≥50% diameter stenosis) in 14 stented segments (stent and 5 mm proximal and distal to the stent).
The pattern of restenosis in all 14 stented segments was focal, and in 6 of them it was multifocal, occurring inside the stents.
Mean length of restenotic lesions was 5.
62±1.
90 mm, with a range from 2.
54 to 8.
44 mm.
One multifocal restenosis involved also the distal stent margin.
Intravascular ultrasound evaluation at follow-up, performed in 2 patients, showed significant lumen obstruction attributable to in-stent hyperplasia in both cases.
Individual cases can be viewed in the Data Supplement.
Conclusions— The pattern of restenotic lesions after rapamycin-eluting stent implantation was focal and mostly inside the stent.

Related Results

Predictors of insistent restenosis in patients undergoing percutaneous intervention
Predictors of insistent restenosis in patients undergoing percutaneous intervention
Coronary artery disease is one of the leading causes of morbidity and mortality worldwide. The first percutaneous coronary intervention was performed by Andreas Gruntzig on Septemb...
Crush Stenting With Paclitaxel-Eluting or Sirolimus-Eluting Stents for the Treatment of Coronary Bifurcation Lesions
Crush Stenting With Paclitaxel-Eluting or Sirolimus-Eluting Stents for the Treatment of Coronary Bifurcation Lesions
Two hundred forty-six patients with 252 bifurcation lesions were enrolled into a prospective, nonrandomized study to use paclitaxel-eluting or sirolimus-eluting stent for crush ste...
Clinical study of biodegradable polymer stent versus durable polymer stent in treating long coronary lesions
Clinical study of biodegradable polymer stent versus durable polymer stent in treating long coronary lesions
Objective This study compared the clinical efficacy and safety of homemade biodegradable polymer rapamycin-eluting stent (EXCEL TM) and durable polymer rapamycin-...
Six-Month Angiographic Outcome After Successful Repeat Percutaneous Intervention for In-Stent Restenosis
Six-Month Angiographic Outcome After Successful Repeat Percutaneous Intervention for In-Stent Restenosis
Background —In-stent restenosis is an increasing clinical problem. Discordant results have been published regarding the risk of recurrent restenosis after repeat angiop...
Incidence and Management of In-Stent Restenosis in Patients with Drug-Eluting Stents
Incidence and Management of In-Stent Restenosis in Patients with Drug-Eluting Stents
Introduction: The most prevalent complication of cardiac intervention is restenosis. After the BMS period, drug-eluting stents (DES) are the most suitable choice for stenosis treat...
Novel functionalized and patterned surfaces for cardiovascular applications
Novel functionalized and patterned surfaces for cardiovascular applications
Nowadays, cardiovascular diseases are mainly treated by implantation of a metallic or polymeric mesh, called stent, which maintains the artery widely open. This technique shows ver...

Back to Top