Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Automated decision support for Hallux Valgus treatment options using anteroposterior foot radiographs

View through CrossRef
BACKGROUND Assessment of the potential utility of deep learning with subsequent image analysis to automate the measurement of hallux valgus and intermetatarsal angles from radiographs to serve as a preoperative aid in establishing hallux valgus severity for clinical decision-making. AIM To investigate the accuracy of automated measurements of angles of hallux valgus from radiographs for further integration with the preoperative planning process. METHODS The data comprises 265 consecutive digital anteroposterior weightbearing foot radiographs. 181 radiographs were utilized for training (161) and validating (20) a U-Net neural network to achieve a mean Sørensen–Dice index > 97% on bone segmentation. 84 test radiographs were used for manual (computer assisted) and automated measurements of hallux valgus severity determined by hallux valgus (HVA) and intermetatarsal angles (IMA). The reliability of manual and computer-based measurements was calculated using the interclass correlation coefficient (ICC) and standard error of measurement (SEM). Inter- and intraobserver reliability coefficients were also compared. An operative treatment recommendation was then applied to compare results between automated and manual angle measurements. RESULTS Very high reliability was achieved for HVA and IMA between the manual measurements of three independent clinicians. For HVA, the ICC between manual measurements was 0.96-0.99. For IMA, ICC was 0.78-0.95. Comparing manual against automated computer measurement, the reliability was high as well. For HVA, absolute agreement ICC and consistency ICC were 0.97, and SEM was 0.32. For IMA, absolute agreement ICC was 0.75, consistency ICC was 0.89, and SEM was 0.21. Additionally, a strong correlation (0.80) was observed between our approach and traditional clinical adjudication for preoperative planning of hallux valgus, according to an operative treatment algorithm proposed by EFORT. CONCLUSION The proposed automated, artificial intelligence assisted determination of hallux valgus angles based on deep learning holds great potential as an accurate and efficient tool, with comparable accuracy to manual measurements by expert clinicians. Our approach can be effectively implemented in clinical practice to determine the angles of hallux valgus from radiographs, classify the deformity severity, streamline preoperative decision-making prior to corrective surgery.
Title: Automated decision support for Hallux Valgus treatment options using anteroposterior foot radiographs
Description:
BACKGROUND Assessment of the potential utility of deep learning with subsequent image analysis to automate the measurement of hallux valgus and intermetatarsal angles from radiographs to serve as a preoperative aid in establishing hallux valgus severity for clinical decision-making.
AIM To investigate the accuracy of automated measurements of angles of hallux valgus from radiographs for further integration with the preoperative planning process.
METHODS The data comprises 265 consecutive digital anteroposterior weightbearing foot radiographs.
181 radiographs were utilized for training (161) and validating (20) a U-Net neural network to achieve a mean Sørensen–Dice index > 97% on bone segmentation.
84 test radiographs were used for manual (computer assisted) and automated measurements of hallux valgus severity determined by hallux valgus (HVA) and intermetatarsal angles (IMA).
The reliability of manual and computer-based measurements was calculated using the interclass correlation coefficient (ICC) and standard error of measurement (SEM).
Inter- and intraobserver reliability coefficients were also compared.
An operative treatment recommendation was then applied to compare results between automated and manual angle measurements.
RESULTS Very high reliability was achieved for HVA and IMA between the manual measurements of three independent clinicians.
For HVA, the ICC between manual measurements was 0.
96-0.
99.
For IMA, ICC was 0.
78-0.
95.
Comparing manual against automated computer measurement, the reliability was high as well.
For HVA, absolute agreement ICC and consistency ICC were 0.
97, and SEM was 0.
32.
For IMA, absolute agreement ICC was 0.
75, consistency ICC was 0.
89, and SEM was 0.
21.
Additionally, a strong correlation (0.
80) was observed between our approach and traditional clinical adjudication for preoperative planning of hallux valgus, according to an operative treatment algorithm proposed by EFORT.
CONCLUSION The proposed automated, artificial intelligence assisted determination of hallux valgus angles based on deep learning holds great potential as an accurate and efficient tool, with comparable accuracy to manual measurements by expert clinicians.
Our approach can be effectively implemented in clinical practice to determine the angles of hallux valgus from radiographs, classify the deformity severity, streamline preoperative decision-making prior to corrective surgery.

Related Results

Incident rates of hallux valgus in female students college in Indonesia
Incident rates of hallux valgus in female students college in Indonesia
Problems and Purpose. Hallux valgus is a common foot deformity. Hallux valgus is more likely to occur in individuals who frequently wear shoes with pointed toes, as this footwear c...
Modified Chevron osteotomy for treatment of Hallux valgus
Modified Chevron osteotomy for treatment of Hallux valgus
Background And Objective:  Hallux valgus is the most common forefoot deformity in adults, especially in females. Almost 150 different procedures have been described for the treatme...
Analysis of Dynamic Angle of Gait and Radiographic Features in Subjects with Hallux Abducto Valgus and Hallux Limitus
Analysis of Dynamic Angle of Gait and Radiographic Features in Subjects with Hallux Abducto Valgus and Hallux Limitus
Background: Hallux abducto valgus and hallux limitus are two commonly encountered foot deformities causing altered structure and function of the first metatarsophalangeal joint and...

Back to Top