Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Effect of Swirl Gas Injection on Bubble Characteristics in a Bubble Column

View through CrossRef
Swirling gas injection is a well-known technique to improve mass transfer in bubble columns. It can be used to create small bubbles with a high surface area-to-volume ratio, which is beneficial for mass transfer. Swirl gas injection can also be used to create a more uniform bubble size distribution and improve the mixing of gas and liquid in the column. This study aims to determine the impact of swirl gas injection on bubble properties, including bubble shape, size, and velocity. A bubble detection approach has been developed for quick and precise determination of bubble size distributions in gas-liquid systems. Advanced digital image processing, including edge detection and bubble edge recognition, is used in this method. The experiment is conducted in a bubble column at a height of 57 cm and 61 cm. The column had a ring sparger and was made of Plexiglas. Tap water was used as the liquid, while air from an air compressor was utilized as the gas phase. The shape, size, population, and velocity of the bubble are measured using a high-speed digital camera. According to this study, the average bubble size reduced as the impeller speed increased, while the population of bubbles increased when the sparger rotation speed increased from 30 to 150 rpm.
Title: Effect of Swirl Gas Injection on Bubble Characteristics in a Bubble Column
Description:
Swirling gas injection is a well-known technique to improve mass transfer in bubble columns.
It can be used to create small bubbles with a high surface area-to-volume ratio, which is beneficial for mass transfer.
Swirl gas injection can also be used to create a more uniform bubble size distribution and improve the mixing of gas and liquid in the column.
This study aims to determine the impact of swirl gas injection on bubble properties, including bubble shape, size, and velocity.
A bubble detection approach has been developed for quick and precise determination of bubble size distributions in gas-liquid systems.
Advanced digital image processing, including edge detection and bubble edge recognition, is used in this method.
The experiment is conducted in a bubble column at a height of 57 cm and 61 cm.
The column had a ring sparger and was made of Plexiglas.
Tap water was used as the liquid, while air from an air compressor was utilized as the gas phase.
The shape, size, population, and velocity of the bubble are measured using a high-speed digital camera.
According to this study, the average bubble size reduced as the impeller speed increased, while the population of bubbles increased when the sparger rotation speed increased from 30 to 150 rpm.

Related Results

Rotordynamic Performance of a Negative-Swirl Brake for a Tooth-on-Stator Labyrinth Seal
Rotordynamic Performance of a Negative-Swirl Brake for a Tooth-on-Stator Labyrinth Seal
In the late 1970’s, Benckert and Wachter (Technical University Stuttgart) tested labyrinth seals using air as the test media and measured direct and cross-coupled stiffness coeffic...
The Canberra Bubble
The Canberra Bubble
According to the ABC television program Four Corners, “Parliament House in Canberra is a hotbed of political intrigue and high tension … . It’s known as the ‘Canberra Bubble’ and i...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Overview of Key Zonal Water Injection Technologies in China
Overview of Key Zonal Water Injection Technologies in China
Abstract Separated layer water injection is the important technology to realize the oilfield long-term high and stable yield. Through continuous researches and te...
Lectin C gene analysis v1
Lectin C gene analysis v1
Mammalian Tissue Total RNA Purification Protocol by GeneJET RNA Purification Kit (Thermo Scientific, USA) Before starting: • Supplement the required amount of Lysis Buffer with β-...
Atomization and mixing performance of swirl-venturi lean direct injection
Atomization and mixing performance of swirl-venturi lean direct injection
<p>This paper investigated the effects of swirl number and momentum ratio on the atomization and mixing performance of Swirl-Venturi Lean Direct Injection technology. Mie sca...
The Effect of Some Parameters on Behaviour and Bearing Capacity of Multi-Drum Stone Columns under Static Load and Earthquake
The Effect of Some Parameters on Behaviour and Bearing Capacity of Multi-Drum Stone Columns under Static Load and Earthquake
In this thesis, the effect of several important parameters on the behaviour and bearing capacity of multi-drum stone columns loaded by short-term static loads and earthquakes was i...

Back to Top