Javascript must be enabled to continue!
High resolution and high throughput bacteria separation from blood using elasto-inertial microfluidics
View through CrossRef
Abstract
Improved sample preparation has the potential to address a huge unmet need for fast turnaround sepsis tests that enable early administration of appropriate antimicrobial therapy. In recent years, inertial and elasto-inertial microfluidics-based sample preparation has gained substantial interest for bioparticle separation applications. However, for applications in blood stream infections the throughput and bacteria separation efficiency has thus far been limited. In this work, for the first time we report elasto-inertial microfluidics-based bacteria isolation from blood at throughputs and efficiencies unparalleled with current microfluidics-based state of the art. In the method, bacteria-spiked blood sample is prepositioned close to the outer wall of a spiral microchannel using a viscoelastic sheath buffer. The blood cells will remain fully focused throughout the length of the channel while bacteria migrate to the inner wall for effective separation. Initially, particles of different sizes were used to investigate particle focusing and the separation performance of the spiral device. A separation efficiency of 96% for the 1 µm particles was achieved, while 100% of 3 µm particles were recovered at the desired outlet at a high throughput of 1 mL/min. Following, processing blood samples revealed a minimum of 1:2 dilution was necessary to keep the blood cells fully focus at the outer wall. In experiments involving bacteria spiked in diluted blood, viable
E.coli
were continuously separated at a total flow rate of 1 mL/min, with an efficiency between 82 to 90% depending on the blood dilution. Using a single spiral, it takes 40 minutes to process 1 mL of blood at a separation efficiency of 82% and 3 hours at 90% efficiency. To the best of our knowledge, this is the highest blood sample throughput per single microfluidic chip reported for the corresponding separation efficiency. As such, the label-free, passive and high throughput bacteria isolation method has a great potential for speeding up downstream phenotypic and molecular analysis of bacteria.
Title: High resolution and high throughput bacteria separation from blood using elasto-inertial microfluidics
Description:
Abstract
Improved sample preparation has the potential to address a huge unmet need for fast turnaround sepsis tests that enable early administration of appropriate antimicrobial therapy.
In recent years, inertial and elasto-inertial microfluidics-based sample preparation has gained substantial interest for bioparticle separation applications.
However, for applications in blood stream infections the throughput and bacteria separation efficiency has thus far been limited.
In this work, for the first time we report elasto-inertial microfluidics-based bacteria isolation from blood at throughputs and efficiencies unparalleled with current microfluidics-based state of the art.
In the method, bacteria-spiked blood sample is prepositioned close to the outer wall of a spiral microchannel using a viscoelastic sheath buffer.
The blood cells will remain fully focused throughout the length of the channel while bacteria migrate to the inner wall for effective separation.
Initially, particles of different sizes were used to investigate particle focusing and the separation performance of the spiral device.
A separation efficiency of 96% for the 1 µm particles was achieved, while 100% of 3 µm particles were recovered at the desired outlet at a high throughput of 1 mL/min.
Following, processing blood samples revealed a minimum of 1:2 dilution was necessary to keep the blood cells fully focus at the outer wall.
In experiments involving bacteria spiked in diluted blood, viable
E.
coli
were continuously separated at a total flow rate of 1 mL/min, with an efficiency between 82 to 90% depending on the blood dilution.
Using a single spiral, it takes 40 minutes to process 1 mL of blood at a separation efficiency of 82% and 3 hours at 90% efficiency.
To the best of our knowledge, this is the highest blood sample throughput per single microfluidic chip reported for the corresponding separation efficiency.
As such, the label-free, passive and high throughput bacteria isolation method has a great potential for speeding up downstream phenotypic and molecular analysis of bacteria.
Related Results
High resolution bacterial separation from blood using elasto-inertial microfluidics
High resolution bacterial separation from blood using elasto-inertial microfluidics
Improved sample preparation has the potential to address a huge unmet
need for fast turnaround sepsis tests that enable early administration
of appropriate antimicrobial therapy. I...
High Throughput Viscoelastic Particle Focusing and Separation in Spiral Microchannels
High Throughput Viscoelastic Particle Focusing and Separation in Spiral Microchannels
Abstract
Passive particle manipulation using inertial and elasto-inertial microfluidics have received substantial interest in recent years and have found various applicatio...
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
[RETRACTED] Guardian Blood Balance Australia- Reviews - Guardian Botanicals Blood Balance [AU] SCAM ALERT! Read Real Critical Reports.. Price in Australia v1
[RETRACTED] Guardian Blood Balance Australia- Reviews - Guardian Botanicals Blood Balance [AU] SCAM ALERT! Read Real Critical Reports.. Price in Australia v1
[RETRACTED]Guardian Blood Balance Australia Reviews - Diabetes and blood sugar are some of the common problems that are attacking so many adult individuals nowadays. Obesity is t...
High resolution and rapid separation of bacteria from blood using elasto‐inertial microfluidics
High resolution and rapid separation of bacteria from blood using elasto‐inertial microfluidics
Abstract
Improved sample preparation has the potential to address unmet needs for fast turnaround sepsis tests. In this work, we report elast...
Inertial microfluidics: Recent advances
Inertial microfluidics: Recent advances
AbstractInertial microfluidics has attracted significant attentions in last decade due to its superior advantages of high throughput, label‐ and external field‐free operation, simp...
P-061 In situ microfluidics of fluidic walls: a novel deviceless and cost-effective approach for sperm selection in the same ICSI-dish
P-061 In situ microfluidics of fluidic walls: a novel deviceless and cost-effective approach for sperm selection in the same ICSI-dish
Abstract
Study question
Is our novel deviceless method based on in-situ microfluidics a valuable strategy to select suitable spe...
A review on inertial microfluidic fabrication methods
A review on inertial microfluidic fabrication methods
In recent decades, there has been significant interest in inertial microfluidics due to its high throughput, ease of fabrication, and no need for external forces. The focusing effi...

