THE VARIABILITY OF REPEATED MEASUREMENTS OF ARTERIAL STIFFNESS BIOMARKERS: A SHORT-TERM LONGITUDINAL STUDY IN A WIDE RANGE OF NORMOTENSIVE AND HYPERTENSIVE PARTICIPANTS
View through CrossRef
Objective:
Arterial stiffness (AS) biomarkers, such as pulse wave velocity and augmentation indices, are predictive of future cardiovascular events in subjects free of overt cardiovascular disease and are regarded as indicators of atherosclerosis and subclinical organ damage. As the surrogate endpoints of future cardiovascular events, they are emerging as an appealing therapeutic target. However, the variability of intrasubject measurements might hinder their use in clinical practice.
Design and method:
In this study, we estimate the reproducibility of intrasubject measurements of AS biomarkers: pulse wave velocity and central augmentation index, measured by oscillometry (Arteriograph) and applanation tonometry (SphygmoCor) devices. Thirty-six participants evenly distributed across different genders, BMI categories, ages, and hypertensive status were enrolled in the study. Participants visited the laboratory for three days, one week apart. On each visiting day, they came in the morning and afternoon (6 visits in total). All measurements were performed in accordance with the ARTERY society recommendations and in double by two operators who received the necessary training and performed measurements in a randomized order. Linear mixed models were used to analyze the nested data grouped by a participant and a visiting day.
Results:
Based on the interim analysis of 451 recordings that passed the quality control, we found that a device type and BMI category significantly affected pulse wave velocity in intrasubject measurements. As for the central augmentation index, it was a device and a time of the day (morning/afternoon) that affected its variability within a participant. An operator or interaction between an operator and a device did not affect measurements of these biomarkers.
Conclusions:
Since expected intersubject PWV variability due to different devices or BMI allows for differences to extend 10% of the observed population-based range, the identification of weak/moderately effective agents used in de-stiffening therapies might be hampered. For cAIx, this variability was somewhat less pronounced.
Ovid Technologies (Wolters Kluwer Health)
Title: THE VARIABILITY OF REPEATED MEASUREMENTS OF ARTERIAL STIFFNESS BIOMARKERS: A SHORT-TERM LONGITUDINAL STUDY IN A WIDE RANGE OF NORMOTENSIVE AND HYPERTENSIVE PARTICIPANTS
Description:
Objective:
Arterial stiffness (AS) biomarkers, such as pulse wave velocity and augmentation indices, are predictive of future cardiovascular events in subjects free of overt cardiovascular disease and are regarded as indicators of atherosclerosis and subclinical organ damage.
As the surrogate endpoints of future cardiovascular events, they are emerging as an appealing therapeutic target.
However, the variability of intrasubject measurements might hinder their use in clinical practice.
Design and method:
In this study, we estimate the reproducibility of intrasubject measurements of AS biomarkers: pulse wave velocity and central augmentation index, measured by oscillometry (Arteriograph) and applanation tonometry (SphygmoCor) devices.
Thirty-six participants evenly distributed across different genders, BMI categories, ages, and hypertensive status were enrolled in the study.
Participants visited the laboratory for three days, one week apart.
On each visiting day, they came in the morning and afternoon (6 visits in total).
All measurements were performed in accordance with the ARTERY society recommendations and in double by two operators who received the necessary training and performed measurements in a randomized order.
Linear mixed models were used to analyze the nested data grouped by a participant and a visiting day.
Results:
Based on the interim analysis of 451 recordings that passed the quality control, we found that a device type and BMI category significantly affected pulse wave velocity in intrasubject measurements.
As for the central augmentation index, it was a device and a time of the day (morning/afternoon) that affected its variability within a participant.
An operator or interaction between an operator and a device did not affect measurements of these biomarkers.
Conclusions:
Since expected intersubject PWV variability due to different devices or BMI allows for differences to extend 10% of the observed population-based range, the identification of weak/moderately effective agents used in de-stiffening therapies might be hampered.
For cAIx, this variability was somewhat less pronounced.
Related Results
Assessment of arterial stiffness in populations at increased cardiovascular risk
Assessment of arterial stiffness in populations at increased cardiovascular risk
<p dir="ltr">Introduction</p><p dir="ltr">Arterial stiffness is an established marker of cardiovascular risk. However, its full potential for clinical application...
Assessment of arterial stiffness in populations at increased cardiovascular risk
Assessment of arterial stiffness in populations at increased cardiovascular risk
<p dir="ltr">Introduction</p><p dir="ltr">Arterial stiffness is an established marker of cardiovascular risk. However, its full potential for clinical application...
Subclinical arterial stiffness in prehypertensives
Subclinical arterial stiffness in prehypertensives
Objective
To assess the difference of arterial stiffness in prehypertensive subjects in comparison to normotensive subjects.
...
RNA-sequencing analysis of differential gene expression associated with arterial stiffness
RNA-sequencing analysis of differential gene expression associated with arterial stiffness
Objectives
Arterial stiffness is recognized as an important predictor of cardiovascular disease morbidity and mortality, independent of traditional cardiovascul...
SERUM NITRIC OXIDE METABOLITE (NOX) LEVELS IN HYPERTENSIVE PATIENTS AT REST: A COMPARISON OF AGE, GENDER, BLOOD PRESSURE AND COMPLICATIONS USING NORMOTENSIVE CONTROLS
SERUM NITRIC OXIDE METABOLITE (NOX) LEVELS IN HYPERTENSIVE PATIENTS AT REST: A COMPARISON OF AGE, GENDER, BLOOD PRESSURE AND COMPLICATIONS USING NORMOTENSIVE CONTROLS
SUMMARY
Hypertensive patients have pathophysiological changes such as atherosclerosis, endothelial dysfunction and inflammations. The patients’ serum nitric oxide metabolite (nitr...
Arterial Stiffness Assessed by Cardio-Ankle Vascular Index
Arterial Stiffness Assessed by Cardio-Ankle Vascular Index
Arterial stiffness is an age-related disorder. In the medial layer of arteries, mechanical fracture due to fatigue failure for the pulsatile wall strain causes medial degeneration ...
HYPERTENSIVE CRISES: HYPERTENSIVE EMERGENCY AND CRISIS MANAGEMENT DURING ANESTHESIA
HYPERTENSIVE CRISES: HYPERTENSIVE EMERGENCY AND CRISIS MANAGEMENT DURING ANESTHESIA
Introduction: hypertensive crisis is characterized by an acute and massive increase in blood pressure. Hypertensive crises encompass several clinical situations with different seve...
COVID‐19 Increases Markers of Endothelial Damage in Normotensive Pregnant Women
COVID‐19 Increases Markers of Endothelial Damage in Normotensive Pregnant Women
COVID‐19 (CV19) is a disease caused by SARS‐CoV‐2 and has caused a pandemic since discovered in 2019, resulting in over 5 million deaths worldwide. The impact of CV19 on pregnancy ...