Management of high-energy tibial shaft fractures using the hexapod circular external fixator

View through CrossRef
Abstract Background The hexapod external fixator (HEF) is increasingly used for high-energy tibial shaft fracture care as more general orthopedic surgeons are gaining expertise of this versatile device. The purpose of this study was to evaluate the clinical effectiveness of the HEF for definitive management in patients with high-energy tibial shaft fractures. Methods The study was conducted on 34 patients with tibial shaft fractures who were admitted or referred to our institution and consented to HEF treatment from Jan 2016 to June 2019, including 27 males and 7 females with a mean age of 39 years (range 18 to 65 years). Patients' clinical and radiological data, and the final clinical outcomes at a minimum of 12 months follow-up were collected and retrospectively analyzed. All complications were documented according to Paley’s classification. The clinical outcomes were evaluated using the Association for the Study and Application of the Method of Ilizarov criteria (ASAMI) at the last clinical visit. Results All patients remained in the HEF for a mean of 26 weeks (range 15 to 52 weeks) and acquired complete bone union. The satisfactory alignment was achieved in all patients, and all the patients were able to perform daily activities with no difficulty at the last clinical visit. Complications included pin tract infection (44%), delayed union (6%), nonunion (3%), and joint stiffness (3%). The ASAMI bony result was excellent in 31 patients and good in 3. The ASAMI functional result was excellent in 27 patients, good in 6, and fair in 1. Conclusions Definitive management using the hexapod external fixator is an alternative and effective method for high-energy tibial shaft fractures, including technical advantages of early trauma-control, the versatility of achieving excellent alignment, and the continuity of device until bone union.
Title: Management of high-energy tibial shaft fractures using the hexapod circular external fixator
Description:
Abstract Background The hexapod external fixator (HEF) is increasingly used for high-energy tibial shaft fracture care as more general orthopedic surgeons are gaining expertise of this versatile device.
The purpose of this study was to evaluate the clinical effectiveness of the HEF for definitive management in patients with high-energy tibial shaft fractures.
Methods The study was conducted on 34 patients with tibial shaft fractures who were admitted or referred to our institution and consented to HEF treatment from Jan 2016 to June 2019, including 27 males and 7 females with a mean age of 39 years (range 18 to 65 years).
Patients' clinical and radiological data, and the final clinical outcomes at a minimum of 12 months follow-up were collected and retrospectively analyzed.
All complications were documented according to Paley’s classification.
The clinical outcomes were evaluated using the Association for the Study and Application of the Method of Ilizarov criteria (ASAMI) at the last clinical visit.
Results All patients remained in the HEF for a mean of 26 weeks (range 15 to 52 weeks) and acquired complete bone union.
The satisfactory alignment was achieved in all patients, and all the patients were able to perform daily activities with no difficulty at the last clinical visit.
Complications included pin tract infection (44%), delayed union (6%), nonunion (3%), and joint stiffness (3%).
The ASAMI bony result was excellent in 31 patients and good in 3.
The ASAMI functional result was excellent in 27 patients, good in 6, and fair in 1.
Conclusions Definitive management using the hexapod external fixator is an alternative and effective method for high-energy tibial shaft fractures, including technical advantages of early trauma-control, the versatility of achieving excellent alignment, and the continuity of device until bone union.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
FRACTURES OF THE TIBIAL COLUMN (FCT), FRACTURES OF THE TIBIAL EMINENCE OR INTERCONDYLAR EMINENCE
FRACTURES OF THE TIBIAL COLUMN (FCT), FRACTURES OF THE TIBIAL EMINENCE OR INTERCONDYLAR EMINENCE
Introduction: Tibial spine fractures (TSCF), also called tibial eminence or intercondylar eminence fractures, are defined as bony or chondral avulsions of the tibial plateau at the...
Tosic External Fixator in the Management of Proximal Tibial Fractures in Adults
Tosic External Fixator in the Management of Proximal Tibial Fractures in Adults
ABSTRACT This retrospective clinical study assessed proximal tibial fractures managed with the Tosic external fixator. Nineteen patients with 21 proximal tibial fractures...
TIBIAL DIAPHYSEAL FRACTURE, PANORAMIC REVISION
TIBIAL DIAPHYSEAL FRACTURE, PANORAMIC REVISION
Introduction: Tibial fractures are quite common injuries. Since the tibia has a subcutaneous location, it is more likely to show exposed fractures. Exposed fractures of the tibial ...

Back to Top