Comparison of Optical Quality and Distinct Macular Thickness in Femtosecond Laser-Assisted versus Phacoemulsification Cataract Surgery

View through CrossRef
Abstract Background: Optical quality and macular thickness changing optical quality is rarely reported after femtosecond laser-assisted cataract surgery (FLACS). In current research, we evaluated optical quality recovery and distinct macular thickness changes after FLACS and phacoemulsification cataract surgery (PCS). Methods: A total of 100 cataract patients (100 eyes) were included (50 eyes for the FLACS group and 50 eyes for the PCS group). Modulation transfer function (MTF), point spread function (PSF) and dysfunctional lens index (DLI) were measured by a ray-tracing aberrometer (iTrace). Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were also assessed pre-operation,1 week and 1 month after surgery. The MTF values at spatial frequencies of 5, 10, 15, 20, 25 and 30 cycles/degree (c/d) were selected. We used optical coherence tomography (OCT) to assess the macular thickness of different regions pre-operatively and1month after the surgery. Results: In PCS group, we found the statistically significant differences between pre-operation and post-operation in DLI ( p <0.0001), PSF (strehl ratio, SR) ( p= 0.027) and MTF ( p =0.028), but not intraocular pressure (IOP) ( p =0.857). The differences between pre-operation and post-operation for DLI ( p =0.031), SR ( p =0.01) and IOP ( p =0.03), but not MTF ( p =0.128) were also found in FLACS group. The differences were statistically significant when the spatial frequencies were at 5, 10 and 25 ( p =0.013, 0.031 and 0.048) between pre-operation and post-operation in PCS group but not FLACS group at 1month. In PCS group, we found the differences between pre-operation and post-operation in nasal inter macular ring thickness (NIMRT) ( p =0.03), foveal volume (FV) ( p =0.034) and average retinal thickness (ART) ( p =0.025) but not FLACS group at 1month. Conclusion: FLACS is safe that did not cause significant increase of macular thickness in current study. However, it also cannot produce better optical quality. In contrast, PCS can produce macular thickness changes, but better optical quality recovery. The slightly retinal change may not affect optical quality.
Title: Comparison of Optical Quality and Distinct Macular Thickness in Femtosecond Laser-Assisted versus Phacoemulsification Cataract Surgery
Description:
Abstract Background: Optical quality and macular thickness changing optical quality is rarely reported after femtosecond laser-assisted cataract surgery (FLACS).
In current research, we evaluated optical quality recovery and distinct macular thickness changes after FLACS and phacoemulsification cataract surgery (PCS).
Methods: A total of 100 cataract patients (100 eyes) were included (50 eyes for the FLACS group and 50 eyes for the PCS group).
Modulation transfer function (MTF), point spread function (PSF) and dysfunctional lens index (DLI) were measured by a ray-tracing aberrometer (iTrace).
Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were also assessed pre-operation,1 week and 1 month after surgery.
The MTF values at spatial frequencies of 5, 10, 15, 20, 25 and 30 cycles/degree (c/d) were selected.
We used optical coherence tomography (OCT) to assess the macular thickness of different regions pre-operatively and1month after the surgery.
Results: In PCS group, we found the statistically significant differences between pre-operation and post-operation in DLI ( p <0.
0001), PSF (strehl ratio, SR) ( p= 0.
027) and MTF ( p =0.
028), but not intraocular pressure (IOP) ( p =0.
857).
The differences between pre-operation and post-operation for DLI ( p =0.
031), SR ( p =0.
01) and IOP ( p =0.
03), but not MTF ( p =0.
128) were also found in FLACS group.
The differences were statistically significant when the spatial frequencies were at 5, 10 and 25 ( p =0.
013, 0.
031 and 0.
048) between pre-operation and post-operation in PCS group but not FLACS group at 1month.
In PCS group, we found the differences between pre-operation and post-operation in nasal inter macular ring thickness (NIMRT) ( p =0.
03), foveal volume (FV) ( p =0.
034) and average retinal thickness (ART) ( p =0.
025) but not FLACS group at 1month.
Conclusion: FLACS is safe that did not cause significant increase of macular thickness in current study.
However, it also cannot produce better optical quality.
In contrast, PCS can produce macular thickness changes, but better optical quality recovery.
The slightly retinal change may not affect optical quality.

Related Results

The impact of cataract surgery on tear film physiology: signs and symptoms, progression and treatment
The impact of cataract surgery on tear film physiology: signs and symptoms, progression and treatment
PurposeThis study aimed to revise data published in the literature on the effects of cataract surgery on tear film characteristics, in relation to personal clinical surgical experi...
Femtosecond laser LenSx–assisted phacoemulsification of mature intumescent cataract
Femtosecond laser LenSx–assisted phacoemulsification of mature intumescent cataract
Background: Phacoemulsification (phaco) of mature intumescent cataract is one of the most difficult to perform anterior eye surgeries. In mature intumescent cataract phaco, the mos...
Macular oedema after uncomplicated phacoemulsification
Macular oedema after uncomplicated phacoemulsification
Background: Recent development of cataract surgery has led to the improvement of visual outcomes. However, pseudophakic cystoid macular oedema (CME), which is also known as Irvine–...
<b>Corneal Biomechanical Integrity After Femtosecond Laser-Assisted Versus Manual Incisions in Cataract Surgery: A Systematic Review</b>
<b>Corneal Biomechanical Integrity After Femtosecond Laser-Assisted Versus Manual Incisions in Cataract Surgery: A Systematic Review</b>
Background: The integrity of the clear corneal incision is fundamental to safety, wound sealing, and refractive stability in cataract surgery. Although femtosecond laser-assisted c...
Phacoemulsification in trabeculectomized eyes
Phacoemulsification in trabeculectomized eyes
Abstract.Purpose:  To evaluate retrospectively risk indicators for cataract surgery and the effect of phacoemulsification on intraocular pressure (IOP) control in eyes that have u...
Changes in central macular thickness before and after cataract surgery evaluated by optical coherence tomography in non-diabetic patient
Changes in central macular thickness before and after cataract surgery evaluated by optical coherence tomography in non-diabetic patient
Background: Optical coherence tomography (OCT) has been useful for objectively observing central macular thickness (CMT) changes inpre-operative and post-operative uneventful catar...

Back to Top