Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Engineered 3D-printed poly(vinyl alcohol) vascular grafts: Impact of thermal treatment and functionalization

View through CrossRef
Cardiovascular diseases, a leading cause of global mortality, are driving increased demand for artificial blood vessels for surgical repair. This study discloses the fabrication of three-dimensional (3D)-printed small blood vessels as tissue-engineered grafts. Large-diameter artery and vein grafts are readily available in the market, but small-diameter blood vessels face issues due to the lack of suitable materials. Lysine-biofunctionalized and unmodified poly(vinyl alcohol) grafts (PVA grafts) (2 mm inner diameter and 3 mm outer diameter) suitable for veins and venules were designed using Fusion 360 software, Autodesk Fusion. The PVA channels were fabricated from the 3D virtual model through fused deposition modeling using a PVA filament. These channels underwent thermal treatment to adjust their crystallinity, chemical crosslinking, and functionalization to optimize their mechanical properties and biocompatibility. Crosslinking and biofunctionalization were assessed using Fourier-transform infrared spectroscopy with attenuated total reflectance, while X-ray diffraction and differential scanning calorimetry were utilized for structural analysis. PVA grafts were biologically tested using three specific types of cell cultures: bEnd.3 brain endothelial cells, L929 fibroblast cells, and U937 monocyte-like cells. The hemocompatibility of the optimized vascular grafts was evaluated using horse blood, following the guidelines outlined in ASTM F756-13 Standard Practice for Assessment of Hemolytic Properties of Materials. The direct method for hemoglobin determination was specifically employed. Additionally, we developed an external polyethylene terephthalate glycol (PETG) 3D-printed platform to house the PVA grafts in parallel. The assembled platform (PETG and PVA graft) was connected to both an inlet and an outlet to facilitate the passage of an aqueous flow through the internal section of the PVA grafts during a flow test conducted under simulated body conditions (vacuum and blood pressure: 40 mbar). The flow was induced by a vacuum pump connected to the outlet of the platform, while the inlet was connected to a feeding glass. In summation, we have established a suitable protocol for producing small vascular grafts and demonstrated that the optimization process could significantly affect graft properties.
Title: Engineered 3D-printed poly(vinyl alcohol) vascular grafts: Impact of thermal treatment and functionalization
Description:
Cardiovascular diseases, a leading cause of global mortality, are driving increased demand for artificial blood vessels for surgical repair.
This study discloses the fabrication of three-dimensional (3D)-printed small blood vessels as tissue-engineered grafts.
Large-diameter artery and vein grafts are readily available in the market, but small-diameter blood vessels face issues due to the lack of suitable materials.
Lysine-biofunctionalized and unmodified poly(vinyl alcohol) grafts (PVA grafts) (2 mm inner diameter and 3 mm outer diameter) suitable for veins and venules were designed using Fusion 360 software, Autodesk Fusion.
The PVA channels were fabricated from the 3D virtual model through fused deposition modeling using a PVA filament.
These channels underwent thermal treatment to adjust their crystallinity, chemical crosslinking, and functionalization to optimize their mechanical properties and biocompatibility.
Crosslinking and biofunctionalization were assessed using Fourier-transform infrared spectroscopy with attenuated total reflectance, while X-ray diffraction and differential scanning calorimetry were utilized for structural analysis.
PVA grafts were biologically tested using three specific types of cell cultures: bEnd.
3 brain endothelial cells, L929 fibroblast cells, and U937 monocyte-like cells.
The hemocompatibility of the optimized vascular grafts was evaluated using horse blood, following the guidelines outlined in ASTM F756-13 Standard Practice for Assessment of Hemolytic Properties of Materials.
The direct method for hemoglobin determination was specifically employed.
Additionally, we developed an external polyethylene terephthalate glycol (PETG) 3D-printed platform to house the PVA grafts in parallel.
The assembled platform (PETG and PVA graft) was connected to both an inlet and an outlet to facilitate the passage of an aqueous flow through the internal section of the PVA grafts during a flow test conducted under simulated body conditions (vacuum and blood pressure: 40 mbar).
The flow was induced by a vacuum pump connected to the outlet of the platform, while the inlet was connected to a feeding glass.
In summation, we have established a suitable protocol for producing small vascular grafts and demonstrated that the optimization process could significantly affect graft properties.

Related Results

Problematyka wczesnego alkoholizmu
Problematyka wczesnego alkoholizmu
The Problem of Early Alcoholizm   The group of 50 repeatedly convicted recidivists, dealt with in this article, aged 38 on the average, deserves particular attention, first of all ...
Flight Safety - Alcohol Detection assisted by AI Facial Recognition Technology
Flight Safety - Alcohol Detection assisted by AI Facial Recognition Technology
The Federal Aviation Administration’s (FAA) “Bottle to Throttle” rule requires that a pilot may not use alcohol within 8 hours of a flight and cannot have a blood alcohol content a...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Alcohol consumption and risky sexual behaviors among fishers in Elmina in Ghana
Alcohol consumption and risky sexual behaviors among fishers in Elmina in Ghana
AbstractBackgroundAlcohol consumption is part of human social behavior and constitutes a routine part of social life in many countries. Prior studies have found over-indulgence of ...
Vascular Grafts and Flow-through Flaps for Microsurgical Lower Extremity Reconstruction
Vascular Grafts and Flow-through Flaps for Microsurgical Lower Extremity Reconstruction
Background The use of vascular grafts is indicated in case of insufficient pedicle length or for complex defects involving both soft tissues and vessels. Venous grafts (for both ve...
Monoterpene Content of Healthy Sand Pine and Sand Pine with Root Disease
Monoterpene Content of Healthy Sand Pine and Sand Pine with Root Disease
Abstract Graft combinations with slash pine ( Pinus elliottii Engelm.) alone and with sand pine ( ...
Cross‐country comparison of proportion of alcohol consumed in harmful drinking occasions using the International Alcohol Control Study
Cross‐country comparison of proportion of alcohol consumed in harmful drinking occasions using the International Alcohol Control Study
AbstractIntroduction and AimsThis study examines the proportion of alcohol markets consumed in harmful drinking occasions in a range of high‐, middle‐income countries and assesses ...

Back to Top