Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Refrigerant Subcooling Correlations for Different Expansion Devices for a Non-Intrusive Charge Indicator

View through CrossRef
The most common problems affecting residential and light commercial heating, ventilation, and air-conditioning (HVAC) systems are slow refrigerant leaks. Equipment users are usually not aware of the problem until most of the refrigerant has escaped. A low-cost, non-intrusive refrigerant charge indicator has been developed, based on temperature measurements and correlations formed to interpret the measured temperatures. It can be used to provide real time warnings to the equipment users before the majority of refrigerant is escaped. It could be inexpensive and easy to incorporate into existing heat pumps and air conditioners. Extensive laboratory experimental work was performed on a 2-ton window air conditioner and on a 2.5 ton split heat pump system. It was found that the heat pump was not sensitive to slow refrigerant leak because of the long liquid line. Liquid subcooling was measured to determine the system charge status before a substantial amount of refrigerant was leaked. This study reports the finding of correlations formed for liquid subcooling for the orifice plate and thermal expansion valve used on the heat pump system for both heating and cooling mode operation.
Title: Refrigerant Subcooling Correlations for Different Expansion Devices for a Non-Intrusive Charge Indicator
Description:
The most common problems affecting residential and light commercial heating, ventilation, and air-conditioning (HVAC) systems are slow refrigerant leaks.
Equipment users are usually not aware of the problem until most of the refrigerant has escaped.
A low-cost, non-intrusive refrigerant charge indicator has been developed, based on temperature measurements and correlations formed to interpret the measured temperatures.
It can be used to provide real time warnings to the equipment users before the majority of refrigerant is escaped.
It could be inexpensive and easy to incorporate into existing heat pumps and air conditioners.
Extensive laboratory experimental work was performed on a 2-ton window air conditioner and on a 2.
5 ton split heat pump system.
It was found that the heat pump was not sensitive to slow refrigerant leak because of the long liquid line.
Liquid subcooling was measured to determine the system charge status before a substantial amount of refrigerant was leaked.
This study reports the finding of correlations formed for liquid subcooling for the orifice plate and thermal expansion valve used on the heat pump system for both heating and cooling mode operation.

Related Results

Advanced Dual Refrigerant Expansion Cycle for Liquefaction
Advanced Dual Refrigerant Expansion Cycle for Liquefaction
Abstract This paper presents a LNG Liquefaction cycle configuration using two stages of methane expansion and a single stage of nitrogen expansion (Dual Refrigerant)...
Advanced Liquefaction Cycle for Natural Gas
Advanced Liquefaction Cycle for Natural Gas
This paper presents a LNG Liquefaction cycle configuration using two stages of methane expansion and a single stage of nitrogen expansion (Dual Refrigerant) to improve the efficien...
Air-Conditioning Using Waste Heat Energy
Air-Conditioning Using Waste Heat Energy
Abstract All oil & gas building facilities such as control room, electrical room, substation and personal accommodation etc., require a comfortable indoor condit...
Application and Exploration of Carbon Dioxide R744 as Refrigerant and Secondary Refrigerant in Refrigerating Unit of Commercial Super
Application and Exploration of Carbon Dioxide R744 as Refrigerant and Secondary Refrigerant in Refrigerating Unit of Commercial Super
In this paper, the cascade refrigeration system and the load cooling system of the natural working medium are integrated as one unit system, which can meet the needs of different t...
Hybrid system development and application research for refrigerant leak inspection
Hybrid system development and application research for refrigerant leak inspection
Recently, record-breaking heatwaves due to global warming and abnormal weather have occurred in the summer, and sales and usage of air conditioners are rapidly increasing. Air co...
Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
The present work includes design, construction and operates of a prototype solar absorption refrigeration system, using methanol as a refrigerant to avoid any refrigerant that caus...
Correlations Developed To Predict Two Phase Flow Through Wellhead Chokes
Correlations Developed To Predict Two Phase Flow Through Wellhead Chokes
Abstract The predictive accuracy of eight critical two-phase flow correlations aretested against field measured production data, from 210 well tests, coveringbroa...
Flow Assurance Aspects of Intrusive Erosion Probes
Flow Assurance Aspects of Intrusive Erosion Probes
Abstract Sand erosion in subsea components and pipelines can cause serious design and production problems. Erosion is a complex process that is affected by numero...

Back to Top