Javascript must be enabled to continue!
Effects of disc speed and height of flow mechanism of a solid manure spreader on uniformity of spreading and swath width
View through CrossRef
The aim of this study was to investigate the effects of disc speed and height of flow mechanism of a solid manure spreader in order to maintain uniformity of spread and swath width for optimum crop growth. The study was done using complete randomized design with three factors considered: tractor forward speed, height of flow mechanism (broadcasters) gate opening rates, (15, 30, 45cm) and disc speed (150, 300, 450rpm) applied according to SAE S341.2, 1999 test code. Results obtained and compared with an imported spreader shows that the developed spreader recorded the highest application rate of 4082.1kg/ha against that of the imported spreader of 1875.3kg/ha while the swath width was 9.5m compared to 9.0m of the imported. Results obtained also shows that the spreader gave a more uniform spread pattern of manure at a lower openning of 15cm height of flow mechanism and lesser disc speed of 150rpm. Disc speed and height of flow mechanism were found to be the major determining factor influencing spreading uniformity and swath width of cow dung manure for optimum crop growth.
African Journals Online (AJOL)
Title: Effects of disc speed and height of flow mechanism of a solid manure spreader on uniformity of spreading and swath width
Description:
The aim of this study was to investigate the effects of disc speed and height of flow mechanism of a solid manure spreader in order to maintain uniformity of spread and swath width for optimum crop growth.
The study was done using complete randomized design with three factors considered: tractor forward speed, height of flow mechanism (broadcasters) gate opening rates, (15, 30, 45cm) and disc speed (150, 300, 450rpm) applied according to SAE S341.
2, 1999 test code.
Results obtained and compared with an imported spreader shows that the developed spreader recorded the highest application rate of 4082.
1kg/ha against that of the imported spreader of 1875.
3kg/ha while the swath width was 9.
5m compared to 9.
0m of the imported.
Results obtained also shows that the spreader gave a more uniform spread pattern of manure at a lower openning of 15cm height of flow mechanism and lesser disc speed of 150rpm.
Disc speed and height of flow mechanism were found to be the major determining factor influencing spreading uniformity and swath width of cow dung manure for optimum crop growth.
Related Results
Composting for Feedlot Manure Management and Soil Quality
Composting for Feedlot Manure Management and Soil Quality
Contemporary industrialized grain and livestock production is Characterized by efficient, large‐scale confined animal feedlot operations (CAFOs) and equally efficient and large‐sca...
Development and Performance Evaluation of a Tractor Powered Solid Manure Spreader
Development and Performance Evaluation of a Tractor Powered Solid Manure Spreader
The objective of this study is to develop a tractor-powered manure spreader for various types of manure to facilitate manure spreading operation, reduce human drudgery and improve ...
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
<span style="font-size:11pt"><span style="background:#f9f9f4"><span style="line-height:normal"><span style="font-family:Calibri,sans-serif"><b><spa...
Understanding the management practices of animal manure and associated risks of transference of bacterial pathogens to crop vegetables
Understanding the management practices of animal manure and associated risks of transference of bacterial pathogens to crop vegetables
Manure is commonly used in agricultural production in Mauritius,but little is documented on the local management practices. Animal manure, in particular,is a live...
A comparison study of insertion of spreader graft in the convex side in patients with deviated nose undergoing open septorhinoplasty
A comparison study of insertion of spreader graft in the convex side in patients with deviated nose undergoing open septorhinoplasty
Background: Correction of a crooked or deviated nose is a major challenge for rhinoplasty surgeons. In the present study we proposed to compare the aesthetic and functional results...
Increased life expectancy of heart failure patients in a rural center by a multidisciplinary program
Increased life expectancy of heart failure patients in a rural center by a multidisciplinary program
Abstract
Funding Acknowledgements
Type of funding sources: None.
INTRODUCTION Patients with heart failure (HF)...
Hibernia Swath Bathymetry Field Survey
Hibernia Swath Bathymetry Field Survey
ABSTRACT
As a result of reservoir and drilling considerations, the decision was made to investigate alternate gravity base structure (GBS) sites for Hibernia. Pre...
Anaerobically Digested Cattle Manure Supplied More Nitrogen with Less Phosphorus Accumulation than Undigested Manure
Anaerobically Digested Cattle Manure Supplied More Nitrogen with Less Phosphorus Accumulation than Undigested Manure
Core Ideas
Barley recovered 19% of N applied by anaerobically digested cattle manure over 4 yr.
Barley recovered 10% of N applied by undigested cattle manure over 4 yr.
Separated s...