Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Moisture Mitigation Using a Vented Liner and a Vented Socket System for Individuals with Transfemoral Amputation

View through CrossRef
Abstract Sweating and heat buildup at the skin-liner interface is a major challenge for amputees. Liners made of heat-non-conducting materials cause sweating of the residual limb and may result in liners slipping off the skin surface, causing skin breakdown and affecting limb health. To address this, we evaluated the efficacy of the vented liner-socket system (VS, Össur) compared to Seal-In silicone liner and non-vented socket (nVS, Össur) in reducing relative humidity (RH) during increased perspiration. Nine amputees using nVS were randomized to VS or nVS in a 20-minute treadmill walk. RH was significantly attenuated (p < 0.0002) and perceived sweating improved (p < 0.05) with VS, patient-reported CLASS outcomes to determine the suspension, stability, comfort, and appearance were not significantly different between VS and nVS. There are limited rigorous scientific studies that clearly provide evidence-based guidelines to the prosthetist in the selection of liners from numerous available options. The present study is innovative in clearly establishing objective measures for assessing humidity and temperatures at the skin-liner interface while performing activity. This study provided maiden evidence that relative humidity at the skin-liner interface is reduced with the use of a vented liner-socket system when compared to a similar non-vented system.
Title: Moisture Mitigation Using a Vented Liner and a Vented Socket System for Individuals with Transfemoral Amputation
Description:
Abstract Sweating and heat buildup at the skin-liner interface is a major challenge for amputees.
Liners made of heat-non-conducting materials cause sweating of the residual limb and may result in liners slipping off the skin surface, causing skin breakdown and affecting limb health.
To address this, we evaluated the efficacy of the vented liner-socket system (VS, Össur) compared to Seal-In silicone liner and non-vented socket (nVS, Össur) in reducing relative humidity (RH) during increased perspiration.
Nine amputees using nVS were randomized to VS or nVS in a 20-minute treadmill walk.
RH was significantly attenuated (p < 0.
0002) and perceived sweating improved (p < 0.
05) with VS, patient-reported CLASS outcomes to determine the suspension, stability, comfort, and appearance were not significantly different between VS and nVS.
There are limited rigorous scientific studies that clearly provide evidence-based guidelines to the prosthetist in the selection of liners from numerous available options.
The present study is innovative in clearly establishing objective measures for assessing humidity and temperatures at the skin-liner interface while performing activity.
This study provided maiden evidence that relative humidity at the skin-liner interface is reduced with the use of a vented liner-socket system when compared to a similar non-vented system.

Related Results

Development of an Expandable Liner-Hanger System To Improve Reliability of Liner Installations
Development of an Expandable Liner-Hanger System To Improve Reliability of Liner Installations
Abstract Liner hangers and liner-top packers are commonly used in the oil field in various liner applications. Unfortunately, in the traditional systems that empl...
Optimal Configuration of a Double Liner System Including a Geomembrane Liner and a Composite Liner
Optimal Configuration of a Double Liner System Including a Geomembrane Liner and a Composite Liner
A number of landfills are designed with a double liner system that includes a geomembrane liner and a composite liner. The design engineer must select which of these two liners sho...
Case Histories: Liner-Completion Difficulties Resolved With Expandable Liner-Top Technology
Case Histories: Liner-Completion Difficulties Resolved With Expandable Liner-Top Technology
Abstract Typically, Liner-hanger systems have relied upon the primary cement job to provide sealing of the liner/casing overlap. Liner top packers have been run e...
Study on friction behavior at the interface between prosthetic socket and liner
Study on friction behavior at the interface between prosthetic socket and liner
Purpose: The friction characteristics at the interface between prosthetic socket and liner have an important influence on the walking function and wearing comfort of amputees. The ...
Dynamic model of closure the liner
Dynamic model of closure the liner
Annotation Purpose. Develop analytical dependences for modeling the speed and dynamics of deformation of liner depending on its design parameters and physical and mechanical charac...
Deployment of Liner Systems in Extreme High Mud Weight Environments in Gas Wells
Deployment of Liner Systems in Extreme High Mud Weight Environments in Gas Wells
Abstract During the development phase of a gas field, the abnormal pressure in a dolomitic limestone formation demanded an extremely high mud weight to control the w...
The frequency and Risk Factors of Re-amputation in Diabetic Foot Disease at a tertiary care hospital.
The frequency and Risk Factors of Re-amputation in Diabetic Foot Disease at a tertiary care hospital.
Introduction: The prevalence of diabetes in Pakistan is 11.7% and the preva-lence of diabetic foot in Pakistan is 13.9% with amputation rate of as high as 48%. Re-amputation carrie...

Back to Top