Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

New, Minimally Invasive, Anteromedial-Distal Approach for Plate Osteosynthesis of Distal-Third Humeral Shaft Fractures

View through CrossRef
Background: Fractures of the distal third of the humeral shaft remain a challenge today. Plate osteosynthesis is the most commonly used method of treatment. Current minimally invasive plate osteosynthesis (MIPO) techniques applied to the distal part of the humerus have shown a high risk of radial nerve injury, and they are unable to adequately fix distal-most fractures. Our hypothesis was that using a new MIPO approach, distal humeral shaft fractures can be safely fixed. The aim of this study was to develop this new anteromedial-distal MIPO approach. Methods: We conducted a laboratory descriptive study using 16 arms from adult human specimens. A new anteromedial-distal MIPO approach, starting distally through a small window in the pronator teres muscle, was developed. A premolded plate was introduced in the anterior side of the medial epicondylar area, through the anterior face of the humerus, up to the proximal part of the humeral shaft. Several anatomical parameters were measured on dissection to define the distances of the plate and screws to the neurovascular structures that could be at risk. Results: The radial nerve was not at risk because of its pathway through the posterior and lateral aspects of the arm. The mean distance from the most distal border of the medial epicondyle to the proximal border of the coronoid fossa was 3.36 cm (95% confidence interval [CI], 3.23 to 3.50 cm). At least 3 screws could be inserted in all specimens in this area and up to 5 when the fixation area was extended 2 cm proximally. The mean width of the medial epicondylar area was 2.19 cm (95% CI, 2.03 to 2.33 cm), space enough for the distal fixation of the plate. The ulnar nerve was at risk only from the tip of the most distal screw (mean distance of 2.50 mm; 95% CI, 1.60 to 3.40 mm) in specimens with a very narrow medial epicondylar area. Conclusions: This approach provides adequate fixation for distal humeral shaft fractures, but proper clinical studies must be undertaken. Clinical Relevance: This new approach avoids the risk of radial nerve injury.
Title: New, Minimally Invasive, Anteromedial-Distal Approach for Plate Osteosynthesis of Distal-Third Humeral Shaft Fractures
Description:
Background: Fractures of the distal third of the humeral shaft remain a challenge today.
Plate osteosynthesis is the most commonly used method of treatment.
Current minimally invasive plate osteosynthesis (MIPO) techniques applied to the distal part of the humerus have shown a high risk of radial nerve injury, and they are unable to adequately fix distal-most fractures.
Our hypothesis was that using a new MIPO approach, distal humeral shaft fractures can be safely fixed.
The aim of this study was to develop this new anteromedial-distal MIPO approach.
Methods: We conducted a laboratory descriptive study using 16 arms from adult human specimens.
A new anteromedial-distal MIPO approach, starting distally through a small window in the pronator teres muscle, was developed.
A premolded plate was introduced in the anterior side of the medial epicondylar area, through the anterior face of the humerus, up to the proximal part of the humeral shaft.
Several anatomical parameters were measured on dissection to define the distances of the plate and screws to the neurovascular structures that could be at risk.
Results: The radial nerve was not at risk because of its pathway through the posterior and lateral aspects of the arm.
The mean distance from the most distal border of the medial epicondyle to the proximal border of the coronoid fossa was 3.
36 cm (95% confidence interval [CI], 3.
23 to 3.
50 cm).
At least 3 screws could be inserted in all specimens in this area and up to 5 when the fixation area was extended 2 cm proximally.
The mean width of the medial epicondylar area was 2.
19 cm (95% CI, 2.
03 to 2.
33 cm), space enough for the distal fixation of the plate.
The ulnar nerve was at risk only from the tip of the most distal screw (mean distance of 2.
50 mm; 95% CI, 1.
60 to 3.
40 mm) in specimens with a very narrow medial epicondylar area.
Conclusions: This approach provides adequate fixation for distal humeral shaft fractures, but proper clinical studies must be undertaken.
Clinical Relevance: This new approach avoids the risk of radial nerve injury.

Related Results

Arthroscopy-assisted reduction for Jacob type II pediatric humeral lateral condyle fractures: a clinical efficacy study
Arthroscopy-assisted reduction for Jacob type II pediatric humeral lateral condyle fractures: a clinical efficacy study
Background Minimally invasive approaches are being increasingly employed in pediatric orthopedic trauma surgery. Clinical practice has seen applications of mini...
Periprosthetic Humeral Fractures in Shoulder Arthroplasty
Periprosthetic Humeral Fractures in Shoulder Arthroplasty
» The reported combined rates of intraoperative and postoperative periprosthetic humeral fractures range widely, from 1.2% to 19.4%.» The risk factors for an intraoperative humeral...
Asymptomatic Osteonecrosis of the Trochlea in an Adolescent: A Case Report
Asymptomatic Osteonecrosis of the Trochlea in an Adolescent: A Case Report
Abstract Introduction Osteonecrosis, also known as avascular necrosis, aseptic necrosis, or ischemic necrosis, results from a temporary or permanent halt in blood flow to a portion...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Outcome of Humeral Shaft Fracture Treated with Anteromedial Plating through an Anterolateral Approach
Outcome of Humeral Shaft Fracture Treated with Anteromedial Plating through an Anterolateral Approach
Introduction: Humerus shaft fracture is a common injury representing 1.2-3% of all fractures. It can be managed both conservatively and operatively with various modalities. Among o...
Strategies of Osteosynthesis: Problems and Perspectives
Strategies of Osteosynthesis: Problems and Perspectives
Background. Urgent osteosynthesis requires number of organizational, material, technical and staff resources. Aim of the study to determine advantages and disadvantages of existi...
Fractures of the Diaphysis of the Humerus. Our Therapeutic Vision
Fractures of the Diaphysis of the Humerus. Our Therapeutic Vision
Introduction: Fractures of the humeral shaft are relatively common, accounting for approximately 1% to 5% of all fractures. The annual incidence ranges between 13 and 20 per 100,00...
Effect of Normalizing on Semi Float Axle Shaft Performance - Case Study
Effect of Normalizing on Semi Float Axle Shaft Performance - Case Study
The primary function of axle shaft in semi float rear axle is to transmit the power to wheels. These shafts would experience the torsional load along with bending load as well. Hen...

Back to Top