Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Examination of the Effect of Switching Dialysis Membranes on the Immune Response to Influenza Virus Vaccination in Hemodialysis Patients

View through CrossRef
Introduction: In this study, we examined the effect of switching dialysis membranes on the response to influenza virus vaccination in HD patients. Methods: This study consisted of two phases. In phase 1, antibody titers were measured and compared between HD patients and healthy volunteers (HVs) before and after vaccination against influenza virus. Using antibody titers 4 weeks after vaccination, HD patients and HVs were classified according to seroconversion (i.e., antibody titers against all four strains were >20-fold) or non-seroconversion (i.e., antibody titer against at least one strain was <20-fold). In the phase 2, we examined whether the change in the dialysis membrane from a polysulfone (PS) to a polymethyl methacrylate (PMMA) membrane affected the response to vaccination in HD patients without seroconversion in response to the vaccine the previous year. Patients with seroconversion and non-seroconversion were classified as responders and nonresponders, respectively. Additionally, we compared clinical data. Results: In the phase 1, 110 HD patients and 80 HVs were enrolled, and their seroconversion rates were 58.6% and 72.5%, respectively. In the phase 2, 20 HD patients without seroconversion in response to the vaccine the previous year were enrolled, and the dialyzer membrane was changed to PMMA 5 months before annual vaccination. After annual vaccination, 5 and 15 HD patients were categorized as responders and nonresponders, respectively. In the responders, β2-microglobulin, white blood cell counts, platelet counts, and serum albumin levels (Alb) were all higher than in the nonresponders. Conclusion: The responsiveness to vaccination against influenza virus was lower in HD patients compared with HVs. Changing the dialysis membrane from PS to PMMA appeared to affect the response to vaccination in HD patients.
Title: Examination of the Effect of Switching Dialysis Membranes on the Immune Response to Influenza Virus Vaccination in Hemodialysis Patients
Description:
Introduction: In this study, we examined the effect of switching dialysis membranes on the response to influenza virus vaccination in HD patients.
Methods: This study consisted of two phases.
In phase 1, antibody titers were measured and compared between HD patients and healthy volunteers (HVs) before and after vaccination against influenza virus.
Using antibody titers 4 weeks after vaccination, HD patients and HVs were classified according to seroconversion (i.
e.
, antibody titers against all four strains were >20-fold) or non-seroconversion (i.
e.
, antibody titer against at least one strain was <20-fold).
In the phase 2, we examined whether the change in the dialysis membrane from a polysulfone (PS) to a polymethyl methacrylate (PMMA) membrane affected the response to vaccination in HD patients without seroconversion in response to the vaccine the previous year.
Patients with seroconversion and non-seroconversion were classified as responders and nonresponders, respectively.
Additionally, we compared clinical data.
Results: In the phase 1, 110 HD patients and 80 HVs were enrolled, and their seroconversion rates were 58.
6% and 72.
5%, respectively.
In the phase 2, 20 HD patients without seroconversion in response to the vaccine the previous year were enrolled, and the dialyzer membrane was changed to PMMA 5 months before annual vaccination.
After annual vaccination, 5 and 15 HD patients were categorized as responders and nonresponders, respectively.
In the responders, β2-microglobulin, white blood cell counts, platelet counts, and serum albumin levels (Alb) were all higher than in the nonresponders.
Conclusion: The responsiveness to vaccination against influenza virus was lower in HD patients compared with HVs.
Changing the dialysis membrane from PS to PMMA appeared to affect the response to vaccination in HD patients.

Related Results

Assessment of implementation of the Pradhan Mantri national dialysis Programme in Hospitals in Delhi
Assessment of implementation of the Pradhan Mantri national dialysis Programme in Hospitals in Delhi
Background: Annual-demand for haemodialysis-sessions in India is 3.4 Crores. To make Renal-care-services affordable to APL and free to BPL, Ministry of Health and Family Welfare la...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
U.S. utilization patterns of influenza antiviral medications during the 2009 H1N1 influenza pandemic
U.S. utilization patterns of influenza antiviral medications during the 2009 H1N1 influenza pandemic
Please cite this paper as: Borders‐Hemphill and Mosholder (2012) U.S. utilization patterns of influenza antiviral medications during the 2009 H1N1 influenza pandemic. Influenza and...
The Impact of IL28B Gene Polymorphisms on Drug Responses
The Impact of IL28B Gene Polymorphisms on Drug Responses
To achieve high therapeutic efficacy in the patient, information on pharmacokinetics, pharmacodynamics, and pharmacogenetics is required. With the development of science and techno...
Is COVID-19 that different in hemodialysis patients?: A single-center experience
Is COVID-19 that different in hemodialysis patients?: A single-center experience
Coronavirus disease 2019 (COVID-19) has affected millions worldwide, and in particular the care of patients on maintenance hemodialysis. These patients are thought to be at high ri...

Back to Top