Javascript must be enabled to continue!
Optimal operation of paralleled power transformers
View through CrossRef
Parallel operation of power transformers is a common practice. Interest is placed on minimizing the reactive current circulation between transformers due to mismatching of electrical properties. Several control schemes have been applied over the years to ensure efficient operation of paralleled transformers with OLTC. These methods rely either on field measurements of circulating currents or on classic Master/Follower approach and usually assume that the paralleled transformers have matching impedances and OLTC positions. On the present work a generalized approach is implemented calculating the circulating current and minimizing losses directly at the System Operation Office and using the distribution system SCADA to control tap position of the paralleled transformers. This permits the determination of optimal tap matching between transformers and calculation of losses under emergency situations where coupling of transformers with slight impedance mismatch might be considered. In the proposed method a map of circulating current is calculated based on the transformer impedance, X/R ratio and OLTC positions, then the optimal tap positions (minimizing losses) under parallel operation are determined.
Title: Optimal operation of paralleled power transformers
Description:
Parallel operation of power transformers is a common practice.
Interest is placed on minimizing the reactive current circulation between transformers due to mismatching of electrical properties.
Several control schemes have been applied over the years to ensure efficient operation of paralleled transformers with OLTC.
These methods rely either on field measurements of circulating currents or on classic Master/Follower approach and usually assume that the paralleled transformers have matching impedances and OLTC positions.
On the present work a generalized approach is implemented calculating the circulating current and minimizing losses directly at the System Operation Office and using the distribution system SCADA to control tap position of the paralleled transformers.
This permits the determination of optimal tap matching between transformers and calculation of losses under emergency situations where coupling of transformers with slight impedance mismatch might be considered.
In the proposed method a map of circulating current is calculated based on the transformer impedance, X/R ratio and OLTC positions, then the optimal tap positions (minimizing losses) under parallel operation are determined.
Related Results
On the Remote Calibration of Instrumentation Transformers: Influence of Temperature
On the Remote Calibration of Instrumentation Transformers: Influence of Temperature
The remote calibration of instrumentation transformers is theoretically possible using synchronous measurements across a transmission line with a known impedance and a local set of...
[RETRACTED] Optimal Max Keto - Does It ReallyWork? v1
[RETRACTED] Optimal Max Keto - Does It ReallyWork? v1
[RETRACTED]Shedding the unwanted weight and controlling the calories of your body is the most challenging and complicated process. As we start aging, we have to deal with lots of...
Increased Transformer Availability and Reliability
Increased Transformer Availability and Reliability
Abstract
Transformers are important components of the High Voltage electrical grid and electrical power installation in industrial plants such as the petroleum indus...
Resource-saving protections of power transformers against internal faults
Resource-saving protections of power transformers against internal faults
The paper presents the principle of operation of the developed gas protection and oil level control, the purpose of which is to protect power transformers from short circuits. The ...
[RETRACTED] Keto Max Power - BURN FATINSTEAD OF CARBS with Keto Max Power! v1
[RETRACTED] Keto Max Power - BURN FATINSTEAD OF CARBS with Keto Max Power! v1
[RETRACTED]Keto Max Power Reviews: Warning! Don’t Buy Dragons Den Pills Fast Until You Read This UK Latest Report Weight gain’s principle of “energy intake exceeding energy spent”...
Analysis of the Performance of Distribution Transformers under Short Circuit Conditions. Experiments
Analysis of the Performance of Distribution Transformers under Short Circuit Conditions. Experiments
The design of power transformers is heavily influenced by their performance during short circuit. This paper explores the experimental analysis of a power transformer with circular...
An express assessment of the technical condition of an oil-filled power transformer using a simulation model based on the vibroacoustic parameters of the transformer tank
An express assessment of the technical condition of an oil-filled power transformer using a simulation model based on the vibroacoustic parameters of the transformer tank
Oil power transformers are the main device that ensures the reliability of power distribution in the electric power network. It is the only device for connecting electric power rin...
Stability of anterior segments in patients with moderate and high myopia one year after SMILE
Stability of anterior segments in patients with moderate and high myopia one year after SMILE
Abstract
Background: SMILE is one of the most leading-edge corneal refractive surgery.In our study, we aim to investigate the stability of anterior segments in patients wit...

