Javascript must be enabled to continue!
Hybrid Heat Pump Performance Evaluation in Different Operation Modes for Single-Family House
View through CrossRef
Hybrid heat pump (HHP) represents a heating system (HS) that simultaneously utilises two or more energy sources. The key novelty is the integration of an optimised control strategy, effectively maximising the efficiency of both the heat pump and gas boiler segments. In this study, a HHP system that consists of an air-source heat pump (ASHP) and a condensing-type gas boiler (GB) for a two-story single-family house was calculated and validated. The results from three different calculation methods were obtained: the heat pump manufacturer’s calculator, the simulator programme, and the calculations based on real measured data. Two operation modes were tested: economic mode, where the cheapest energy resource becomes the priority, and ecological mode, where the system operates using the energy resource with lowest CO2 emissions. When comparing consumed energy, there was a 15.36% variance between the manufacturer’s program and the actual measured data, while for produced energy, the difference amounted to 25.81%. It was found that the balance point temperature is −7 °C, where the heat pump unit of the HHP system can cover necessary heat losses until that point, while the gas boiler operates at lower temperatures. Changes in electricity price can significantly influence the point of the system switch, but the possibility to cover heat loads of the heat pump unit always has to be taken into account.
Title: Hybrid Heat Pump Performance Evaluation in Different Operation Modes for Single-Family House
Description:
Hybrid heat pump (HHP) represents a heating system (HS) that simultaneously utilises two or more energy sources.
The key novelty is the integration of an optimised control strategy, effectively maximising the efficiency of both the heat pump and gas boiler segments.
In this study, a HHP system that consists of an air-source heat pump (ASHP) and a condensing-type gas boiler (GB) for a two-story single-family house was calculated and validated.
The results from three different calculation methods were obtained: the heat pump manufacturer’s calculator, the simulator programme, and the calculations based on real measured data.
Two operation modes were tested: economic mode, where the cheapest energy resource becomes the priority, and ecological mode, where the system operates using the energy resource with lowest CO2 emissions.
When comparing consumed energy, there was a 15.
36% variance between the manufacturer’s program and the actual measured data, while for produced energy, the difference amounted to 25.
81%.
It was found that the balance point temperature is −7 °C, where the heat pump unit of the HHP system can cover necessary heat losses until that point, while the gas boiler operates at lower temperatures.
Changes in electricity price can significantly influence the point of the system switch, but the possibility to cover heat loads of the heat pump unit always has to be taken into account.
Related Results
Increased life expectancy of heart failure patients in a rural center by a multidisciplinary program
Increased life expectancy of heart failure patients in a rural center by a multidisciplinary program
Abstract
Funding Acknowledgements
Type of funding sources: None.
INTRODUCTION Patients with heart failure (HF)...
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
<p><em><span style="font-size: 11.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-langua...
Primary PCI: a reasonable treatment for STEMI care during the COVID-19 pandemic
Primary PCI: a reasonable treatment for STEMI care during the COVID-19 pandemic
Abstract
Funding Acknowledgements
Type of funding sources: None.
Introduction
...
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
<span style="font-size:11pt"><span style="background:#f9f9f4"><span style="line-height:normal"><span style="font-family:Calibri,sans-serif"><b><spa...
Family Pediatrics
Family Pediatrics
ABSTRACT/EXECUTIVE SUMMARYWhy a Task Force on the Family?The practice of pediatrics is unique among medical specialties in many ways, among which is the nearly certain presence of ...
Optimisation of Heating System Powered by Air Heat Pump and Gas Condensing Boiler Hybrid Unit
Optimisation of Heating System Powered by Air Heat Pump and Gas Condensing Boiler Hybrid Unit
Gas condensing boiler and air to water heat pump hybrid unit is an optimal way to introduce renewable energy resources in existing buildings. Two energy sources (gas & electric...
IMPLEMENTATION OF A HYBRID INTERMITTENT HEAT SUPPLY SYSTEM FOR EDUCATIONAL INSTITUTIONS
IMPLEMENTATION OF A HYBRID INTERMITTENT HEAT SUPPLY SYSTEM FOR EDUCATIONAL INSTITUTIONS
The experience of introducing a hybrid intermittent heating system for educational institutions is presented. The analysis of theoretical and experimental research, modern energy t...
Investigation of vortex in pump sump by V3V measurements
Investigation of vortex in pump sump by V3V measurements
Abstract
The aims, scope and conclusions of the paper must be in a self-contained abstract of a single paragraph with 60-120 words. The abstract must be informative ...

