Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Influence of plasmon excitations on atomic-resolution quantitative 4D scanning transmission electron microscopy

View through CrossRef
AbstractScanning transmission electron microscopy (STEM) allows to gain quantitative information on the atomic-scale structure and composition of materials, satisfying one of todays major needs in the development of novel nanoscale devices. The aim of this study is to quantify the impact of inelastic, i.e. plasmon excitations (PE), on the angular dependence of STEM intensities and answer the question whether these excitations are responsible for a drastic mismatch between experiments and contemporary image simulations observed at scattering angles below $$\sim $$ ∼ 40 mrad. For the two materials silicon and platinum, the angular dependencies of elastic and inelastic scattering are investigated. We utilize energy filtering in two complementary microscopes, which are representative for the systems used for quantitative STEM, to form position-averaged diffraction patterns as well as atomically resolved 4D STEM data sets for different energy ranges. The resulting five-dimensional data are used to elucidate the distinct features in real and momentum space for different energy losses. We find different angular distributions for the elastic and inelastic scattering, resulting in an increased low-angle intensity ($$\sim $$ ∼ 10–40 mrad). The ratio of inelastic/elastic scattering increases with rising sample thickness, while the general shape of the angular dependency is maintained. Moreover, the ratio increases with the distance to an atomic column in the low-angle regime. Since PE are usually neglected in image simulations, consequently the experimental intensity is underestimated at these angles, which especially affects bright field or low-angle annular dark field imaging. The high-angle regime, however, is unaffected. In addition, we find negligible impact of inelastic scattering on first-moment imaging in momentum-resolved STEM, which is important for STEM techniques to measure internal electric fields in functional nanostructures. To resolve the discrepancies between experiment and simulation, we present an adopted simulation scheme including PE. This study highlights the necessity to take into account PE to achieve quantitative agreement between simulation and experiment. Besides solving the fundamental question of missing physics in established simulations, this finally allows for the quantitative evaluation of low-angle scattering, which contains valuable information about the material investigated.
Title: Influence of plasmon excitations on atomic-resolution quantitative 4D scanning transmission electron microscopy
Description:
AbstractScanning transmission electron microscopy (STEM) allows to gain quantitative information on the atomic-scale structure and composition of materials, satisfying one of todays major needs in the development of novel nanoscale devices.
The aim of this study is to quantify the impact of inelastic, i.
e.
plasmon excitations (PE), on the angular dependence of STEM intensities and answer the question whether these excitations are responsible for a drastic mismatch between experiments and contemporary image simulations observed at scattering angles below $$\sim $$ ∼ 40 mrad.
For the two materials silicon and platinum, the angular dependencies of elastic and inelastic scattering are investigated.
We utilize energy filtering in two complementary microscopes, which are representative for the systems used for quantitative STEM, to form position-averaged diffraction patterns as well as atomically resolved 4D STEM data sets for different energy ranges.
The resulting five-dimensional data are used to elucidate the distinct features in real and momentum space for different energy losses.
We find different angular distributions for the elastic and inelastic scattering, resulting in an increased low-angle intensity ($$\sim $$ ∼ 10–40 mrad).
The ratio of inelastic/elastic scattering increases with rising sample thickness, while the general shape of the angular dependency is maintained.
Moreover, the ratio increases with the distance to an atomic column in the low-angle regime.
Since PE are usually neglected in image simulations, consequently the experimental intensity is underestimated at these angles, which especially affects bright field or low-angle annular dark field imaging.
The high-angle regime, however, is unaffected.
In addition, we find negligible impact of inelastic scattering on first-moment imaging in momentum-resolved STEM, which is important for STEM techniques to measure internal electric fields in functional nanostructures.
To resolve the discrepancies between experiment and simulation, we present an adopted simulation scheme including PE.
This study highlights the necessity to take into account PE to achieve quantitative agreement between simulation and experiment.
Besides solving the fundamental question of missing physics in established simulations, this finally allows for the quantitative evaluation of low-angle scattering, which contains valuable information about the material investigated.

Related Results

Atomic electron tomography: 3D structures without crystals
Atomic electron tomography: 3D structures without crystals
BACKGROUND To understand material properties and functionality at the most fundamental level, one must know the three-dimensional (3D) positions of atoms with high prec...
Tailoring plasmons in van der Waals nano-materials by design
Tailoring plasmons in van der Waals nano-materials by design
Plasmonics in two-dimensional (2D) materials and their van der Waals (vdW) heterostructures, as a key component of modern nanophotonics, have significant advancements with the adve...
Nanophotonics with charged particles
Nanophotonics with charged particles
(English) Among the fundamental constituents of matter, charged particles such electrons and positrons are leading protagonists in physical phenomena associated with small (~ meV) ...
Atomic‐Scale Compositional Fluctuations in Ternary III‐Nitride Nanowires
Atomic‐Scale Compositional Fluctuations in Ternary III‐Nitride Nanowires
Ternary InGaN and AlGaN alloys have been sought after for the application of various optoelectronic devices spanning a large spectral range between the deep ultraviolet (DUV) and i...
Enhanced scanning control in a confocal scanning laser microscope
Enhanced scanning control in a confocal scanning laser microscope
AbstractA fast and flexible scanning unit, allowing scanning rates of more than 1 kHz over regions identified in a specimen, has been developed and evaluated. This scanning unit re...
Enhanced scanning control in a confocal scanning laser microscope
Enhanced scanning control in a confocal scanning laser microscope
AbstractA fast and flexible scanning unit, allowing scanning rates of more than 1 kHz over regions identified in a specimen, has been developed and evaluated. This scanning unit re...
H atom parameters: how Classical Physics gives new/clear results
H atom parameters: how Classical Physics gives new/clear results
In our recent paper [A. Bacchieri, Phys. Essays 36, 61 (2023)], we had found that the total escape speed from all the masses in the universe, u = (‐2 u)1/2, where u is the total gr...

Back to Top