Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Endoscopic ultrasound-guided gastroenterostomy using large-diameter (20 mm) lumen apposing metal stent (LLAMS)

View through CrossRef
Abstract Background and study aims Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) using a 15-mm lumen apposing metal stent (LAMS) has emerged as a viable alternative to surgical gastrojejunostomy for management of gastric outlet obstruction (GOO). However, given the size of the anastomosis created with a 15-mm LAMS, long-term luminal patency and clinical outcomes may be suboptimal. The aim of this study was to evaluate the technical feasibility, efficacy, and safety of EUS-GE with a large-diameter (20 mm) LAMS (LLAMS). Patients and methods A retrospective analysis of a prospectively maintained database of all patients undergoing EUS-GE with LLAMS between December 1, 2018 and September 30, 2020 was performed. All EUS-GEs were performed using a cautery-enhanced LLAMS. Results Thirty-three patients were referred for endoscopic management of GOO. Two patients were excluded due to a lack of an adequate window for EUS-GE. The remaining 31 patients (93.94 %) (mean age: 61.35 ± 16.52 years; 54.84 % males) underwent EUS-GE using LLAMS for malignant (n = 23) and benign (n = 8) GOO. Technical success was achieved in all patients (100 %) with attempted EUS-GE. Complete clinical success (tolerance of regular diet) was achieved in 93.55 % of patients (n = 29). Two patients (6.45 %) had partial clinical success and died of unrelated causes prior to advancing diet beyond full liquids. Overall mean follow-up was 140.84 ± 160.41 days (median 70, range 4–590). All stents remained patent with no evidence of recurrent GOO symptoms. One patient (3.23 %) developed an asymptomatic clean-based jejunal ulcer on 3-month follow-up endoscopy. Conclusions EUS-GE with LLAMS is a technically feasible, effective and safe option for patients with GOO allowing for tolerability of regular diet. Future prospective, ideally randomized studies comparing long-term outcomes of EUS-GE with 20- and 15-mm LAMS are required.
Title: Endoscopic ultrasound-guided gastroenterostomy using large-diameter (20 mm) lumen apposing metal stent (LLAMS)
Description:
Abstract Background and study aims Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) using a 15-mm lumen apposing metal stent (LAMS) has emerged as a viable alternative to surgical gastrojejunostomy for management of gastric outlet obstruction (GOO).
However, given the size of the anastomosis created with a 15-mm LAMS, long-term luminal patency and clinical outcomes may be suboptimal.
The aim of this study was to evaluate the technical feasibility, efficacy, and safety of EUS-GE with a large-diameter (20 mm) LAMS (LLAMS).
Patients and methods A retrospective analysis of a prospectively maintained database of all patients undergoing EUS-GE with LLAMS between December 1, 2018 and September 30, 2020 was performed.
All EUS-GEs were performed using a cautery-enhanced LLAMS.
Results Thirty-three patients were referred for endoscopic management of GOO.
Two patients were excluded due to a lack of an adequate window for EUS-GE.
The remaining 31 patients (93.
94 %) (mean age: 61.
35 ± 16.
52 years; 54.
84 % males) underwent EUS-GE using LLAMS for malignant (n = 23) and benign (n = 8) GOO.
Technical success was achieved in all patients (100 %) with attempted EUS-GE.
Complete clinical success (tolerance of regular diet) was achieved in 93.
55 % of patients (n = 29).
Two patients (6.
45 %) had partial clinical success and died of unrelated causes prior to advancing diet beyond full liquids.
Overall mean follow-up was 140.
84 ± 160.
41 days (median 70, range 4–590).
All stents remained patent with no evidence of recurrent GOO symptoms.
One patient (3.
23 %) developed an asymptomatic clean-based jejunal ulcer on 3-month follow-up endoscopy.
Conclusions EUS-GE with LLAMS is a technically feasible, effective and safe option for patients with GOO allowing for tolerability of regular diet.
Future prospective, ideally randomized studies comparing long-term outcomes of EUS-GE with 20- and 15-mm LAMS are required.

Related Results

Novel functionalized and patterned surfaces for cardiovascular applications
Novel functionalized and patterned surfaces for cardiovascular applications
Nowadays, cardiovascular diseases are mainly treated by implantation of a metallic or polymeric mesh, called stent, which maintains the artery widely open. This technique shows ver...
A233 CANADIAN EXPERIENCE OF ENDOSCOPIC ULTRASOUND-GUIDED GALLBLADDER DRAINAGE: A CASE SERIES
A233 CANADIAN EXPERIENCE OF ENDOSCOPIC ULTRASOUND-GUIDED GALLBLADDER DRAINAGE: A CASE SERIES
Abstract Background Endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) is an emerging treatment for acute cholecystitis...
Clinical study of biodegradable polymer stent versus durable polymer stent in treating long coronary lesions
Clinical study of biodegradable polymer stent versus durable polymer stent in treating long coronary lesions
Objective This study compared the clinical efficacy and safety of homemade biodegradable polymer rapamycin-eluting stent (EXCEL TM) and durable polymer rapamycin-...
e0533 The effect of QCA in left main lesion
e0533 The effect of QCA in left main lesion
Objective Using Intravascular ultrasound (IVUS) as a standard to evaluate the ability of Quantitative Coronary Angiography (QCA) in judging the lumen diameter bef...

Back to Top