Repeated intraocular lens dislocation followed by haptic deformation and loss of tension: a case report
View through CrossRef
Abstract
Background: Intraocular lens (IOL) dislocation is a rare but serious postoperative complication of intraocular lens implantation, so far, there is no report describing late intraocular lens dislocation caused by a deformed haptic piercing through the iris. Case report: A 29-year-old male developed IOL dislocation one and a half years after IOL implantation in his right eye. The eye examination showed that haptic pierced the iris at 10 o'clock in his right eye, according to intraoperative exploration, the haptic was deformed and became less elastic, the patient underwent the surgery of IOL reposition for various factors, but finally did not achieve a satisfactory outcome. Conclusion: Late IOL dislocation followed by haptic deformation is difficult to detect unless there are serious complications. When the position of IOL haptics is not in a plane with its optical surface, it should be highly vigilant that the function of the haptics may be abnormal. IOL replacement should be performed as soon as possible for the IOL dislocation caused by the loss of haptic tension.
Springer Science and Business Media LLC
Title: Repeated intraocular lens dislocation followed by haptic deformation and loss of tension: a case report
Description:
Abstract
Background: Intraocular lens (IOL) dislocation is a rare but serious postoperative complication of intraocular lens implantation, so far, there is no report describing late intraocular lens dislocation caused by a deformed haptic piercing through the iris.
Case report: A 29-year-old male developed IOL dislocation one and a half years after IOL implantation in his right eye.
The eye examination showed that haptic pierced the iris at 10 o'clock in his right eye, according to intraoperative exploration, the haptic was deformed and became less elastic, the patient underwent the surgery of IOL reposition for various factors, but finally did not achieve a satisfactory outcome.
Conclusion: Late IOL dislocation followed by haptic deformation is difficult to detect unless there are serious complications.
When the position of IOL haptics is not in a plane with its optical surface, it should be highly vigilant that the function of the haptics may be abnormal.
IOL replacement should be performed as soon as possible for the IOL dislocation caused by the loss of haptic tension.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
SIMPLE REFIXATION OF A DISLOCATED HAPTIC OF FLANGED INTRAOCULAR LENS USING A 25-GAUGE NEEDLE
SIMPLE REFIXATION OF A DISLOCATED HAPTIC OF FLANGED INTRAOCULAR LENS USING A 25-GAUGE NEEDLE
Purpose:
To report the development of a novel, simple-to-use technique for the salvage of a haptic of dislocated flanged intraocular lens during a retinal detachment su...
Chest Wall Hydatid Cysts: A Systematic Review
Chest Wall Hydatid Cysts: A Systematic Review
Abstract
Introduction
Given the rarity of chest wall hydatid disease, information on this condition is primarily drawn from case reports. Hence, this study systematically reviews t...
The Effects of Different Shapes of Capsulorrhexis on Postoperative Refractive Outcomes and Effective Position of the Intraocular Lens in Cataract Surgery
The Effects of Different Shapes of Capsulorrhexis on Postoperative Refractive Outcomes and Effective Position of the Intraocular Lens in Cataract Surgery
Abstract
Background:To evaluate the effects of anterior capsular opening size on deviation from predicted refraction and the effective position of the intraocular lens (ELP...
Key Surgical Steps for 4-Haptic Delivery Into the Posterior Chamber During Implantable Collamer Lens Surgery
Key Surgical Steps for 4-Haptic Delivery Into the Posterior Chamber During Implantable Collamer Lens Surgery
Purpose:
To introduce the key surgical steps of 4-haptic placement in the posterior chamber during Implantable Collamer Lens (ICL) implantation and evaluate the...
Guiding Breathing at the Resonance Frequency with Haptic Sensors Potentiates Cardiac Coherence
Guiding Breathing at the Resonance Frequency with Haptic Sensors Potentiates Cardiac Coherence
Cardiac coherence is a state achieved when one controls their breathing rate during the so-called resonance frequency breathing. This maneuver allows respiratory-driven vagal modul...
Dynamic Structural Evolution of Nanocrystalline Aluminum During Ratcheting Deformation
Dynamic Structural Evolution of Nanocrystalline Aluminum During Ratcheting Deformation
The ratcheting deformation mechanism and dislocation behavior at the grain boundary (GB) of nanocrystalline (NC) aluminum (Al) with a grain size of ∼8 nm are investigated by molecu...