Javascript must be enabled to continue!
Interobserver Agreement in Automatic Segmentation Annotation of Prostate Magnetic Resonance Imaging
View through CrossRef
We aimed to compare the performance and interobserver agreement of radiologists manually segmenting images or those assisted by automatic segmentation. We further aimed to reduce interobserver variability and improve the consistency of radiomics features. This retrospective study included 327 patients diagnosed with prostate cancer from September 2016 to June 2018; images from 228 patients were used for automatic segmentation construction, and images from the remaining 99 were used for testing. First, four radiologists with varying experience levels retrospectively segmented 99 axial prostate images manually using T2-weighted fat-suppressed magnetic resonance imaging. Automatic segmentation was performed after 2 weeks. The Pyradiomics software package v3.1.0 was used to extract the texture features. The Dice coefficient and intraclass correlation coefficient (ICC) were used to evaluate segmentation performance and the interobserver consistency of prostate radiomics. The Wilcoxon rank sum test was used to compare the paired samples, with the significance level set at p < 0.05. The Dice coefficient was used to accurately measure the spatial overlap of manually delineated images. In all the 99 prostate segmentation result columns, the manual and automatic segmentation results of the senior group were significantly better than those of the junior group (p < 0.05). Automatic segmentation was more consistent than manual segmentation (p < 0.05), and the average ICC reached >0.85. The automatic segmentation annotation performance of junior radiologists was similar to that of senior radiologists performing manual segmentation. The ICC of radiomics features increased to excellent consistency (0.925 [0.888~0.950]). Automatic segmentation annotation provided better results than manual segmentation by radiologists. Our findings indicate that automatic segmentation annotation helps reduce variability in the perception and interpretation between radiologists with different experience levels and ensures the stability of radiomics features.
Title: Interobserver Agreement in Automatic Segmentation Annotation of Prostate Magnetic Resonance Imaging
Description:
We aimed to compare the performance and interobserver agreement of radiologists manually segmenting images or those assisted by automatic segmentation.
We further aimed to reduce interobserver variability and improve the consistency of radiomics features.
This retrospective study included 327 patients diagnosed with prostate cancer from September 2016 to June 2018; images from 228 patients were used for automatic segmentation construction, and images from the remaining 99 were used for testing.
First, four radiologists with varying experience levels retrospectively segmented 99 axial prostate images manually using T2-weighted fat-suppressed magnetic resonance imaging.
Automatic segmentation was performed after 2 weeks.
The Pyradiomics software package v3.
1.
0 was used to extract the texture features.
The Dice coefficient and intraclass correlation coefficient (ICC) were used to evaluate segmentation performance and the interobserver consistency of prostate radiomics.
The Wilcoxon rank sum test was used to compare the paired samples, with the significance level set at p < 0.
05.
The Dice coefficient was used to accurately measure the spatial overlap of manually delineated images.
In all the 99 prostate segmentation result columns, the manual and automatic segmentation results of the senior group were significantly better than those of the junior group (p < 0.
05).
Automatic segmentation was more consistent than manual segmentation (p < 0.
05), and the average ICC reached >0.
85.
The automatic segmentation annotation performance of junior radiologists was similar to that of senior radiologists performing manual segmentation.
The ICC of radiomics features increased to excellent consistency (0.
925 [0.
888~0.
950]).
Automatic segmentation annotation provided better results than manual segmentation by radiologists.
Our findings indicate that automatic segmentation annotation helps reduce variability in the perception and interpretation between radiologists with different experience levels and ensures the stability of radiomics features.
Related Results
Exploring Large Language Models Integration in the Histopathologic Diagnosis of Skin Diseases: A Comparative Study
Exploring Large Language Models Integration in the Histopathologic Diagnosis of Skin Diseases: A Comparative Study
Abstract
Introduction
The exact manner in which large language models (LLMs) will be integrated into pathology is not yet fully comprehended. This study examines the accuracy, bene...
Correlation between Prostate-Specific Antigen Levels and Prostate Imaging Reporting and Data System score: A Retrospective Study
Correlation between Prostate-Specific Antigen Levels and Prostate Imaging Reporting and Data System score: A Retrospective Study
Introduction: Prostate cancer is a prevalent and potentially lethal malignancy affecting men worldwide. To enhance early detection and accurate risk stratification, various diagnos...
Evaluation of automatic pericardial segmentation methods in computed tomography images
Evaluation of automatic pericardial segmentation methods in computed tomography images
Abstract
Funding Acknowledgements
Type of funding sources: Public grant(s) – National budget only. Main funding source(s): Funda...
AI‐enabled precise brain tumor segmentation by integrating Refinenet and contour‐constrained features in MRI images
AI‐enabled precise brain tumor segmentation by integrating Refinenet and contour‐constrained features in MRI images
AbstractBackgroundMedical image segmentation is a fundamental task in medical image analysis and has been widely applied in multiple medical fields. The latest transformer‐based de...
Efficacy of Magnetic Resonance Imaging/ Ultrasound-Guided Target Biopsy in Detecting Clinically Significant Prostate Cancer
Efficacy of Magnetic Resonance Imaging/ Ultrasound-Guided Target Biopsy in Detecting Clinically Significant Prostate Cancer
Introduction: Prostate cancer remains a formidable health challenge, demanding diagnostic strategies that balance accuracy and invasiveness. To enhance early detection and accurate...
Analysis of the spatial distribution and clinical features of prostate cancer in transperineal prostate biopsy
Analysis of the spatial distribution and clinical features of prostate cancer in transperineal prostate biopsy
Abstract
Background Recently, most studies on the spatial distribution of the prostate cancer are based on the samples confirmed by transrectal prostate biopsy (TRBx), whic...
Predictive value of prostate calcification for future cancer occurrence: a retrospective long-term follow-up cohort study
Predictive value of prostate calcification for future cancer occurrence: a retrospective long-term follow-up cohort study
Objective: Although prostate calcification is often identified on pelvic CT images, calcification itself is usually not considered clinically significant. A recent histological stu...
Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...

