Javascript must be enabled to continue!
Clinical features and treatment of “Non-dislocated hyperextension tibial plateau fracture”
View through CrossRef
AbstractBackgroundTo explore the epidemiological characteristics, clinical characteristics, treatment strategies, and clinical results of non-dislocated hyperextension tibial plateau fracture.MethodA total of 25 cases of non-dislocated hyperextension tibial plateau fracture patients were collected (12 males and 13 females), aged 27–79 years. Preoperative tibial plateau posterior slope angle was − 10~0° (average − 5.2°). Preoperative MRI showed 5 cases of MCL injury, 3 cases of PLC complex injury, and 2 cases of PLC + PCL injury. The change of tibial plateau posterior slope angle was more than 10° in patients with ligament injury, and the patients with a tibial plateau posterior slope angle change less than 10° had no ligament injury; 6 patients with simple column fracture had a ligament injury, 2 patients with bilateral column fracture had a ligament injury, and 2 patients with three column fracture had a ligament injury.ResultsPatients were followed up for 12–24 months (average 16.4 months). The operative time was 65–180 min (average 124 min), and the blood loss was 20–200 ml (average 106 ml). The plate was placed on the anterior part of tibial plateau. Evaluation of postoperative fracture reduction was as follows: 20 cases reached anatomic reduction, 5 cases reached good reduction (between 2 and 5 mm articular surface collapse), and the excellent rate of fracture reduction was 100%. The fracture healing time was 3–6 months (average 3.3 months). The postoperative knee Rasmussen score was 18–29 (average 24.9), and the postoperative knee joint mobility was 90–130° (average 118°). Two patients suffered superficial infection.ConclusionsThe main imaging characteristic of “non-dislocated hyperextension tibial plateau fracture” is the change of tibial plateau posterior slope angle. The injury of single anteromedial column/anterolateral column fracture is easy to combine with “diagonal” injury, and when the tPSA changes more than 10°, it is easy to be combined with ligament injury. By reducing the joint articular surface and lower limb force line, repairing the soft tissue structure, and reconstructing the knee joint stability, we can get satisfactory results.Trial registrationIt was a retrospective study. This study was consistent with the ethical standards of the Second Affiliated Hospital of Zhejiang University Medical College and was approved by the hospital ethics committee and the trial registration number of our hospital was20180145.
Springer Science and Business Media LLC
Title: Clinical features and treatment of “Non-dislocated hyperextension tibial plateau fracture”
Description:
AbstractBackgroundTo explore the epidemiological characteristics, clinical characteristics, treatment strategies, and clinical results of non-dislocated hyperextension tibial plateau fracture.
MethodA total of 25 cases of non-dislocated hyperextension tibial plateau fracture patients were collected (12 males and 13 females), aged 27–79 years.
Preoperative tibial plateau posterior slope angle was − 10~0° (average − 5.
2°).
Preoperative MRI showed 5 cases of MCL injury, 3 cases of PLC complex injury, and 2 cases of PLC + PCL injury.
The change of tibial plateau posterior slope angle was more than 10° in patients with ligament injury, and the patients with a tibial plateau posterior slope angle change less than 10° had no ligament injury; 6 patients with simple column fracture had a ligament injury, 2 patients with bilateral column fracture had a ligament injury, and 2 patients with three column fracture had a ligament injury.
ResultsPatients were followed up for 12–24 months (average 16.
4 months).
The operative time was 65–180 min (average 124 min), and the blood loss was 20–200 ml (average 106 ml).
The plate was placed on the anterior part of tibial plateau.
Evaluation of postoperative fracture reduction was as follows: 20 cases reached anatomic reduction, 5 cases reached good reduction (between 2 and 5 mm articular surface collapse), and the excellent rate of fracture reduction was 100%.
The fracture healing time was 3–6 months (average 3.
3 months).
The postoperative knee Rasmussen score was 18–29 (average 24.
9), and the postoperative knee joint mobility was 90–130° (average 118°).
Two patients suffered superficial infection.
ConclusionsThe main imaging characteristic of “non-dislocated hyperextension tibial plateau fracture” is the change of tibial plateau posterior slope angle.
The injury of single anteromedial column/anterolateral column fracture is easy to combine with “diagonal” injury, and when the tPSA changes more than 10°, it is easy to be combined with ligament injury.
By reducing the joint articular surface and lower limb force line, repairing the soft tissue structure, and reconstructing the knee joint stability, we can get satisfactory results.
Trial registrationIt was a retrospective study.
This study was consistent with the ethical standards of the Second Affiliated Hospital of Zhejiang University Medical College and was approved by the hospital ethics committee and the trial registration number of our hospital was20180145.
Related Results
Short‐term outcome and complications ofTPLOusing anatomically contoured locking compression plates in small/medium‐breed dogs with “excessive” tibial plateau angle
Short‐term outcome and complications ofTPLOusing anatomically contoured locking compression plates in small/medium‐breed dogs with “excessive” tibial plateau angle
OBJECTIVESTo report short‐term radiographic and clinical outcome and complications following tibial plateau levelling osteotomy for the treatment of cranial cruciate ligament insuf...
A Locking Plate Designed With Cluster of Head Screws Would Be Biomechanically Superior Than Conventional Buttress Plate For The Fixation of Posteromedial Tibial Plateau Fractures: A Computational Assessment
A Locking Plate Designed With Cluster of Head Screws Would Be Biomechanically Superior Than Conventional Buttress Plate For The Fixation of Posteromedial Tibial Plateau Fractures: A Computational Assessment
Abstract
Background: Dealing with high-energy fractures of the tibial plateau remains a challenge despite advances in implants, surgical approaches, and imaging methods. Po...
Fracture Modelling Using Seismic Based Fracture Intensity Volume, a Case Study in Middle East
Fracture Modelling Using Seismic Based Fracture Intensity Volume, a Case Study in Middle East
Abstract
In this paper, a case study in a fractured carbonate reservoir is presented to demonstrate the approach of fracture modeling using fracture intensity vol...
Anthropometric measurements of tibial plateau and correlation with the current tibial implants
Anthropometric measurements of tibial plateau and correlation with the current tibial implants
AbstractPurposeThe aim of the study was to make an anthropometric analysis at the resected surfaces of the proximal tibia in the Turkish population and to compare the data with the...
FRACTURES OF THE TIBIAL COLUMN (FCT), FRACTURES OF THE TIBIAL EMINENCE OR INTERCONDYLAR EMINENCE
FRACTURES OF THE TIBIAL COLUMN (FCT), FRACTURES OF THE TIBIAL EMINENCE OR INTERCONDYLAR EMINENCE
Introduction: Tibial spine fractures (TSCF), also called tibial eminence or intercondylar eminence fractures, are defined as bony or chondral avulsions of the tibial plateau at the...
The Complex and Well-Developed Morphological and Histological Structures of the Gastrointestinal Tract of the Plateau Zokor Improve Its Digestive Adaptability to High-Fiber Foods
The Complex and Well-Developed Morphological and Histological Structures of the Gastrointestinal Tract of the Plateau Zokor Improve Its Digestive Adaptability to High-Fiber Foods
The morphological and histological traits of the gastrointestinal tract (GIT) enable the animal to perform some specific functions that enhance the species’ adaptability to environ...
Surgical factors that contribute to tibial periprosthetic fracture after cementless Oxford Unicompartmental Knee Replacement: a finite element analysis
Surgical factors that contribute to tibial periprosthetic fracture after cementless Oxford Unicompartmental Knee Replacement: a finite element analysis
BackgroundTibial periprosthetic fracture (TPF) is a severe complication of cementless Oxford Unicompartmental Knee Replacement (OUKR) with patient risk factors including small tibi...
Clinical application of the modified posterolateral approach for treating posterior tibial plateau fractures
Clinical application of the modified posterolateral approach for treating posterior tibial plateau fractures
Objective: To investigate the therapeutic efficacy of the modified posterolateral approach on tibial plateau fractures.Methods: Forty-four patients with tibial plateau fractures we...

