Javascript must be enabled to continue!
Electrochemical Flow-ELISA for Rapid and Sensitive Determination of Microcystin-LR Using Automated Sequential Injection System
View through CrossRef
An amperometric immunoanalysis system based on monoclonal antibodies immobilized on Sepharose beads and packed into a micro-immunocolumn was developed for the quantification of microcystin-LR. Microcystin-LR (MCLR) was used as a reference microcystin variant. Inside the immunocolumn, free microcystins and microcystin-horseradish peroxidase (tracer) were sequentially captured by the immobilized antibodies, and the detection was performed electrochemically using Super AquaBlue ELISA substrate 2,2′-azinobis(3-ethylbenzothiazoline-sulfonic acid) (ABTS). The ABTS●+ generated by enzymatic oxidation of ABTS was electrochemically determined at a carbon working electrode by applying a reduction potential set at 0.4 V versus Ag/AgCl reference electrode. The peak current intensity was inversely proportional to the amount of analyte bound to the immunocolumn. The amperometric flow-ELISA system, which was automatically controlled through the CapSenzeTM (Lund, Sweden) computer software, enabled determination of MCLR as low as 0.01 µg/L. The assay time was very short (20 min for one assay cycle). In addition, the electrochemical signals were not significantly affected by possible interferences which could be present in the real samples. Along with the simplicity of automation, this makes the developed method a promising tool for use in water quality assessment.
Title: Electrochemical Flow-ELISA for Rapid and Sensitive Determination of Microcystin-LR Using Automated Sequential Injection System
Description:
An amperometric immunoanalysis system based on monoclonal antibodies immobilized on Sepharose beads and packed into a micro-immunocolumn was developed for the quantification of microcystin-LR.
Microcystin-LR (MCLR) was used as a reference microcystin variant.
Inside the immunocolumn, free microcystins and microcystin-horseradish peroxidase (tracer) were sequentially captured by the immobilized antibodies, and the detection was performed electrochemically using Super AquaBlue ELISA substrate 2,2′-azinobis(3-ethylbenzothiazoline-sulfonic acid) (ABTS).
The ABTS●+ generated by enzymatic oxidation of ABTS was electrochemically determined at a carbon working electrode by applying a reduction potential set at 0.
4 V versus Ag/AgCl reference electrode.
The peak current intensity was inversely proportional to the amount of analyte bound to the immunocolumn.
The amperometric flow-ELISA system, which was automatically controlled through the CapSenzeTM (Lund, Sweden) computer software, enabled determination of MCLR as low as 0.
01 µg/L.
The assay time was very short (20 min for one assay cycle).
In addition, the electrochemical signals were not significantly affected by possible interferences which could be present in the real samples.
Along with the simplicity of automation, this makes the developed method a promising tool for use in water quality assessment.
Related Results
Widespread Distribution and Adaptive Degradation of Microcystin Degrader (mlr-Genotype) in Lake Taihu, China
Widespread Distribution and Adaptive Degradation of Microcystin Degrader (mlr-Genotype) in Lake Taihu, China
Microbial degradation is an important route for removing environmental microcystins (MCs). Here, we investigated the ecological distribution of microcystin degraders (mlr-genotype)...
Overview of Key Zonal Water Injection Technologies in China
Overview of Key Zonal Water Injection Technologies in China
Abstract
Separated layer water injection is the important technology to realize the oilfield long-term high and stable yield. Through continuous researches and te...
Suppression by carotenoids of microtenoids of microcystin‐induced morphological changes in mouse hepatocytes
Suppression by carotenoids of microtenoids of microcystin‐induced morphological changes in mouse hepatocytes
AbstractMicrocystin‐LR is a liver tumor promoter in the okadaic acid class, a group of potent inhibitors of protein phosphatases 1 and 2A. Because of inhibition of protein phosphat...
7
th
International Symposium on Enabling Technologies for Life Sciences (ETP)
7
th
International Symposium on Enabling Technologies for Life Sciences (ETP)
The seventh in the series of ETP Symposia (see
Rapid Communications in Mass Spectrometry
2012,
26
, ...
Control of Water Injection into a Layered Formation
Control of Water Injection into a Layered Formation
Abstract
In previously published work, we have analyzed transient injection of water from a growing vertical hydrofracture into a low-permeability compressible rock ...
Rapid purification of protein phosphatase 2A from mouse brain by microcystin‐affinity chromatography
Rapid purification of protein phosphatase 2A from mouse brain by microcystin‐affinity chromatography
Microcystin LR. which is a monocyclic heptapeptide containing two L‐amino acids, and leucine and arginine, is a new inhibitor of protein phosphatases 1 and 2A. Microcystin LR‐affin...
Awareness about ELISA technique among dental students
Awareness about ELISA technique among dental students
The enzyme-linked immunosorbent assay (ELISA) can be used to recognize proteins, peptides, antibodies as well as hormones. Often known also as an enzyme immunoassay (EIA), ELISA is...
Optimal Injection Parameters for Enhancing Coalbed Methane Recovery: A Simulation Study from the Shizhuang Block, Qinshui Basin, China
Optimal Injection Parameters for Enhancing Coalbed Methane Recovery: A Simulation Study from the Shizhuang Block, Qinshui Basin, China
The injection of N2 into coal reservoir has great potential in improving recovery of coalbed methane (CBM). In this study, a numerical model was established based on the GEM compon...

