Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Lumbar multifidus layers stiffness at L5-S1 level in prone and sitting posture measured by shear wave elastography

View through CrossRef
BACKGROUND: Multifidus is an important lumbar muscle with distinct superficial and deep fibers responsible for torque production and stabilization, respectively. Its mechanical properties change when transitioning from lying to sitting positions, necessitating enhanced stability. It holds crucial clinical relevance to assess these layers separately, especially in the sitting posture, which demands increased neuromuscular control compared to the prone position. OBJECTIVE: To compare lumbar multifidus stiffness in lying versus sitting postures, analyzing both superficial and deep layers. METHODS: Supersonic Shear Imaging captured elastographic images from 26 asymptomatic volunteers in prone and seated positions. RESULTS: Left multifidus shear modulus in lying: 5.98 ± 1.80/7.96 ± 1.59 kPa (deep/superficial) and sitting: 12.58 ± 4.22/16.04 ± 6.65 kPa. Right side lying: 6.08 ± 1.97/7.80 ± 1.76 kPa and sitting: 13.25 ± 4.61/17.95 ± 7.12 kPa. No side differences (lying p= 0.99, sitting p= 0.43). However, significant inter-postural differences occurred. CONCLUSION: Lumbar multifidus exhibits increased stiffness in sitting, both layers affected, with superior stiffness in superficial versus deep fibers. Applying these findings could enhance assessing multifidus stiffness changes, for classifying tension-induced low back pain stages.
Title: Lumbar multifidus layers stiffness at L5-S1 level in prone and sitting posture measured by shear wave elastography
Description:
BACKGROUND: Multifidus is an important lumbar muscle with distinct superficial and deep fibers responsible for torque production and stabilization, respectively.
Its mechanical properties change when transitioning from lying to sitting positions, necessitating enhanced stability.
It holds crucial clinical relevance to assess these layers separately, especially in the sitting posture, which demands increased neuromuscular control compared to the prone position.
OBJECTIVE: To compare lumbar multifidus stiffness in lying versus sitting postures, analyzing both superficial and deep layers.
METHODS: Supersonic Shear Imaging captured elastographic images from 26 asymptomatic volunteers in prone and seated positions.
RESULTS: Left multifidus shear modulus in lying: 5.
98 ± 1.
80/7.
96 ± 1.
59 kPa (deep/superficial) and sitting: 12.
58 ± 4.
22/16.
04 ± 6.
65 kPa.
Right side lying: 6.
08 ± 1.
97/7.
80 ± 1.
76 kPa and sitting: 13.
25 ± 4.
61/17.
95 ± 7.
12 kPa.
No side differences (lying p= 0.
99, sitting p= 0.
43).
However, significant inter-postural differences occurred.
CONCLUSION: Lumbar multifidus exhibits increased stiffness in sitting, both layers affected, with superior stiffness in superficial versus deep fibers.
Applying these findings could enhance assessing multifidus stiffness changes, for classifying tension-induced low back pain stages.

Related Results

Physical Principles of Elastography: A Primer for Radiologists
Physical Principles of Elastography: A Primer for Radiologists
AbstractElastography is the noninvasive method of qualitative and quantitative evaluation of strain and elastic modulus distribution in soft tissues. In simpler terms, elastography...
Targeted multifidus muscle activation reduces fibrosis of multifidus muscle following intervertebral disc injury
Targeted multifidus muscle activation reduces fibrosis of multifidus muscle following intervertebral disc injury
Abstract Purpose Aerobic exercise produces beneficial outcomes in patients with low back pain and partially attenuates the fibrotic changes to the m...
The Use of Ultrasound-Based Elastography Techniques in Liver Fibrosis: A Narrative Review
The Use of Ultrasound-Based Elastography Techniques in Liver Fibrosis: A Narrative Review
Liver fibrosis staging plays a key role in the prognosis and management of chronic liver disease. Liver biopsy remains the reference standard for fibrosis assessment but is limited...
The Use of Ultrasound-Based Elastography Techniques in Liver Fibrosis: A Narrative Review
The Use of Ultrasound-Based Elastography Techniques in Liver Fibrosis: A Narrative Review
Background: Liver fibrosis staging plays a key role in the prognosis and management of chronic liver disease. Liver biopsy remains the reference standard for fibrosis assessment bu...
Non-invasive endometrial assessment: shear wave elastography in diagnosing endometrial hyperplasia
Non-invasive endometrial assessment: shear wave elastography in diagnosing endometrial hyperplasia
SUMMARY OBJECTIVE: Endometrial hyperplasia is a precursor lesion that may progress to endometrial carcinoma, particularly in cases with atypia. Early and accurate diagnosis is ess...
Test-Retest Reliability of Ultrasound Imaging of Lumbar Multifidus Muscle
Test-Retest Reliability of Ultrasound Imaging of Lumbar Multifidus Muscle
Background to the study: Muscle strength and muscle size measurement are useful indicator of musculoskeletal pathology but it seems difficult at the moment to isolate individual pa...
DIAGNOSTIC ACCURACY OF ULTRASOUND ELASTOGRAPHY IN FOCAL BREAST LESIONS KEEPING HISTOPATHOLOGY AS GOLD STANDARD: A CROSS-SECTIONAL STUDY
DIAGNOSTIC ACCURACY OF ULTRASOUND ELASTOGRAPHY IN FOCAL BREAST LESIONS KEEPING HISTOPATHOLOGY AS GOLD STANDARD: A CROSS-SECTIONAL STUDY
Background: Breast cancer frequently presents as a focal breast lesion, and accurate non-invasive characterization remains essential to guide clinical decision-making and avoid unn...
O9-5 Workplace sitting associated with self-rated perceived global health
O9-5 Workplace sitting associated with self-rated perceived global health
Abstract Introduction Total self-reported sitting time is associated with higher risk for cardiometabolic disease and mortality,...

Back to Top