Balloon dilatation angioplasty: nonsurgical management of coarctation of the aorta.

View through CrossRef
Balloon dilatation angioplasty was successfully performed in five patients (ages 18 months to 17 years) with discrete aortic coarctation. The catheter size was No. 8F or 9F. Selection of balloon diameter was based on angiographic measurements of the aorta determined proximal and distal to the coarctation site. A 10 sec inflation-deflation cycle at 6 to 8 atmospheres (90 to 120 psi) was performed. The systolic pressure gradients across the coarctation before balloon dilatation angioplasty ranged from 35 to 70 mm Hg. Systolic pressure gradients after balloon dilatation angioplasty ranged from 0 to 10 mm Hg. All patients had normalized blood pressure immediately. Abnormal pulsed Doppler echocardiograms were observed in all patients before balloon dilatation angioplasty; four patients had normal echocardiograms after balloon dilatation angioplasty. No serious intraprocedural complications occurred. One patient required femoral artery thrombectomy 36 hr after balloon dilatation angioplasty. One to 6 months after balloon dilatation angioplasty no patients have evidence of restenosis of coarctation. Early results suggest that balloon dilatation angioplasty may offer a safe and effective nonsurgical alternative for the treatment of discrete coarctation in older infants and children. Long-term follow-up for the incidence of restenosis and formation of aneurysms will ultimately determine the efficacy and safety of this procedure.
Ovid Technologies (Wolters Kluwer Health)
Title: Balloon dilatation angioplasty: nonsurgical management of coarctation of the aorta.
Description:
Balloon dilatation angioplasty was successfully performed in five patients (ages 18 months to 17 years) with discrete aortic coarctation.
The catheter size was No.
8F or 9F.
Selection of balloon diameter was based on angiographic measurements of the aorta determined proximal and distal to the coarctation site.
A 10 sec inflation-deflation cycle at 6 to 8 atmospheres (90 to 120 psi) was performed.
The systolic pressure gradients across the coarctation before balloon dilatation angioplasty ranged from 35 to 70 mm Hg.
Systolic pressure gradients after balloon dilatation angioplasty ranged from 0 to 10 mm Hg.
All patients had normalized blood pressure immediately.
Abnormal pulsed Doppler echocardiograms were observed in all patients before balloon dilatation angioplasty; four patients had normal echocardiograms after balloon dilatation angioplasty.
No serious intraprocedural complications occurred.
One patient required femoral artery thrombectomy 36 hr after balloon dilatation angioplasty.
One to 6 months after balloon dilatation angioplasty no patients have evidence of restenosis of coarctation.
Early results suggest that balloon dilatation angioplasty may offer a safe and effective nonsurgical alternative for the treatment of discrete coarctation in older infants and children.
Long-term follow-up for the incidence of restenosis and formation of aneurysms will ultimately determine the efficacy and safety of this procedure.

Related Results

Assessing microstructural damage in paediatric aortic coarctation tissue during benchtop balloon angioplasty and stenting
Assessing microstructural damage in paediatric aortic coarctation tissue during benchtop balloon angioplasty and stenting
Abstract Endovascular stenting of native aortic coarctation has become standard treatment for children and young adults due to the shorter hospital stay and recover...
Immediate Outcomes of Balloon Angioplasty for Coarctation of the Aorta in infants and children
Immediate Outcomes of Balloon Angioplasty for Coarctation of the Aorta in infants and children
Background: Coarctation of the aorta (CoA) is one amongst commonest congenital heart diseases (CHD) which reuires early intervention to avoid morbidity and mortality. Balloon an...
Surgery versus Balloon angioplasty for treating coarctation of aorta: A meta-analysis
Surgery versus Balloon angioplasty for treating coarctation of aorta: A meta-analysis
Abstract Background In the past 50 years, therapeutic options for treating both children and adults with native aortic coarctat...
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract Introduction Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
S153 – Radiological Balloon Dilatation of Neo‐Pharyngeal Strictures
S153 – Radiological Balloon Dilatation of Neo‐Pharyngeal Strictures
ObjectivesRadiological balloon dilatation of lower oesophageal strictures is common practice. Other than some early reports from our own centre, there is little published regarding...
Stenting in Coarctation of the Aorta
Stenting in Coarctation of the Aorta
Narrowing of the aorta most commonly occurs in the region where the ductus arteriosus joins the aorta, i.e. at the isthmus just below the origin of the left subclavian artery. It i...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...

Back to Top