Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Predicting the Ideal Valve Size During Aortic Valve Replacement with Rapid Deployement Bioprosthetic Valves. Is Intraoperative Transesophageal Echocardiogram Reliable?

View through CrossRef
Objective: To describe experience with using intraoperative Transesophageal Echocardiography to reliably predict the size of the rapid deployment prosthetic valve by measuring the native aortic annulus Methods: Retrospective review of single institution series of patients undergoing Aortic Valve Replacement with Rapid Deployement Bioprosthetic Valves. Included were patients that had their native aortic valve replaced either isolated or as part of any additional procedure. Aortic annulus was measured prior to initiation of the operation using transesophageal echocardiography (TEE). Correlation analysis was conducted between Echocardiographic annular measurements and actual implanted valve sizes. Results: Twenty five patients underwent rapid deployment valve implantation in the aortic position. Of these, 36% of patients had the same size valve as the measured aortic annulus, 48% of patients had a valve implanted that was 1 mm different, and 16% of patients had 2 mm difference. The mean annular size based was 22.4 mm (range: 21-28 mm). The mean valve size implanted was 23.3 mm (range: 21-27 mm). There was no statistically significant difference between the mean annular measurement and the valve size selected (0.9 mm , p = 0.8). Conclusion: TEE can further enhance valve sizing and guidance through a proper and safe deployment. Although evident in our experience, larger scale studies are needed to further elucidate conclusions on the importance of avoiding under-sizing valves.
Title: Predicting the Ideal Valve Size During Aortic Valve Replacement with Rapid Deployement Bioprosthetic Valves. Is Intraoperative Transesophageal Echocardiogram Reliable?
Description:
Objective: To describe experience with using intraoperative Transesophageal Echocardiography to reliably predict the size of the rapid deployment prosthetic valve by measuring the native aortic annulus Methods: Retrospective review of single institution series of patients undergoing Aortic Valve Replacement with Rapid Deployement Bioprosthetic Valves.
Included were patients that had their native aortic valve replaced either isolated or as part of any additional procedure.
Aortic annulus was measured prior to initiation of the operation using transesophageal echocardiography (TEE).
Correlation analysis was conducted between Echocardiographic annular measurements and actual implanted valve sizes.
Results: Twenty five patients underwent rapid deployment valve implantation in the aortic position.
Of these, 36% of patients had the same size valve as the measured aortic annulus, 48% of patients had a valve implanted that was 1 mm different, and 16% of patients had 2 mm difference.
The mean annular size based was 22.
4 mm (range: 21-28 mm).
The mean valve size implanted was 23.
3 mm (range: 21-27 mm).
There was no statistically significant difference between the mean annular measurement and the valve size selected (0.
9 mm , p = 0.
8).
Conclusion: TEE can further enhance valve sizing and guidance through a proper and safe deployment.
Although evident in our experience, larger scale studies are needed to further elucidate conclusions on the importance of avoiding under-sizing valves.

Related Results

On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
<span style="font-size:11pt"><span style="background:#f9f9f4"><span style="line-height:normal"><span style="font-family:Calibri,sans-serif"><b><spa...
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
<p><em><span style="font-size: 11.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-langua...
Durability of Bioprosthetic and Mechanical Valves Implanted for Aortic Valve Replacement in Pediatric Patients
Durability of Bioprosthetic and Mechanical Valves Implanted for Aortic Valve Replacement in Pediatric Patients
BACKGROUND: There is limited published information on bioprosthetic aortic valve durability. The purpose of this study was to assess the durability of bioprosth...
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Transcatheter aortic valve replacement is a well-established treatment for high-surgical-risk patients with severe aortic disease, providing a less invasive alternative to traditio...
Cardiovascular MRI: A valuable tool to detect cardiac source of emboli in cryptogenic ischemic strokes
Cardiovascular MRI: A valuable tool to detect cardiac source of emboli in cryptogenic ischemic strokes
AbstractObjectivesDespite a thorough work‐up including transesophageal echocardiography, 20%–30% of stroke etiology remains cryptogenic. Transesophageal echocardiogram is considere...
Endocarditis risk with bioprosthetic and mechanical valves: systematic review and meta-analysis
Endocarditis risk with bioprosthetic and mechanical valves: systematic review and meta-analysis
Objective Bioprosthetic valves are being used with increased frequency for valve replacement, with controversy regarding risk:benefit ratio compared with mechanic...

Back to Top