Javascript must be enabled to continue!
Monitoring the improvement of muscle performance using isokinetic dynamometry: A comparative analysis based on the full range of motion vs. the valid isokinetic sector
View through CrossRef
BACKGROUND:
Isokinetic dynamometers measure moment and calculate work and power values, which are generally used to interpret muscle performance.
OBJECTIVE:
This study aimed to determine the differences of peak moment (PM), work, and power between FRoM and calculated valid isokinetic sector (VIS) data to define the possibility of the misinterpretation of isokinetic dynamometer data.
METHODS:
Fourteen professional male soccer players who had ACL reconstruction were recruited to the muscle strengthening program which was conducted four days a week for six weeks with increasing training intensity each week. Isokinetic muscle peak moment, work, and power of knee extensors and flexors were measured at angular velocities of 60, 120, 180 and 240
∘
/s.
RESULTS:
The results of the standard full-RoM (FRoM) report were compared with the calculated VIS data. Analyses of the FRoM data showed that PM, work, and power values for both extensor and flexor muscle groups improved significantly. However, a comparison of FRoM and VIS data showed significant differences for the work and power values at 120, 180 and 240
∘
/s.
CONCLUSION:
The evaluation of FRoM isokinetic data may cause improper interpretations in muscle performance, particularly for contractions with higher angular velocities.
Title: Monitoring the improvement of muscle performance using isokinetic dynamometry: A comparative analysis based on the full range of motion vs. the valid isokinetic sector
Description:
BACKGROUND:
Isokinetic dynamometers measure moment and calculate work and power values, which are generally used to interpret muscle performance.
OBJECTIVE:
This study aimed to determine the differences of peak moment (PM), work, and power between FRoM and calculated valid isokinetic sector (VIS) data to define the possibility of the misinterpretation of isokinetic dynamometer data.
METHODS:
Fourteen professional male soccer players who had ACL reconstruction were recruited to the muscle strengthening program which was conducted four days a week for six weeks with increasing training intensity each week.
Isokinetic muscle peak moment, work, and power of knee extensors and flexors were measured at angular velocities of 60, 120, 180 and 240
∘
/s.
RESULTS:
The results of the standard full-RoM (FRoM) report were compared with the calculated VIS data.
Analyses of the FRoM data showed that PM, work, and power values for both extensor and flexor muscle groups improved significantly.
However, a comparison of FRoM and VIS data showed significant differences for the work and power values at 120, 180 and 240
∘
/s.
CONCLUSION:
The evaluation of FRoM isokinetic data may cause improper interpretations in muscle performance, particularly for contractions with higher angular velocities.
Related Results
Poster 247: Muscle ERRγ Overexpression Mitigates the Muscle Atrophy after ACL injury
Poster 247: Muscle ERRγ Overexpression Mitigates the Muscle Atrophy after ACL injury
Objectives:
Anterior cruciate ligament (ACL) reconstruction is the 6th most common orthopedic procedure performed in the United States (1,2). There is substanti...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Validation of force production during quadriceps set exercise using a hand-held dynamometer: A comparative study with isokinetic dynamometry in healthy individuals
Validation of force production during quadriceps set exercise using a hand-held dynamometer: A comparative study with isokinetic dynamometry in healthy individuals
The study aim was to compare lower extremity muscle strength measurements obtained during the quadriceps set exercise in healthy individuals. Twenty-four healthy individuals (23.1±...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract
Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
Sex Differences in Muscle Fatigue Following Isokinetic Muscle Contractions
Sex Differences in Muscle Fatigue Following Isokinetic Muscle Contractions
Abstract
Muscle fatigue is a limiting factor of human performance. It is unclear whether sex-based differences in fatigability exist during dynamic exercise of varying velo...
Isokinetic Evaluation of the Hip Flexor and Extensor Muscles: A Systematic Review
Isokinetic Evaluation of the Hip Flexor and Extensor Muscles: A Systematic Review
Introduction:Isokinetic dynamometry testing is a safe and reliable method accepted as the “gold standard” in the evaluation of muscle strength in the open kinetic chain. Isokinetic...
5. All That glitters is not gold
5. All That glitters is not gold
Abstract
Introduction
Inflammatory muscle disease is a rare but well-recognised manifestation of systemic vasculitis. It can pre...
Reliability of Flywheel Hip Extension and Leg Curl Tests and Their Associations With Isokinetic Hamstring Strength
Reliability of Flywheel Hip Extension and Leg Curl Tests and Their Associations With Isokinetic Hamstring Strength
Flywheel (FW) resistance training is used to develop and monitor hamstring strength in team-sport athletes. The purpose of this study was to assess the between-session reliability ...

