Javascript must be enabled to continue!
Assessment of Atrial Electromechanical Delay by Tissue Doppler Echocardiography in Obese Subjects
View through CrossRef
Our aim was to evaluate whether atrial electromechanical delay measured by tissue Doppler imaging (TDI), which is an early predictor of atrial fibrillation (AF) development, is prolonged in obese subjects. A total of 40 obese and 40 normal‐weight subjects with normal coronary angiograms were included in this study. P‐wave dispersion (PWD) was calculated on the 12‐lead electrocardiogram (ECG). Systolic and diastolic left ventricular (LV) functions, inter‐ and intra‐atrial electromechanical delay were measured by TDI and conventional echocardiography. Inter‐ and intra‐atrial electromechanical delay were significantly longer in the obese subjects compared with the controls (44.08 ± 10.06 vs. 19.35 ± 5.94 ms and 23.63 ± 6.41 vs. 5.13 ± 2.67 ms, P < 0.0001 for both, respectively). PWD was higher in obese subjects (53.40 ± 5.49 vs. 35.95 ± 5.93 ms, P < 0.0001). Left atrial (LA) diameter, LA volume index and LV diastolic parameters were significantly different between the groups. Interatrial electromechanical delay was correlated with PWD (r = 0.409, P = 0.009), high‐sensitivity C‐reactive protein (hsCRP) levels (r = 0.588, P < 0.0001). Interatrial electromechanical delay was positively correlated with LA diameter, LA volume index, and LV diastolic function parameters consisting of mitral early wave (E) deceleration time (DT) and isovolumetric relaxation time (IVRT; r = 0.323, P = 0.042; r = 0.387, P = 0.014; r = 0.339, P = 0.033; r = 0.325, P = 0.041; respectively) and, negatively correlated with mitral early (E) to late (A) wave ratio (E/A) (r = −0.380, P = 0.016) and myocardial early‐to‐late diastolic wave ratio (Em/Am) (r = −0.326, P = 0.040). This study showed that atrial electromechanical delay is prolonged in obese subjects. Prolonged atrial electromechanical delay is due to provoked low‐grade inflammation as well as LA enlargement and early LV diastolic dysfunction in obese subjects.
Title: Assessment of Atrial Electromechanical Delay by Tissue Doppler Echocardiography in Obese Subjects
Description:
Our aim was to evaluate whether atrial electromechanical delay measured by tissue Doppler imaging (TDI), which is an early predictor of atrial fibrillation (AF) development, is prolonged in obese subjects.
A total of 40 obese and 40 normal‐weight subjects with normal coronary angiograms were included in this study.
P‐wave dispersion (PWD) was calculated on the 12‐lead electrocardiogram (ECG).
Systolic and diastolic left ventricular (LV) functions, inter‐ and intra‐atrial electromechanical delay were measured by TDI and conventional echocardiography.
Inter‐ and intra‐atrial electromechanical delay were significantly longer in the obese subjects compared with the controls (44.
08 ± 10.
06 vs.
19.
35 ± 5.
94 ms and 23.
63 ± 6.
41 vs.
5.
13 ± 2.
67 ms, P < 0.
0001 for both, respectively).
PWD was higher in obese subjects (53.
40 ± 5.
49 vs.
35.
95 ± 5.
93 ms, P < 0.
0001).
Left atrial (LA) diameter, LA volume index and LV diastolic parameters were significantly different between the groups.
Interatrial electromechanical delay was correlated with PWD (r = 0.
409, P = 0.
009), high‐sensitivity C‐reactive protein (hsCRP) levels (r = 0.
588, P < 0.
0001).
Interatrial electromechanical delay was positively correlated with LA diameter, LA volume index, and LV diastolic function parameters consisting of mitral early wave (E) deceleration time (DT) and isovolumetric relaxation time (IVRT; r = 0.
323, P = 0.
042; r = 0.
387, P = 0.
014; r = 0.
339, P = 0.
033; r = 0.
325, P = 0.
041; respectively) and, negatively correlated with mitral early (E) to late (A) wave ratio (E/A) (r = −0.
380, P = 0.
016) and myocardial early‐to‐late diastolic wave ratio (Em/Am) (r = −0.
326, P = 0.
040).
This study showed that atrial electromechanical delay is prolonged in obese subjects.
Prolonged atrial electromechanical delay is due to provoked low‐grade inflammation as well as LA enlargement and early LV diastolic dysfunction in obese subjects.
Related Results
Left atrial function assessment by speckle tracking echocardiography in low-risk atrial fibrillation patients
Left atrial function assessment by speckle tracking echocardiography in low-risk atrial fibrillation patients
Objective: To compare the left atrial function utilising speckle tracking echocardiography in patients with low-risk and high-risk non-valvular atrial fibrillation.Methods: The des...
Inter‐Relationships Between Atrial Flutter and Atrial Fibrillation
Inter‐Relationships Between Atrial Flutter and Atrial Fibrillation
It has been appreciated for a long time that atrial flutter and atrial fibrillation have a clinical relationship. Now, with the technological advances that permit more sophisticate...
The Influence of Subcutaneous and Visceral Adipocyte Geometries on Metabolic Parameters and Metabolic Regulating Hormones in Obese and Non-Obese Subjects
The Influence of Subcutaneous and Visceral Adipocyte Geometries on Metabolic Parameters and Metabolic Regulating Hormones in Obese and Non-Obese Subjects
Adipose tissue plays a pivotal role in endocrine and metabolic homeostasis. This study aimed to compare subcutaneous and visceral adipocyte measurements, including area, shortest d...
Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation
Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation
OBJECTIVE
To determine whether there is significant atrial or atrial appendage enlargement or functional remodelling as a result of one to two months of sustained...
Oxidative Stress in Non-Obese & Obese Young Healthy Adults
Oxidative Stress in Non-Obese & Obese Young Healthy Adults
Introduction: Obesity causes various diseases due to systemic oxidative stress. Young healthy obese are unaware of oxidative burden in their body. Total oxidant status (TOS) is a m...
P920Understanding arrhythmia mechanisms in patients with atrial septal defects
P920Understanding arrhythmia mechanisms in patients with atrial septal defects
Abstract
Background
Atrial arrhythmias represent a major cause of morbidity and hospitalization in patients with atrial septal d...
Serum visfatin levels in obese and non-obese individuals; A comparative cross-sectional study.
Serum visfatin levels in obese and non-obese individuals; A comparative cross-sectional study.
Objective: To compare serum visfatin levels in obese and non-obese individuals. Study Design: Cross-sectional study. Setting: District Head Quarter Hospital, Gujrat. Period: July 2...
Left atrial strain parameters are able to predict presence of atrial fibrillation
Left atrial strain parameters are able to predict presence of atrial fibrillation
Abstract
Background
Three-dimensional speckle-tracking echocardiography allows evaluation of left atrial function, left atrial f...

