Single pressure transducer probe for 3D flow measurements
View through CrossRef
A new method of measuring 3D flow with a single pressure transducer mounted inside the head of a single probe is presented in this paper. The 3D flow field around the hemispherical or ellipsoidal probe head is used to derive the 3D flow vector in virtual 5-sensor mode. A pressure tap located in the vicinity of the probe head connects the instantaneous pressure of the measurement volume to the pressure transducer. By turning the probe to five different positions around the axis of the stem, a set of five pressures is formed. The relevant flow parameters such as total and static pressure, yaw and pitch angle as well as Mach number are derived from these five pressures using the proposed calibration model. A selection of six different probe head geometries with different pressure tap positions have been manufactured and calibrated in a free jet facility in order to find the ideal probe geometry. The results of the steady probe calibration showed that the probe captures 3D flow at a slightly higher error band compared to other probe techniques such as pneumatic multiple hole probes. A summary of the achieved model accuracy for each probe is given. Finally, the calibration model can be extended to any single sensor cylindrical probe, provided that the pressure coefficient shows a measurable variation with pitch angle.
Title: Single pressure transducer probe for 3D flow measurements
Description:
A new method of measuring 3D flow with a single pressure transducer mounted inside the head of a single probe is presented in this paper.
The 3D flow field around the hemispherical or ellipsoidal probe head is used to derive the 3D flow vector in virtual 5-sensor mode.
A pressure tap located in the vicinity of the probe head connects the instantaneous pressure of the measurement volume to the pressure transducer.
By turning the probe to five different positions around the axis of the stem, a set of five pressures is formed.
The relevant flow parameters such as total and static pressure, yaw and pitch angle as well as Mach number are derived from these five pressures using the proposed calibration model.
A selection of six different probe head geometries with different pressure tap positions have been manufactured and calibrated in a free jet facility in order to find the ideal probe geometry.
The results of the steady probe calibration showed that the probe captures 3D flow at a slightly higher error band compared to other probe techniques such as pneumatic multiple hole probes.
A summary of the achieved model accuracy for each probe is given.
Finally, the calibration model can be extended to any single sensor cylindrical probe, provided that the pressure coefficient shows a measurable variation with pitch angle.
Related Results
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Analyzing Well Performance VII
Analyzing Well Performance VII
Introduction
Analyzing well performance is an important step toward increasing profits by improving production techniques. The analysis is made by field tests and...
Development of single sensor fast response pressure probes
Development of single sensor fast response pressure probes
Multi-sensor fast response pressure probes are often used in turbomachinery investigations. However, the size of multi-sensor probes are often larger than is ideal. This paper desc...
Pressure Analysis of DST Flow Period Or Slug Flow For Horizontal Wells In Homogeneous Reservoir
Pressure Analysis of DST Flow Period Or Slug Flow For Horizontal Wells In Homogeneous Reservoir
Abstract
By the transient pressure for horizontal well with constant flow rate and Duhamel's principle, this paper presents the method to calculate the transient ...
Research on acoustic control of coupled vibration system of transducers using acoustic surface and topological defect structures
Research on acoustic control of coupled vibration system of transducers using acoustic surface and topological defect structures
<sec>How to regulate the sound waves in the coupled vibration system of complex power ultrasonic transducers and design high-performance transducer systems has always been an...
Virtual four sensor fast response aerodynamic probe (FRAP®)
Virtual four sensor fast response aerodynamic probe (FRAP®)
This paper introduces the new fast response aerodynamic probe (FRAP®), which was recently developed at the ETH Zurich. The probe provides time-resolved, three-dimensional flow meas...
The Comparison of the Transducer Circuits for the Two-Phase Flow Conductivity Probe
The Comparison of the Transducer Circuits for the Two-Phase Flow Conductivity Probe
The void fraction of two-phase flow can be measured by conductivity probe due to the difference of conductivity between air and water. It’s difficult to detect the conductivity of ...
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
Determinants of Cerebrovascular Reserve in Patients with Significant Carotid Stenosis
Abstract
Introduction
In patients with 70% to 99% diameter carotid artery stenosis cerebral blood flow reserve may be protectiv...