Modeling of Marine Asynchronous Shaft Generator and Simulation of Subsynchronization State

View through CrossRef
The new type of marine asynchronous shaft generator has the advantages of adjustable excitation and power factor, compared to the traditional synchronous shaft generator, and has been widely used. However, the traditional synchronous shaft generator simulation system is still used in domestic ship power station simulators, which seriously restricts the renewal of crew training. In order to overcome the shortage of the simulation system of doubly fed shaft generator for ship power plant simulator, in this paper, the mathematical model of marine doubly fed shaft system is established for the first time, according to the characteristics of doubly fed machine and marine shaft generator. This paper realizes power decoupling by stator flux orientation and simulates and analyses the asynchronous shaft generator under subsynchronous working conditions. The changing trend of each physical quantity in the simulation waveform meets the mathematical relationships of the actual physical quantity, which proves the correctness of the mathematical model and lays a theoretical foundation for the development of the simulation system of asynchronous shaft generator.
Title: Modeling of Marine Asynchronous Shaft Generator and Simulation of Subsynchronization State
Description:
The new type of marine asynchronous shaft generator has the advantages of adjustable excitation and power factor, compared to the traditional synchronous shaft generator, and has been widely used.
However, the traditional synchronous shaft generator simulation system is still used in domestic ship power station simulators, which seriously restricts the renewal of crew training.
In order to overcome the shortage of the simulation system of doubly fed shaft generator for ship power plant simulator, in this paper, the mathematical model of marine doubly fed shaft system is established for the first time, according to the characteristics of doubly fed machine and marine shaft generator.
This paper realizes power decoupling by stator flux orientation and simulates and analyses the asynchronous shaft generator under subsynchronous working conditions.
The changing trend of each physical quantity in the simulation waveform meets the mathematical relationships of the actual physical quantity, which proves the correctness of the mathematical model and lays a theoretical foundation for the development of the simulation system of asynchronous shaft generator.

Related Results

Effect of Normalizing on Semi Float Axle Shaft Performance - Case Study
Effect of Normalizing on Semi Float Axle Shaft Performance - Case Study
The primary function of axle shaft in semi float rear axle is to transmit the power to wheels. These shafts would experience the torsional load along with bending load as well. Hen...
The Epidemiology of Infant Shaft Fractures of Femur or Humerus by Incidence, Birth, Accidents, and Other Causes
The Epidemiology of Infant Shaft Fractures of Femur or Humerus by Incidence, Birth, Accidents, and Other Causes
Abstract Background: Knowledge of femur and humerus shaft fractures during infancy is scarce. The purpose of this population-based registry study was to analyze both birth-...
Rock Mass Failure and Remedial Measures Implemented When Excavating Ultra-Deep Shaft Stations
Rock Mass Failure and Remedial Measures Implemented When Excavating Ultra-Deep Shaft Stations
ABSTRACT: This paper presents several geotechnical challenges experienced while excavating two shaft stations at the depths of 2490 m and 2550 m in highly stresse...
Analisis Penyebab Pecahnya Cylinder Liner pada Generator Engine di Kapal MV. Kali Mas
Analisis Penyebab Pecahnya Cylinder Liner pada Generator Engine di Kapal MV. Kali Mas
Globalization has spurred the growth of the transportation sector. In this context, maintenance of generators on ship machinery is essential to ensure smooth ship operations. The g...
Aeroderivative Gas Turbine Coupling Generator Redesign
Aeroderivative Gas Turbine Coupling Generator Redesign
A major failure event was experienced at a 44 MW plant powered by four aeroderivative gas turbines arranged in two units, property of the Federal Commission of Electricity (CFE). ...
Measurement and Simulation of Hydro-Generator’s Asynchronous Operation
Measurement and Simulation of Hydro-Generator’s Asynchronous Operation
The extended testing of hydro-generator with Pelton turbine (rated 35 MVA) was performed on a generator whose lifespan expired and it was going to be replaced. This was the perfect...
Analisa Pengaruh Tegangan Harmonik Terhadap Regulasi Tegangan Eksitasi Generator Satu Fasa
Analisa Pengaruh Tegangan Harmonik Terhadap Regulasi Tegangan Eksitasi Generator Satu Fasa
Esensinya setiap generator listrik satu fasa maupun tiga fasa telah dilengkapi dengan sistem eksitasi. Sistem eksitasi generator ada tiga, yaitu sistem eksitasi statis, dinamis, da...