Javascript must be enabled to continue!
Characteristics of large vestibular aqueduct syndrome in wideband acoustic immittance
View through CrossRef
ObjectiveTo describe the characteristics of large vestibular aqueduct syndrome (LVAS) in wideband acoustic immittance (WAI) and to explore whether inner ear deformity has an impact on WAI results.MethodsSubjects with typical LVAS (LVAS group) and control subjects with a normal anatomical structure of the inner ear (control group) were screened from pediatric patients with cochlear implants using thin-slice computed tomography (CT) images of the temporal bone. With inflammation of the auditory canal and middle ear excluded by routine ear examination and 226 Hz acoustic immittance, WAI data were acquired. Then, the maximum absorbance as the major observation indicator on the mean tympanogram was compared between the LVAS group and control group, and a descriptive comparison of the mean tympanogram and frequency-absorbance curve at peak pressure was performed between the two groups.ResultsThe LVAS group included 21 cases (38 ears), and the control group included 27 cases (45 ears). All LVAS subjects met the Valvassori criteria, and the VA at the horizontal semicircular canal displayed flared expansion. On the mean tympanogram, the maximum absorbance in the LVAS group (0.542 ± 0.087) was significantly higher than that in the control group (0.455 ± 0.087) (p < 0.001). The tympanogram in the LVAS group showed an overall elevation, and the absorbance at all pressure sampling points was significantly higher than that in the control group (p < 0.001). The frequency-absorbance curve at peak pressure first increased and then decreased in both groups, and the LVAS group showed higher absorbance than the control group in the frequency range below 2,828 Hz. The absorbance at 343–1,124 Hz was significantly different between the two groups (p < 0.001), and 343–1,124 Hz was the major frequency range at which the maximum absorbance on the mean tympanogram increased in the LVAS group.ConclusionLarge vestibular aqueduct syndrome (LVAS) shows increased absorbance in low and medium frequency ranges in WAI. The maximum absorbance on the mean tympanogram can serve as a reliable evaluation indicator. Inner ear factors must be considered when middle ear lesions are analyzed by WAI.
Frontiers Media SA
Title: Characteristics of large vestibular aqueduct syndrome in wideband acoustic immittance
Description:
ObjectiveTo describe the characteristics of large vestibular aqueduct syndrome (LVAS) in wideband acoustic immittance (WAI) and to explore whether inner ear deformity has an impact on WAI results.
MethodsSubjects with typical LVAS (LVAS group) and control subjects with a normal anatomical structure of the inner ear (control group) were screened from pediatric patients with cochlear implants using thin-slice computed tomography (CT) images of the temporal bone.
With inflammation of the auditory canal and middle ear excluded by routine ear examination and 226 Hz acoustic immittance, WAI data were acquired.
Then, the maximum absorbance as the major observation indicator on the mean tympanogram was compared between the LVAS group and control group, and a descriptive comparison of the mean tympanogram and frequency-absorbance curve at peak pressure was performed between the two groups.
ResultsThe LVAS group included 21 cases (38 ears), and the control group included 27 cases (45 ears).
All LVAS subjects met the Valvassori criteria, and the VA at the horizontal semicircular canal displayed flared expansion.
On the mean tympanogram, the maximum absorbance in the LVAS group (0.
542 ± 0.
087) was significantly higher than that in the control group (0.
455 ± 0.
087) (p < 0.
001).
The tympanogram in the LVAS group showed an overall elevation, and the absorbance at all pressure sampling points was significantly higher than that in the control group (p < 0.
001).
The frequency-absorbance curve at peak pressure first increased and then decreased in both groups, and the LVAS group showed higher absorbance than the control group in the frequency range below 2,828 Hz.
The absorbance at 343–1,124 Hz was significantly different between the two groups (p < 0.
001), and 343–1,124 Hz was the major frequency range at which the maximum absorbance on the mean tympanogram increased in the LVAS group.
ConclusionLarge vestibular aqueduct syndrome (LVAS) shows increased absorbance in low and medium frequency ranges in WAI.
The maximum absorbance on the mean tympanogram can serve as a reliable evaluation indicator.
Inner ear factors must be considered when middle ear lesions are analyzed by WAI.
Related Results
Relationship of Vestibular Aqueduct and Inner Ear Pressure in Ménière's Disease and the Normal Population
Relationship of Vestibular Aqueduct and Inner Ear Pressure in Ménière's Disease and the Normal Population
AbstractObjective Etiopathogenesis of Ménière's disease has not been resolved. The principal histopathologic finding in this disease is endolymphatic hydrops. The majority of radio...
Position of the Internal Aperture of Vestibular Aqueduct in Patients With Enlarged Vestibular Aqueduct
Position of the Internal Aperture of Vestibular Aqueduct in Patients With Enlarged Vestibular Aqueduct
Objective:
To investigate the position of the internal aperture of vestibular aqueduct and its relationship to hearing level in patients with enlarged vestibular aquedu...
Bithermal caloric test results and vestibular evoked myogenic potentials in patients with vestibular migraine
Bithermal caloric test results and vestibular evoked myogenic potentials in patients with vestibular migraine
Objectives:
The aim of this study was to study the ocular vestibular evoked myogenic potentials, cervical vestibular evoked myogenic potentials, and bithermal caloric t...
Identification of vestibular loss in children with sensorineural hearing loss using the balance subset of the BOT-2 test
Identification of vestibular loss in children with sensorineural hearing loss using the balance subset of the BOT-2 test
Abstract
Background
Vestibular loss in children with sensorineural hearing loss (SNHL) is quite high. Despite the high prevalence of vestibular loss...
Morphometric Study of the Vestibular Aqueduct in Patients With Enlarged Vestibular Aqueduct
Morphometric Study of the Vestibular Aqueduct in Patients With Enlarged Vestibular Aqueduct
Objective
To test whether there are significant differences in the morphologic features of the enlarged vestibular aqueduct (EVA) and its anatomic relationships with ad...
Vestibular-Evoked Cerebral Potentials
Vestibular-Evoked Cerebral Potentials
The human vestibular cortex has mostly been approached using functional magnetic resonance imaging and positron emission tomography combined with artificial stimulation of the vest...
FIVE-YEARS PREVALENCE OF VESTIBULAR DISORDERS, AS SEEN IN A TERTIARY CARE HOSPITAL
FIVE-YEARS PREVALENCE OF VESTIBULAR DISORDERS, AS SEEN IN A TERTIARY CARE HOSPITAL
Vestibular disorders can affect the peripheral or central vestibular systems, controlling and maintaining balance. Several studies have confirmed the high prevalence rate of vestib...
VESTIBULAR REHABILITATION EXERCISES SHOULD BE EFFECTIVE FIRST LINE TREATMENT INSTEAD OF MEDICATIONS IN PAKISTAN FOR BENIGN PAROXYSMAL POSITIONAL VERTIGO (BPPV)
VESTIBULAR REHABILITATION EXERCISES SHOULD BE EFFECTIVE FIRST LINE TREATMENT INSTEAD OF MEDICATIONS IN PAKISTAN FOR BENIGN PAROXYSMAL POSITIONAL VERTIGO (BPPV)
Dear Editor,
Let me divert your kind attention to the effectiveness of vestibular rehabilitation exercises (VRE) as the first-line treatment for benign paroxysmal positional vertig...

