Javascript must be enabled to continue!
Functional and Cosmetic Outcome after Reconstruction of Isolated, Unilateral Orbital Floor Fractures (Blow-Out Fractures) with and without the Support of 3D-Printed Orbital Anatomical Models
View through CrossRef
The present study aimed to analyze if a preformed “hybrid” patient-specific orbital mesh provides a more accurate reconstruction of the orbital floor and a better functional outcome than a standardized, intraoperatively adapted titanium implant. Thirty patients who had undergone surgical reconstruction for isolated, unilateral orbital floor fractures between May 2016 and November 2018 were included in this study. Of these patients, 13 were treated conventionally by intraoperative adjustment of a standardized titanium mesh based on assessing the fracture’s shape and extent. For the other 17 patients, an individual three-dimensional (3D) anatomical model of the orbit was fabricated with an in-house 3D-printer. This model was used as a template to create a so-called “hybrid” patient-specific titanium implant by preforming the titanium mesh before surgery. The functional and cosmetic outcome in terms of diplopia, enophthalmos, ocular motility, and sensory disturbance trended better when “hybrid” patient-specific titanium meshes were used but with statistically non-significant differences. The 3D-printed anatomical models mirroring the unaffected orbit did not delay the surgery’s timepoint. Nonetheless, it significantly reduced the surgery duration compared to the traditional method (58.9 (SD: 20.1) min versus 94.8 (SD: 33.0) min, p-value = 0.003). This study shows that using 3D-printed anatomical models as a supporting tool allows precise and less time-consuming orbital reconstructions with clinical benefits.
Title: Functional and Cosmetic Outcome after Reconstruction of Isolated, Unilateral Orbital Floor Fractures (Blow-Out Fractures) with and without the Support of 3D-Printed Orbital Anatomical Models
Description:
The present study aimed to analyze if a preformed “hybrid” patient-specific orbital mesh provides a more accurate reconstruction of the orbital floor and a better functional outcome than a standardized, intraoperatively adapted titanium implant.
Thirty patients who had undergone surgical reconstruction for isolated, unilateral orbital floor fractures between May 2016 and November 2018 were included in this study.
Of these patients, 13 were treated conventionally by intraoperative adjustment of a standardized titanium mesh based on assessing the fracture’s shape and extent.
For the other 17 patients, an individual three-dimensional (3D) anatomical model of the orbit was fabricated with an in-house 3D-printer.
This model was used as a template to create a so-called “hybrid” patient-specific titanium implant by preforming the titanium mesh before surgery.
The functional and cosmetic outcome in terms of diplopia, enophthalmos, ocular motility, and sensory disturbance trended better when “hybrid” patient-specific titanium meshes were used but with statistically non-significant differences.
The 3D-printed anatomical models mirroring the unaffected orbit did not delay the surgery’s timepoint.
Nonetheless, it significantly reduced the surgery duration compared to the traditional method (58.
9 (SD: 20.
1) min versus 94.
8 (SD: 33.
0) min, p-value = 0.
003).
This study shows that using 3D-printed anatomical models as a supporting tool allows precise and less time-consuming orbital reconstructions with clinical benefits.
Related Results
Hubungan antara tipe fraktur zygomaticomaxillary complex dengan gangguan fungsi bola mata, fraktur orbital floor dan tindakan bone graft di RSUP Prof. Dr. I.G.N.G. Ngoerah Denpasar
Hubungan antara tipe fraktur zygomaticomaxillary complex dengan gangguan fungsi bola mata, fraktur orbital floor dan tindakan bone graft di RSUP Prof. Dr. I.G.N.G. Ngoerah Denpasar
Introduction: A zygomaticomaxillary complex fracture is the most common facial fracture after a nose fracture. Serious eye injuries most often complicate these fractures and are al...
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Abstarct
Introduction
Orbital hydatid cysts (HCs) constitute less than 1% of all cases of hydatidosis, yet their occurrence is often linked to severe visual complications. This stu...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...
(087) Why Should Pelvic Floor Physical Therapy be Included in Treatment of Vestibulodynia?
(087) Why Should Pelvic Floor Physical Therapy be Included in Treatment of Vestibulodynia?
Abstract
Introduction
Vestibulodynia, vulvar pain localized to the vestibule without an identifiable cause, has a multifactorial...
Der skal ikke lades sten på sten tilbage
Der skal ikke lades sten på sten tilbage
The Building by the Barbar TempleClose by the large temple at Barbar 1) lies a little tell, which was investigated in the spring of 1956. The tell was shown to cover a building of ...
ANATOMY, EPIDEMIOLOGY, DIAGNOSIS, MANAGEMENT AND TREATMENT OF THE METACARPAL FRACTURES
ANATOMY, EPIDEMIOLOGY, DIAGNOSIS, MANAGEMENT AND TREATMENT OF THE METACARPAL FRACTURES
Introduction: The fracture of the neck of the fifth metacarpal, also known as boxers fracture, is one of the most frequent traumatic pathologies seen in the emergency department an...
Development and Evaluation of a Novel Anti-Ageing Cream Based on Hyaluronic Acid and Other Innovative Cosmetic Actives
Development and Evaluation of a Novel Anti-Ageing Cream Based on Hyaluronic Acid and Other Innovative Cosmetic Actives
The importance of incorporating hyaluronic acid (HA) as a cosmetic ingredient in skin care formulations emerged lately because the amount of HA naturally found in the epidermis dec...

