PERFORMANCE ANALYSIS OF A NONLINEAR AUTOMATIC GENERATION CONTROL FOR AN INTERCONNECTED ELECTRIC POWER SYSTEM USING FRACTIONAL ORDER SLIDING MODE CONTROL
View through CrossRef
The structure of the interconnected electric power system and the
increasing quality of energy have led to an increased importance of
Automatic Generation Control, or AGC. The tie line powers and frequency
must be maintained within the permitted standard values. This work
applies to Automatic Generation Control in a nonlinear model of an
interconnected electric power system using a fractional order sliding
mode controller. Three sections of a nonlinear interconnected electric
power system are controlled by a fractional order sliding mode
controller. The block diagram of the power plant model system considers
the nonlinearities that are physical limits, such as governor dead band
and generation rate constraints. In the presence of various load changes
(sudden load change frequency), parameter uncertainty (variation), and
the existence of physical constraints, the control’s goal is to manage
the frequency deviation (load frequency error) and tie-line power
deviation (tie-line power error) of the interconnected power system.
Three sections of an interconnected power system with nonlinearities are
used to simulate the fractional order sliding mode controller (FOSMC).
These designs display the best performance of the suggested FOSMC
controller, with numerical values for tie line power deviation of
2.9765e-5p.u. and frequency deviation of 6.8912e-4Hz. The suggested
system has reduced nominal values as compared to SMC for the frequency
deviation of 2.0762e-3Hz and tie line power deviation of 1.21754e-3p.u.,
as well as for PID controller frequency deviation of 3.5918e-3Hz and ti
line power deviation of 1.5602e-3p.u. These comparisons further
demonstrate that, even in the presence of parameter variation, load
changes, and nonlinearities in the system, FOSMC performs the best, with
reduced undershoot (5.4823e-4), overshoot (1.5545e-4), rising time
(1.00042e-8), and settling time (2.688). MATLAB/Simulink has been used
to create and simulate the controllers for the system model.
Title: PERFORMANCE ANALYSIS OF A NONLINEAR AUTOMATIC GENERATION CONTROL FOR AN INTERCONNECTED ELECTRIC POWER SYSTEM USING FRACTIONAL ORDER SLIDING MODE CONTROL
Description:
The structure of the interconnected electric power system and the
increasing quality of energy have led to an increased importance of
Automatic Generation Control, or AGC.
The tie line powers and frequency
must be maintained within the permitted standard values.
This work
applies to Automatic Generation Control in a nonlinear model of an
interconnected electric power system using a fractional order sliding
mode controller.
Three sections of a nonlinear interconnected electric
power system are controlled by a fractional order sliding mode
controller.
The block diagram of the power plant model system considers
the nonlinearities that are physical limits, such as governor dead band
and generation rate constraints.
In the presence of various load changes
(sudden load change frequency), parameter uncertainty (variation), and
the existence of physical constraints, the control’s goal is to manage
the frequency deviation (load frequency error) and tie-line power
deviation (tie-line power error) of the interconnected power system.
Three sections of an interconnected power system with nonlinearities are
used to simulate the fractional order sliding mode controller (FOSMC).
These designs display the best performance of the suggested FOSMC
controller, with numerical values for tie line power deviation of
2.
9765e-5p.
u.
and frequency deviation of 6.
8912e-4Hz.
The suggested
system has reduced nominal values as compared to SMC for the frequency
deviation of 2.
0762e-3Hz and tie line power deviation of 1.
21754e-3p.
u.
,
as well as for PID controller frequency deviation of 3.
5918e-3Hz and ti
line power deviation of 1.
5602e-3p.
u.
These comparisons further
demonstrate that, even in the presence of parameter variation, load
changes, and nonlinearities in the system, FOSMC performs the best, with
reduced undershoot (5.
4823e-4), overshoot (1.
5545e-4), rising time
(1.
00042e-8), and settling time (2.
688).
MATLAB/Simulink has been used
to create and simulate the controllers for the system model.
Related Results
Nonlinear optimal control for robotic exoskeletons with electropneumatic actuators
Nonlinear optimal control for robotic exoskeletons with electropneumatic actuators
Purpose
To provide high torques needed to move a robot’s links, electric actuators are followed by a transmission system with a high transmission rate. For instance, gear ratios of...
Solving Undamped and Damped Fractional Oscillators via Integral Rohit Transform
Solving Undamped and Damped Fractional Oscillators via Integral Rohit Transform
Background: The dynamics of fractional oscillators are generally described by fractional differential equations, which include the fractional derivative of the Caputo or Riemann-Li...
Decentralized control techniques applied to electric power distributed generation in microgrids
Decentralized control techniques applied to electric power distributed generation in microgrids
Distributed generation of electric energy has become part of the current electric power system. In this context a new scenario is arising in which small energy sources make up a ne...
Fractional Order Sliding Mode Controller Modelling for Fractional Order SEPIC Converter
Fractional Order Sliding Mode Controller Modelling for Fractional Order SEPIC Converter
DC/DC converters are power electronic devices that utilize passive
components such as resistors, capacitors, and inductors, along with
transistors to control the system through a d...
Smart Energy Management in Solar Systems Using Fuzzy Logic and Advanced Sliding Mode Control
Smart Energy Management in Solar Systems Using Fuzzy Logic and Advanced Sliding Mode Control
Abstract
This study proposes a fuel cell and electrolyzer-based energy storage system as an alternative to conventional battery storage for solar energy applications. The s...
Sliding conditions beneath the Antarctic Ice Sheet
Sliding conditions beneath the Antarctic Ice Sheet
<p>Computer models for ice sheet dynamics are the primary tools for making future predictions of ice sheet behaviour, the marine ice sheet instability, and ice sheet ...
Sliding Mode Controlled drives for wide speed operation of Threephase Induction Motor
Sliding Mode Controlled drives for wide speed operation of Threephase Induction Motor
Induction motor is widely used due to advantages in terms of performance, size, maintenance and efficiency compared to dc motor. Induction motor is either Scalar Controlled or Vect...
Research on chaos control of permanent magnet synchronous motor based on the synthetical sliding mode control of inverse system decoupling
Research on chaos control of permanent magnet synchronous motor based on the synthetical sliding mode control of inverse system decoupling
This article focuses on realizing the chaos control of a permanent magnet synchronous motor by combining a pseudo-linear inverse system of the permanent magnet synchronous motor an...