Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Enhancing cochlear duct length estimation by incorporating second-turn parameters

View through CrossRef
AbstractEstimating insertion depth, cochlear duct length (CDL), and other inner ear parameters is vital to optimizing cochlear implantation outcomes. Most current formulas use only the basal turn dimensions for CDL prediction. In this study, we investigated the importance of the second turn parameters in estimating CDL. Two experienced neuro-otologists blindly used segmentation software to measure (in mm) cochlear parameters, including basal turn diameter (A), basal turn width (B), second-turn diameter (A2), second-turn width (B2), CDL, first-turn length, and second-turn length (STL). These readings were taken from 33 computed tomography (CT) images of temporal bones from anatomically normal ears. We constructed regression models using A, B, A2, and B2 values fitted to CDL, two-turn length, and five-fold cross-validation to ensure model validity. CDL, A value, and STL were longer in males than in females. The mean B2/A2 ratio was 0.91 ± 0.06. Adding A2 and B2 values improved CDL prediction accuracy to 86.11%. Therefore, we propose a new formula for more accurate CDL estimation using A, B, A2, and B2 values. In conclusion, the findings of this study revealed a notable improvement in the prediction of two-turn length (2TL), and CDL by clinically appreciable margins upon adding A2 and B2 values to the prediction formulas.
Title: Enhancing cochlear duct length estimation by incorporating second-turn parameters
Description:
AbstractEstimating insertion depth, cochlear duct length (CDL), and other inner ear parameters is vital to optimizing cochlear implantation outcomes.
Most current formulas use only the basal turn dimensions for CDL prediction.
In this study, we investigated the importance of the second turn parameters in estimating CDL.
Two experienced neuro-otologists blindly used segmentation software to measure (in mm) cochlear parameters, including basal turn diameter (A), basal turn width (B), second-turn diameter (A2), second-turn width (B2), CDL, first-turn length, and second-turn length (STL).
These readings were taken from 33 computed tomography (CT) images of temporal bones from anatomically normal ears.
We constructed regression models using A, B, A2, and B2 values fitted to CDL, two-turn length, and five-fold cross-validation to ensure model validity.
CDL, A value, and STL were longer in males than in females.
The mean B2/A2 ratio was 0.
91 ± 0.
06.
Adding A2 and B2 values improved CDL prediction accuracy to 86.
11%.
Therefore, we propose a new formula for more accurate CDL estimation using A, B, A2, and B2 values.
In conclusion, the findings of this study revealed a notable improvement in the prediction of two-turn length (2TL), and CDL by clinically appreciable margins upon adding A2 and B2 values to the prediction formulas.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Presentation and Management of Cervical Thoracic Duct Cyst: A Systematic Review of the Literature
Presentation and Management of Cervical Thoracic Duct Cyst: A Systematic Review of the Literature
Abstract Introduction Thoracic duct cysts are an uncommon phenomenon, especially within the cervical region. Due to its limited reported cases, very little is known about its etiol...
The Effect of Cochlear Coverage on Auditory and Speech Performance in Cochlear Implant Patients
The Effect of Cochlear Coverage on Auditory and Speech Performance in Cochlear Implant Patients
Objective: To determine the effect of cochlear coverage on audiological and speech parameters in patients with cochlear implants. Previous work has investigated the eff...
The Therapeutic Dilemma of Cochlear Nerve Deficiency: Cochlear or Brainstem Implantation?
The Therapeutic Dilemma of Cochlear Nerve Deficiency: Cochlear or Brainstem Implantation?
ObjectiveTo compare the outcomes between 2 age‐matched cohorts of children with cochlear nerve deficiency: those receiving auditory brainstem implants (group A) or cochlear implant...
Isolated cystic duct cyst in a child :A case report
Isolated cystic duct cyst in a child :A case report
Abstract Background: Dilatation of the common bile duct is a common biliary malformation in children. However, isolated cysts of the cystic duct are extremely rare and not ...
Variations in Cystic Duct Anatomy Using Magnetic Resonance Cholangiopancreatography and their Clinical Significant in the Sudanese
Variations in Cystic Duct Anatomy Using Magnetic Resonance Cholangiopancreatography and their Clinical Significant in the Sudanese
Background: Anatomical variations of the cystic duct are very frequent, and it is substantial to be familiar with these variations preceding to any surgical, percutaneous and endos...
Salivary Mucocele Secondary to Parotid Duct Obstruction by Grass in a Dog
Salivary Mucocele Secondary to Parotid Duct Obstruction by Grass in a Dog
Background: Salivary mucocele results from the accumulation of saliva secondary to salivary gland or duct injury. Its etiology remains poorly understood, with limited reports on th...
Investigating the Electrical Properties of Different Cochlear Implants
Investigating the Electrical Properties of Different Cochlear Implants
Aim: This study characterises and compares electrical properties and current spread across four different makes of cochlear implants with differing electrode designs us...

Back to Top