Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Development of a new 3‐DOF parallel manipulator for minimally invasive surgery

View through CrossRef
AbstractThis article proposes a novel dexterous endoscopic parallel manipulator for minimally invasive surgery. The proposed manipulator has 3 degrees of freedom (3‐DOF), which consist of two rotational DOFs and one translational DOF (2R1T DOFs). The manipulator consists of 3 limbs exhibiting identical kinematic structure. Each limb contains an active prismatic joint followed by 2 consecutive passive universal joints. The proposed manipulator has a unique arrangement of its joints' axes. This unique arrangement permits large bending angles, ±90° in any direction, and a workspace almost free from interior singularities. These advantages allow the proposed manipulator to outperforms existing surgical manipulators. However, this unique arrangement makes the analysis of the robot extremely difficult. Therefore, a geometrical/analytical approach is used to facilitate its singularity analysis. Construction of the virtual prototype is accomplished using ADAMS software to validate the proposed manipulator and its bending capability. A closed‐form solution for inverse kinematics is obtained analytically. Also, the forward kinematics solution is obtained numerically. Moreover, evaluation of the workspace is achieved using motion/force transmissibility indices. A practical experiment has been performed using a scaling technique and PID controller. The experimental results show the feasibility of the teleoperated surgical system using the proposed parallel manipulator as the slave.
Title: Development of a new 3‐DOF parallel manipulator for minimally invasive surgery
Description:
AbstractThis article proposes a novel dexterous endoscopic parallel manipulator for minimally invasive surgery.
The proposed manipulator has 3 degrees of freedom (3‐DOF), which consist of two rotational DOFs and one translational DOF (2R1T DOFs).
The manipulator consists of 3 limbs exhibiting identical kinematic structure.
Each limb contains an active prismatic joint followed by 2 consecutive passive universal joints.
The proposed manipulator has a unique arrangement of its joints' axes.
This unique arrangement permits large bending angles, ±90° in any direction, and a workspace almost free from interior singularities.
These advantages allow the proposed manipulator to outperforms existing surgical manipulators.
However, this unique arrangement makes the analysis of the robot extremely difficult.
Therefore, a geometrical/analytical approach is used to facilitate its singularity analysis.
Construction of the virtual prototype is accomplished using ADAMS software to validate the proposed manipulator and its bending capability.
A closed‐form solution for inverse kinematics is obtained analytically.
Also, the forward kinematics solution is obtained numerically.
Moreover, evaluation of the workspace is achieved using motion/force transmissibility indices.
A practical experiment has been performed using a scaling technique and PID controller.
The experimental results show the feasibility of the teleoperated surgical system using the proposed parallel manipulator as the slave.

Related Results

ADVANCES AND CHALLENGES IN MINIMALLY INVASIVE SURGERY FOR THE TREATMENT OF HERNIAS
ADVANCES AND CHALLENGES IN MINIMALLY INVASIVE SURGERY FOR THE TREATMENT OF HERNIAS
Minimally invasive surgery has revolutionized the treatment of various medical conditions, offering significant benefits in terms of recovery and fewer complications. In the field ...
Clinical Effectiveness of Minimally Invasive Surgery on Spinal Trauma
Clinical Effectiveness of Minimally Invasive Surgery on Spinal Trauma
AIM: Minimally invasive spinal trauma surgery includes percutaneous pedicle screw fixation and miniature open anterolateral retractor-based approaches, which can improve surgical o...
Surgical Management of Spinal Metastases: Balancing Oncologic Control and Neurological Function
Surgical Management of Spinal Metastases: Balancing Oncologic Control and Neurological Function
Objective: To compare the outcomes of traditional and minimally invasive surgery in the treatment of spinal metastases, focusing on pain relief, neurological function, and oncologi...
Digital Oil Field; The NPDC Experience
Digital Oil Field; The NPDC Experience
Abstract This paper presents an overview of the implementation of a Digital Oilfield (DOF) system for the real-time management of the Oredo field in OML 111. ...
Oncological outcomes in minimally invasive gastric cancer surgery
Oncological outcomes in minimally invasive gastric cancer surgery
In the first part of this dissertation an assessment was made on current available evidence regarding outcomes in minimally invasive gastrectomy in comparison to open gastrectomy. ...
Motion Accuracy and Dynamic Responses of Dual-Manipulator on Spacecraft Considering Clearance Joints
Motion Accuracy and Dynamic Responses of Dual-Manipulator on Spacecraft Considering Clearance Joints
Clearance in joints caused by assemblage, manufacturing errors, and wear is inevitable, which will affect the dynamic performance of the dual-manipulator system on spacecraft. The ...

Back to Top