Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparative study of behaviour of reinforced concrete beam-column joints with reference to monolithic and non-monolithic connection

View through CrossRef
The implementation method of reinforced concrete construction has progressed very rapidly. This development aims to speed up time and reduce costs. One of the most widely used methods is the precast method, but the less popular precast method is used for simple storey buildings. Therefore, in this study the semi-precast method, which is easy to implement in a simple storey building, was presented. Parts of columns and beams were cast in place with different casting times. Therefore, the connection become non-monolithic. This study presented a comparison between the deflection and the static load capacity that can be received by the connection of reinforced concrete beam-column which is monolithically connected and non- monolithic. 3 sets of specimens were made to represent monolithic and non-monolithic specimens. The nonmonolithic specimens were made with 2 models, i.e. without and with a notch. The beam-column connections were tested experimentally and compared to the monolithic beam-column connection. The results showed that the notch on non-monolithic test specimens can increase the load capacity and reduce deflection compared to the specimen test without notch. The experimental results also showed that the strength and performance of structural non-monolithic beam-column connections were as good as those of monolithic beam-column joints.
Title: Comparative study of behaviour of reinforced concrete beam-column joints with reference to monolithic and non-monolithic connection
Description:
The implementation method of reinforced concrete construction has progressed very rapidly.
This development aims to speed up time and reduce costs.
One of the most widely used methods is the precast method, but the less popular precast method is used for simple storey buildings.
Therefore, in this study the semi-precast method, which is easy to implement in a simple storey building, was presented.
Parts of columns and beams were cast in place with different casting times.
Therefore, the connection become non-monolithic.
This study presented a comparison between the deflection and the static load capacity that can be received by the connection of reinforced concrete beam-column which is monolithically connected and non- monolithic.
3 sets of specimens were made to represent monolithic and non-monolithic specimens.
The nonmonolithic specimens were made with 2 models, i.
e.
without and with a notch.
The beam-column connections were tested experimentally and compared to the monolithic beam-column connection.
The results showed that the notch on non-monolithic test specimens can increase the load capacity and reduce deflection compared to the specimen test without notch.
The experimental results also showed that the strength and performance of structural non-monolithic beam-column connections were as good as those of monolithic beam-column joints.

Related Results

Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
The Effect of Some Parameters on Behaviour and Bearing Capacity of Multi-Drum Stone Columns under Static Load and Earthquake
The Effect of Some Parameters on Behaviour and Bearing Capacity of Multi-Drum Stone Columns under Static Load and Earthquake
In this thesis, the effect of several important parameters on the behaviour and bearing capacity of multi-drum stone columns loaded by short-term static loads and earthquakes was i...
He found use for reinforced concrete where, it would seem, this material has no place
He found use for reinforced concrete where, it would seem, this material has no place
Introduction. The article is devoted to an employee of the Research Institute of Reinforced Concrete, Doctor of Technical Sciences, Professor I.G. Ludkovsky, a specialist in the fi...
Performance comparison of beam-column joints with different concretes
Performance comparison of beam-column joints with different concretes
With the development of concrete materials, high strength concrete (HSC) and fiber reinforced concrete (FRC) are more and more used in reinforced concrete frame structures. This pa...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Lectin C gene analysis v1
Lectin C gene analysis v1
Mammalian Tissue Total RNA Purification Protocol by GeneJET RNA Purification Kit (Thermo Scientific, USA) Before starting: • Supplement the required amount of Lysis Buffer with β-...
A Comparative Study of the Design Basis for Complex Tubular Joints
A Comparative Study of the Design Basis for Complex Tubular Joints
ABSTRACT This paper describes a comparative study of the design basis for ring-stiffened, cast steel and internal grouted tubular joints. The current levels of kn...
SCF Equations for T/Y and K Square-to-Round Tubular Joint
SCF Equations for T/Y and K Square-to-Round Tubular Joint
Summary A parametric stress analysis of T/Y and K square-to-round tubular joints subjected to axial loads and in-plane and out-of-plane bending moments has been p...

Back to Top