Javascript must be enabled to continue!
A prospective, pragmatic non‐inferiority study of emergency intubation success with the single‐use i‐view versus standard reusable video laryngoscope
View through CrossRef
AbstractIntroductionVideo laryngoscope (VL) technology improves first‐pass success. The novel i‐view VL device is inexpensive and disposable. We sought to determine the first‐pass intubation success with the i‐view VL device versus the standard reusable VL systems in routine use at each site.MethodsWe performed a prospective, pragmatic study at two major emergency departments (EDs) when VL was used. We rotated i‐view versus reusable VL as the preferred device of the month based on an a priori schedule. An investigator‐initiated interim analysis was performed. Our primary outcome was a first‐pass success with a non‐inferiority margin of 10% based on the per‐protocol analysis.ResultsThere were 93 intubations using the reusable VL devices and 81 intubations using the i‐view. Our study was stopped early due to futility in reaching our predetermined non‐inferiority margin. Operator and patient characteristics were similar between the two groups. The first‐pass success rate for the i‐view group was 69.1% compared to 84.3% for the reusable VL group. A non‐inferiority analysis indicated that the difference (−15.1%) and corresponding 90% confidence limits (−25.3% to −5.0%) did not fall within the predetermined 10% non‐inferiority margin.ConclusionsThe i‐view device failed to meet our predetermined non‐inferiority margin when compared to the reusable VL systems with the study stopping early due to futility. Significant crossover occurred at the discretion of the intubating operator during the i‐view month.
Title: A prospective, pragmatic non‐inferiority study of emergency intubation success with the single‐use i‐view versus standard reusable video laryngoscope
Description:
AbstractIntroductionVideo laryngoscope (VL) technology improves first‐pass success.
The novel i‐view VL device is inexpensive and disposable.
We sought to determine the first‐pass intubation success with the i‐view VL device versus the standard reusable VL systems in routine use at each site.
MethodsWe performed a prospective, pragmatic study at two major emergency departments (EDs) when VL was used.
We rotated i‐view versus reusable VL as the preferred device of the month based on an a priori schedule.
An investigator‐initiated interim analysis was performed.
Our primary outcome was a first‐pass success with a non‐inferiority margin of 10% based on the per‐protocol analysis.
ResultsThere were 93 intubations using the reusable VL devices and 81 intubations using the i‐view.
Our study was stopped early due to futility in reaching our predetermined non‐inferiority margin.
Operator and patient characteristics were similar between the two groups.
The first‐pass success rate for the i‐view group was 69.
1% compared to 84.
3% for the reusable VL group.
A non‐inferiority analysis indicated that the difference (−15.
1%) and corresponding 90% confidence limits (−25.
3% to −5.
0%) did not fall within the predetermined 10% non‐inferiority margin.
ConclusionsThe i‐view device failed to meet our predetermined non‐inferiority margin when compared to the reusable VL systems with the study stopping early due to futility.
Significant crossover occurred at the discretion of the intubating operator during the i‐view month.
Related Results
Comparison of king vision video laryngoscope versus mccoy laryngoscope for endotracheal intubation in patients with immobilized cervical spine
Comparison of king vision video laryngoscope versus mccoy laryngoscope for endotracheal intubation in patients with immobilized cervical spine
Background: Objective of this study was to compare King vision video laryngoscope versus McCoy laryngoscope for endotracheal intubation in patients with simulated immobilized cervi...
COMPARATIVE EVALUATION OF AIRTRAQ OPTICAL LARYNGOSCOPE AND HUGE MED VIDEO LARYNGOSCOPE FOR LARYNGEAL VISUALISATION AND ENDOTRACHEAL INTUBATION IN ADULTS WITH ANTICIPATED DIFFICULT INTUBATION
COMPARATIVE EVALUATION OF AIRTRAQ OPTICAL LARYNGOSCOPE AND HUGE MED VIDEO LARYNGOSCOPE FOR LARYNGEAL VISUALISATION AND ENDOTRACHEAL INTUBATION IN ADULTS WITH ANTICIPATED DIFFICULT INTUBATION
Background and Aims: Complications arising from difficult or failed tracheal intubation still remains a leading cause of anaesthetic morbidity and mortality.This has lead to develo...
Comparison of Airtraq® Laryngoscope, Bonfils Endoscope and Fiberoptic Bronchoscope for Awake Tracheal Intubation: A Randomized, Controlled Trial
Comparison of Airtraq® Laryngoscope, Bonfils Endoscope and Fiberoptic Bronchoscope for Awake Tracheal Intubation: A Randomized, Controlled Trial
Over the last decades several indirect laryngoscopes have been developed to provide a significant better glottic view and improved the success rate in difficult intubations. Some c...
DirEct versus VIdeo LaryngosCopE (DEVICE): protocol and statistical analysis plan for a randomised clinical trial in critically ill adults undergoing emergency tracheal intubation
DirEct versus VIdeo LaryngosCopE (DEVICE): protocol and statistical analysis plan for a randomised clinical trial in critically ill adults undergoing emergency tracheal intubation
IntroductionAmong critically ill patients undergoing orotracheal intubation in the emergency department (ED) or intensive care unit (ICU), failure to visualise the vocal cords and ...
Comparison Between C-MAC Blade D Video Laryngoscope and Macintosh Laryngoscope for Insertion of Double Lumen Tube in Patients Undergoing Elective Thoracic Surgeries
Comparison Between C-MAC Blade D Video Laryngoscope and Macintosh Laryngoscope for Insertion of Double Lumen Tube in Patients Undergoing Elective Thoracic Surgeries
The insertion of a double lumen tube (DLT) for lung isolation during thoracic surgeries is technically challenging and may be associated with airway trauma and significant hemodyna...
Proficiencies of military medical officers in intubating difficult airways
Proficiencies of military medical officers in intubating difficult airways
Abstract
Background
This study sheds light on the proficiency of military medical officers who had received between 2 and...
Proficiencies of Military Medical Officers in Intubating Difficult Airways
Proficiencies of Military Medical Officers in Intubating Difficult Airways
Abstract
Background This study sheds light on the proficiency of military medical officers who had received between 2-3 years of post-graduate training, in the handling of ...
Proficiencies of Military Medical Officers in Intubating Difficult Airways
Proficiencies of Military Medical Officers in Intubating Difficult Airways
Abstract
Background This study sheds light on the proficiency of military medical officers who had received between 2-3 years of post-graduate training, in the handling of ...

