Javascript must be enabled to continue!
A New Paper-Based Microfluidic Design (µPAD) for the Determination of Total Phenols in Wastewater Using a Smartphone Sensor as a Detector
View through CrossRef
Phenols are well-known noxious compounds, that are often found in various water sources. In this research, a new method was used to determine the total phenol by using microfluidic paper-based (µPAD), with a smartphone Sensor. It is portable, inexpensive, and environmentally friendly. The paper was prepared using filter paper by the cutting method. The reagent was dried on the paper. The color sensor of the smartphone device was used as the color intensity sensor of the samples through the images captured by the smartphone through software downloaded to the phone. The focus of the samples is measured from the RGB value of the images taken from the (iPhone 14) device, where each image represents a specific focus. The calibration curve for this method was in the range of M (0.00016–0.5), the correlation coefficient (R2) was equal to (0.9753), the limit of detection was in the amount of (0.000032) M, and the relative standard deviation (RSD%) for the concentration was (0.02) M, for which the examination was repeated (10) times and its value was (0 %), and the recovery value (Recovery%) was equal to (100 %). The method was successfully applied for the determination of total phenols in wastewater.
Title: A New Paper-Based Microfluidic Design (µPAD) for the Determination of Total Phenols in Wastewater Using a Smartphone Sensor as a Detector
Description:
Phenols are well-known noxious compounds, that are often found in various water sources.
In this research, a new method was used to determine the total phenol by using microfluidic paper-based (µPAD), with a smartphone Sensor.
It is portable, inexpensive, and environmentally friendly.
The paper was prepared using filter paper by the cutting method.
The reagent was dried on the paper.
The color sensor of the smartphone device was used as the color intensity sensor of the samples through the images captured by the smartphone through software downloaded to the phone.
The focus of the samples is measured from the RGB value of the images taken from the (iPhone 14) device, where each image represents a specific focus.
The calibration curve for this method was in the range of M (0.
00016–0.
5), the correlation coefficient (R2) was equal to (0.
9753), the limit of detection was in the amount of (0.
000032) M, and the relative standard deviation (RSD%) for the concentration was (0.
02) M, for which the examination was repeated (10) times and its value was (0 %), and the recovery value (Recovery%) was equal to (100 %).
The method was successfully applied for the determination of total phenols in wastewater.
Related Results
The Best Phone Store, Intelligent Recommendation System for Smartphone Selection
The Best Phone Store, Intelligent Recommendation System for Smartphone Selection
Abstract— Nowadays, smartphones are a primary item that is needed by almost everyone, from children to adults. The large number of smartphones on the market makes it difficult for ...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Microfluidic Acoustic Metamaterial SAW Based Sensor
Microfluidic Acoustic Metamaterial SAW Based Sensor
Introduction. Microacoustic sensors based on surface acoustic wave (SAW) devices allow the sensor integration into a wafer based microfluidic analytical platforms such as lab-on-a-...
Characterization of a novel HgCdTe focal plane array for ground and space astronomy through innovative infrared setups
Characterization of a novel HgCdTe focal plane array for ground and space astronomy through innovative infrared setups
(English) Nowadays, mercury-cadmium-telluride (MCT) short-wave infrared (SWIR) detectors are widely used in cutting-edge space
missions and ground-based telescopes. They take adva...
Development of a paper-based microfluidic device for the quantification of ammonia in industrial wastewater
Development of a paper-based microfluidic device for the quantification of ammonia in industrial wastewater
Ammonia is a toxic pollutant increasingly found in urban and industrial wastewater and unprotected surface water. Industry discharges and fertilizer run-off release ammonia into se...
Conceptual design report of the MPD Cosmic Ray Detector (MCORD)
Conceptual design report of the MPD Cosmic Ray Detector (MCORD)
Abstract
This report presents a concept of constructing a detector
dedicated for detection of muons observed during measurements
carried out at the MPD (Multi-Pu...
A Trianalyte µPAD for Simultaneous Determination of Iron, Zinc, and Manganese Ions
A Trianalyte µPAD for Simultaneous Determination of Iron, Zinc, and Manganese Ions
In this work, a microfluidic paper-based analytical device (µPAD) for simultaneous detection of Fe, Zn, and Mn ions using immobilized chromogenic reagents Ferene S, xylenol orange,...
How can digital citizen science approaches improve ethical smartphone use surveillance among youth: traditional surveys versus ecological momentary assessments
How can digital citizen science approaches improve ethical smartphone use surveillance among youth: traditional surveys versus ecological momentary assessments
Abstract
Background
Ubiquitous use of smartphones among youth poses significant challenges related to non-communicable diseases...