Javascript must be enabled to continue!
Non-contact and non-constraining monitoring of the respiratory rate including sleep disordered breathing using ultra-wideband radar
View through CrossRef
AbstractBackgroundThe respiratory rate (RR) is a critical vital sign controlled by not only metabolic factors but behavior while awake. The prevalence of obstructive sleep apnea (OSA) is remarkably high. Therefore, a non-constraining and non-contact respiratory monitor to measure the RR both while awake and asleep is preferable.MethodsA millimeter wave radar (MWR) device was used for RR monitoring of participants suspected of OSA while awake (supine before and after polysomnography [PSG], sitting, and positioned on both sides) and asleep. Apnea and hypopnea during 1 hour of sleep (AHI) by PSG was compared with 1 hour of respiratory events (REI) judged by MWR. Portable monitoring (PM) and percutaneous arterial O2(SpO2) monitoring were done simultaneously.ResultsCorrelations between the RR by MWR and respiratory inductance plethysmography at PSG while awake in every measured position including the supine position before and after PSG were very high (r=0.92∼0.99) (n=60). The REI by MWR were significantly correlated with AHI determined by PSG, PM, or SpO2monitoring (p<0.001). Brand-Altman plot showed that the MWR for AHI monitoring was acceptable. Predicted AHI by MWR relative to PSG was almost the same as with PM or SpO2monitoring.ConclusionsThe developed MWR respiratory monitor was useful during wakefulness and sleep, including detection of apnea and hypopnea. This system can be useful in multiple medical settings such as critical care with and without sleep apnea, pandemic infection, elder care at home, etc. Trial registration number: UMIN000045833 (http://www.umin/ac.jp)
Title: Non-contact and non-constraining monitoring of the respiratory rate including sleep disordered breathing using ultra-wideband radar
Description:
AbstractBackgroundThe respiratory rate (RR) is a critical vital sign controlled by not only metabolic factors but behavior while awake.
The prevalence of obstructive sleep apnea (OSA) is remarkably high.
Therefore, a non-constraining and non-contact respiratory monitor to measure the RR both while awake and asleep is preferable.
MethodsA millimeter wave radar (MWR) device was used for RR monitoring of participants suspected of OSA while awake (supine before and after polysomnography [PSG], sitting, and positioned on both sides) and asleep.
Apnea and hypopnea during 1 hour of sleep (AHI) by PSG was compared with 1 hour of respiratory events (REI) judged by MWR.
Portable monitoring (PM) and percutaneous arterial O2(SpO2) monitoring were done simultaneously.
ResultsCorrelations between the RR by MWR and respiratory inductance plethysmography at PSG while awake in every measured position including the supine position before and after PSG were very high (r=0.
92∼0.
99) (n=60).
The REI by MWR were significantly correlated with AHI determined by PSG, PM, or SpO2monitoring (p<0.
001).
Brand-Altman plot showed that the MWR for AHI monitoring was acceptable.
Predicted AHI by MWR relative to PSG was almost the same as with PM or SpO2monitoring.
ConclusionsThe developed MWR respiratory monitor was useful during wakefulness and sleep, including detection of apnea and hypopnea.
This system can be useful in multiple medical settings such as critical care with and without sleep apnea, pandemic infection, elder care at home, etc.
Trial registration number: UMIN000045833 (http://www.
umin/ac.
jp).
Related Results
0864 Severe Central Sleep Apnea
0864 Severe Central Sleep Apnea
Abstract
Introduction
Central sleep apnea (CSA) is a rare form of sleep disordered breathing with repeated apneic episodes with ...
Ultra-wideband ultra-short pulse communication system
Ultra-wideband ultra-short pulse communication system
Problem statement. The development and design of radio communication systems with enhanced structural and energy stealth properties are of the greatest interest in modern radio eng...
The effect of breathing exercises on adults' sleep quality: an intervention that works
The effect of breathing exercises on adults' sleep quality: an intervention that works
This study investigates the application of various breathing exercises to enhance sleep quality. Respiration is an indispensable aspect of life that significantly influences both t...
The history of sleep research and sleep medicine in Europe
The history of sleep research and sleep medicine in Europe
SummarySleep became a subject of scientific research in the second half of the 19th century. Since sleep, unlike other physiological functions, cannot be attributed to a specific o...
Deep sleep homeostatic response to naturalistic sleep loss
Deep sleep homeostatic response to naturalistic sleep loss
Abstract
Introduction
Investigations of sleep homeostasis often involve tightly controlled experimental sleep deprivation in se...
Median Preoptic Astrocytes: Role in Sleep Regulation and Potential Mediators of Sex Differences
Median Preoptic Astrocytes: Role in Sleep Regulation and Potential Mediators of Sex Differences
One in three Americans suffer from chronic sleep disorders, and women are 40% more likely than men to experience sleep disorders. This disparity emerges at puberty and is strongly ...
Sleep and neurobehavioral performance during a 14-day laboratory study of split sleep/wake schedules for space operations
Sleep and neurobehavioral performance during a 14-day laboratory study of split sleep/wake schedules for space operations
This laboratory study of 90 healthy adults investigates human performance impairments resulting from sleep restriction in order to examine whether splitting sleep into a shortened ...
Reward does not facilitate visual perceptual learning until sleep occurs
Reward does not facilitate visual perceptual learning until sleep occurs
ABSTRACTA growing body of evidence indicates that visual perceptual learning (VPL) is enhanced by reward provided during training. Another line of studies has shown that sleep foll...