In this article a luminescence fiber optic biosensor for the microdetection of heavy metal toxicity in waters based on the marine bacterium Aliivibrio fischeri (A. fischeri) encapsulated in alginate microspheres is described. Cu(II), Cd(II), Pb(II), Zn(II), Cr(VI), Co(II), Ni(II), Ag(I) and Fe(II) were selected as sample toxic heavy metal ions for evaluation of the performance of this toxicity microbiosensor. The loss of bioluminescence response from immobilized A. fischeri bacterial cells corresponds to changes in the toxicity levels. The inhibition of the luminescent biosensor response collected at excitation and emission wavelengths of 287 ± 2 nm and 487 ± 2 nm, respectively, was found to be reproducible and repeatable within the relative standard deviation (RSD) range of 2.4–5.7% (n = 8). The toxicity biosensor based on alginate micropsheres exhibited a lower limit of detection (LOD) for Cu(II) (6.40 μg/L), Cd(II) (1.56 μg/L), Pb(II) (47 μg/L), Ag(I) (18 μg/L) than Zn(II) (320 μg/L), Cr(VI) (1,000 μg/L), Co(II) (1700 μg/L), Ni(II) (2800 μg/L), and Fe(III) (3100 μg/L). Such LOD values are lower when compared with other previous reported whole cell toxicity biosensors using agar gel, agarose gel and cellulose membrane biomatrices used for the immobilization of bacterial cells. The A. fischeri bacteria microencapsulated in alginate biopolymer could maintain their metabolic activity for a prolonged period of up to six weeks without any noticeable changes in the bioluminescence response. The bioluminescent biosensor could also be used for the determination of antagonistic toxicity levels for toxicant mixtures. A comparison of the results obtained by atomic absorption spectroscopy (AAS) and using the proposed luminescent A. fischeri-based biosensor suggests that the optical toxicity biosensor can be used for quantitative microdetermination of heavy metal toxicity in environmental water samples.
Title: Microencapsulated Aliivibrio fischeri in Alginate Microspheres for Monitoring Heavy Metal Toxicity in Environmental Waters
Description:
In this article a luminescence fiber optic biosensor for the microdetection of heavy metal toxicity in waters based on the marine bacterium Aliivibrio fischeri (A.
fischeri) encapsulated in alginate microspheres is described.
Cu(II), Cd(II), Pb(II), Zn(II), Cr(VI), Co(II), Ni(II), Ag(I) and Fe(II) were selected as sample toxic heavy metal ions for evaluation of the performance of this toxicity microbiosensor.
The loss of bioluminescence response from immobilized A.
fischeri bacterial cells corresponds to changes in the toxicity levels.
The inhibition of the luminescent biosensor response collected at excitation and emission wavelengths of 287 ± 2 nm and 487 ± 2 nm, respectively, was found to be reproducible and repeatable within the relative standard deviation (RSD) range of 2.
4–5.
7% (n = 8).
The toxicity biosensor based on alginate micropsheres exhibited a lower limit of detection (LOD) for Cu(II) (6.
40 μg/L), Cd(II) (1.
56 μg/L), Pb(II) (47 μg/L), Ag(I) (18 μg/L) than Zn(II) (320 μg/L), Cr(VI) (1,000 μg/L), Co(II) (1700 μg/L), Ni(II) (2800 μg/L), and Fe(III) (3100 μg/L).
Such LOD values are lower when compared with other previous reported whole cell toxicity biosensors using agar gel, agarose gel and cellulose membrane biomatrices used for the immobilization of bacterial cells.
The A.
fischeri bacteria microencapsulated in alginate biopolymer could maintain their metabolic activity for a prolonged period of up to six weeks without any noticeable changes in the bioluminescence response.
The bioluminescent biosensor could also be used for the determination of antagonistic toxicity levels for toxicant mixtures.
A comparison of the results obtained by atomic absorption spectroscopy (AAS) and using the proposed luminescent A.
fischeri-based biosensor suggests that the optical toxicity biosensor can be used for quantitative microdetermination of heavy metal toxicity in environmental water samples.

Related Results

A Review on the Synergistic Approaches for Heavy Metals Bioremediation: Harnessing the Power of Plant-Microbe Interactions
A Review on the Synergistic Approaches for Heavy Metals Bioremediation: Harnessing the Power of Plant-Microbe Interactions
Heavy metals contamination is a serious threat to all life forms. Long term exposure of heavy metals can lead to different life-threatening medical conditions including cancers of ...
Molecular Bird Sexing on Fischeri Lovebird (Agapornis fischeri) by Using Polymerase Chain Reaction
Molecular Bird Sexing on Fischeri Lovebird (Agapornis fischeri) by Using Polymerase Chain Reaction
Fischeri Lovebird (Agapornis fischeri) found originally in Africa which has spread to many countries. In Indonesia, Fischeri Lovebird is popular as a pet animal. This lovebird is a...
Characterization of chitosan/alginate/lovastatin nanoparticles and investigation of their toxic effects in vitro and in vivo
Characterization of chitosan/alginate/lovastatin nanoparticles and investigation of their toxic effects in vitro and in vivo
AbstractIn this study, chitosan and alginate were selected to prepare alginate/chitosan nanoparticles to load the drug lovastatin by the ionic gelation method. The synthesized nano...
Formulation and evaluation of Zidovudine alginate microspheres
Formulation and evaluation of Zidovudine alginate microspheres
The objective of the  present  study  was  to  prepare  and  evaluate  microspheres  for  the controlled release of Zidovudine from the prepared microspheres using different polyme...
Development of Gelatin-Thai Silk Fibroin Microspheres for Three Dimensional Cell Culture
Development of Gelatin-Thai Silk Fibroin Microspheres for Three Dimensional Cell Culture
Microspheres have been widely used for tissue engineering scaffolds. Microspheres have many advantages over the macrostructure such as high surface area for cell adhesion and proli...
Mucuna gum microspheres for oral delivery of glibenclamide: In vitro evaluation
Mucuna gum microspheres for oral delivery of glibenclamide: In vitro evaluation
Mucuna gum microspheres for oral delivery of glibenclamide:In vitroevaluationAn investigation into the suitability of mucuna gum microspheres for oral delivery of glibenclamide is ...

Back to Top