Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Safety of the Esmarch Tourniquet

View through CrossRef
The use of an Esmarch bandage as a tourniquet in surgery has been criticized. Many authors claim that the pressures under the Esmarch are inconsistent and may be extremely high. We have seen few, if any, problems from the use of an Esmarch in surgery of the foot and ankle. The purpose of this study was to evaluate the pressures generated under the Esmarch tourniquet in a situation that mimics its clinical application, and to determine whether pressures of appropriate magnitude and consistency are obtained in order to recommend its continued use in surgery. Ten volunteers performed numerous applications of the Esmarch. The number of wraps and the width of the Esmarch bandage used were varied. The Esmarch was applied as it would be for a surgical case. Pressures directly beneath the Esmarch were recorded 8 cm proximal to the distal tip of the medial malleolus. Considering all volunteers and all pressures generated, a 3-in Esmarch applied with three wraps gave a mean pressure (±SD) of 225 ± 46 mm Hg. A 3-in Esmarch applied with four wraps gave a mean pressure of 291 ± 53 mm Hg. A 4-in Esmarch applied with three wraps gave a mean pressure of 233 ± 35 mm Hg, and a 4-in Esmarch with four wraps gave a mean pressure of 284 ± 42 mm Hg. The maximum pressures generated by any individual were as follows: 3-in three wraps, 321 mm Hg; 3-in four wraps, 413 mm Hg; 4-in three wraps, 328 mm Hg; and 4-in four wraps, 380 mm Hg. There was no significant difference in the magnitude or consistency of pressures generated between the experienced and inexperienced wrappers. There did not appear to be a learning curve for the application of the Esmarch bandage. We conclude that an Esmarch bandage, used as a tourniquet, can generate safe and reliable pressures. Either a 3-in or 4-in Esmarch bandage applied above the ankle with three circumferential overlapping wraps consistently results in pressures that are in a safe range.
Title: The Safety of the Esmarch Tourniquet
Description:
The use of an Esmarch bandage as a tourniquet in surgery has been criticized.
Many authors claim that the pressures under the Esmarch are inconsistent and may be extremely high.
We have seen few, if any, problems from the use of an Esmarch in surgery of the foot and ankle.
The purpose of this study was to evaluate the pressures generated under the Esmarch tourniquet in a situation that mimics its clinical application, and to determine whether pressures of appropriate magnitude and consistency are obtained in order to recommend its continued use in surgery.
Ten volunteers performed numerous applications of the Esmarch.
The number of wraps and the width of the Esmarch bandage used were varied.
The Esmarch was applied as it would be for a surgical case.
Pressures directly beneath the Esmarch were recorded 8 cm proximal to the distal tip of the medial malleolus.
Considering all volunteers and all pressures generated, a 3-in Esmarch applied with three wraps gave a mean pressure (±SD) of 225 ± 46 mm Hg.
A 3-in Esmarch applied with four wraps gave a mean pressure of 291 ± 53 mm Hg.
A 4-in Esmarch applied with three wraps gave a mean pressure of 233 ± 35 mm Hg, and a 4-in Esmarch with four wraps gave a mean pressure of 284 ± 42 mm Hg.
The maximum pressures generated by any individual were as follows: 3-in three wraps, 321 mm Hg; 3-in four wraps, 413 mm Hg; 4-in three wraps, 328 mm Hg; and 4-in four wraps, 380 mm Hg.
There was no significant difference in the magnitude or consistency of pressures generated between the experienced and inexperienced wrappers.
There did not appear to be a learning curve for the application of the Esmarch bandage.
We conclude that an Esmarch bandage, used as a tourniquet, can generate safe and reliable pressures.
Either a 3-in or 4-in Esmarch bandage applied above the ankle with three circumferential overlapping wraps consistently results in pressures that are in a safe range.

Related Results

Acceptability of Ankle Tourniquet Use in Midfoot and Forefoot Surgery: Audit of 1000 Cases
Acceptability of Ankle Tourniquet Use in Midfoot and Forefoot Surgery: Audit of 1000 Cases
Background: While use of a thigh tourniquet with general anesthesia is widely accepted, use of an ankle tourniquet in the awake patient is more controversial. I...
The Pneumatic Ankle Tourniquet with Ankle Block Anesthesia for Foot Surgery
The Pneumatic Ankle Tourniquet with Ankle Block Anesthesia for Foot Surgery
The use of a pneumatic ankle tourniquet applied to the supramalleolar ankle region is a useful method of obtaining a bloodless field in surgery of the foot. The pneumatic ankle tou...
Analysis of curative effect of low position tourniquet in calcaneal fracture surgery
Analysis of curative effect of low position tourniquet in calcaneal fracture surgery
Abstract This study was designed to investigate the role and curative effect of low position tourniquet in calcaneal fracture surgery. We studied a total of 42 calcaneal fr...
Uterine Isthmus Tourniquet during Abdominal Myomectomy: Support or Hazard? A Randomized Double-Blind Trial
Uterine Isthmus Tourniquet during Abdominal Myomectomy: Support or Hazard? A Randomized Double-Blind Trial
<b><i>Background and Objectives:</i></b> A tourniquet has been suggested as a useful means of reducing massive hemorrhage during myomectomy. However, it is ...
Appropriate tourniquet use in surgery: A literature review
Appropriate tourniquet use in surgery: A literature review
Background: Tourniquet use is ubiquitous in the operating theatre. However, optimal tourniquet usage is unclear, including type, pressure, inflation time, or whether a tourniquet s...
TOURNIQUET USE OR NOT USE IN MYOMECTOMY: AN EXPERIENCE AT SAHIWAL TEACHING HOSPITAL, A RETROSPECTIVE CROSS SECTIONAL STUDY
TOURNIQUET USE OR NOT USE IN MYOMECTOMY: AN EXPERIENCE AT SAHIWAL TEACHING HOSPITAL, A RETROSPECTIVE CROSS SECTIONAL STUDY
Objectives: To evaluate the effectiveness of Tornique use or not use in open Myomectomy and Its ComplicationsMethods: This is a retrospective, single centred cross-sectional study,...
The Burden of Road Traffic Injuries: A Global Perspective
The Burden of Road Traffic Injuries: A Global Perspective
Introduction     Road Traffic Injury (RTI) pose a significant health challenge. It represents the eighth leading cause of death globally, prompting the UN to designate 2011-2020 as...

Back to Top