Javascript must be enabled to continue!
A Validated RP HPLC-PAD Method for the Determination of Hederacoside C in Ivy-Thyme Cough Syrup
View through CrossRef
A simple reversed phase high-performance liquid chromatographic (RP-HPLC) method coupled with a photodiode array detector (PAD) has been developed and validated for the analysis of hederacoside C, the marker of ivy plant, in Ivy-Thyme cough syrup. Separation of hederacoside C was achieved using a Phenomenex-Gemini C18 column isothermally at C. A mobile phase system constituted of solvent A (water: acetonitrile: orthophosphoric acid (85%), 860 : 140 : 2 v/v) and solvent B (acetonitrile: orthophosphoric acid (85%), 998 : 2 v/v) was used, at gradient conditions, at a flow rate of 1.5 mL/min. Analysis was performed using UV-detection (205 nm). The method was linear over the range (0.03–0.15) mg/mL of hederacoside C (). Repeatability and intermediate precision were acceptable (RSD %). Limits of detection (LOD) and quantitation (LOQ) were 0.011 and 0.032 mg/mL, respectively. Percentage recovery was found to lie between 99.69% and 100.90% (RSD %). The method was also proved to be specific (peak-purity ).
Title: A Validated RP HPLC-PAD Method for the Determination of Hederacoside C in Ivy-Thyme Cough Syrup
Description:
A simple reversed phase high-performance liquid chromatographic (RP-HPLC) method coupled with a photodiode array detector (PAD) has been developed and validated for the analysis of hederacoside C, the marker of ivy plant, in Ivy-Thyme cough syrup.
Separation of hederacoside C was achieved using a Phenomenex-Gemini C18 column isothermally at C.
A mobile phase system constituted of solvent A (water: acetonitrile: orthophosphoric acid (85%), 860 : 140 : 2 v/v) and solvent B (acetonitrile: orthophosphoric acid (85%), 998 : 2 v/v) was used, at gradient conditions, at a flow rate of 1.
5 mL/min.
Analysis was performed using UV-detection (205 nm).
The method was linear over the range (0.
03–0.
15) mg/mL of hederacoside C ().
Repeatability and intermediate precision were acceptable (RSD %).
Limits of detection (LOD) and quantitation (LOQ) were 0.
011 and 0.
032 mg/mL, respectively.
Percentage recovery was found to lie between 99.
69% and 100.
90% (RSD %).
The method was also proved to be specific (peak-purity ).
Related Results
Simultaneous Quantification of Hederacoside C and α-hederin in Hedera Nepalensis K.Koch Using HPLC-UV
Simultaneous Quantification of Hederacoside C and α-hederin in Hedera Nepalensis K.Koch Using HPLC-UV
This study develops a high performance liquid chromatography with ultraviolet detection (HPLC-UV) for simultaneous quantification of hederacoside C and α-hederin in Hedera nepalen...
Profile of cough triggers and their relationship with capsaicin cough sensitivity in chronic cough
Profile of cough triggers and their relationship with capsaicin cough sensitivity in chronic cough
Background:
Cough hypersensitivity is an important part of the neurophysiology of cough, which presents with increased cough response to a lower level of stimul...
FREQUENCY OF PERIPHERAL ARTERIAL DISEASE IN PATIENTS PRESENTING WITH ACUTE CORONARY SYNDROME
FREQUENCY OF PERIPHERAL ARTERIAL DISEASE IN PATIENTS PRESENTING WITH ACUTE CORONARY SYNDROME
Background: Coronary artery disease (CAD) is a leading cause of morbidity and mortality worldwide, accounting for 7.4 million of 17.9 million annual cardiovascular deaths. Acute co...
Effects of various natural sweeteners on insulin resistance, inflammation and liver steatosis in a rat model of diet‐induced obesity
Effects of various natural sweeteners on insulin resistance, inflammation and liver steatosis in a rat model of diet‐induced obesity
Background
The detrimental effect of refined sugars on health has been the subject of many investigations. However, very few studies have looked at the long‐ter...
An exploration of clinically meaningful definitions of cough bouts
An exploration of clinically meaningful definitions of cough bouts
RationaleThe measurement of cough frequency is widely used in clinical trials, typically expressed as the number of explosive cough sounds per hour. However, this measure does not ...
Human iPSCs and iPSC-Derived Endothelial Cells from PAD Patients and Healthy Donors Exhibit Comparable Characteristics and Potency: Implications for Autologous Cell Therapy in Peripheral Artery Disease
Human iPSCs and iPSC-Derived Endothelial Cells from PAD Patients and Healthy Donors Exhibit Comparable Characteristics and Potency: Implications for Autologous Cell Therapy in Peripheral Artery Disease
ABSTRACT
BACKGROUND
Peripheral artery disease (PAD) can lead to amputation in advanced cases, making cell therapy using human i...
Identification and Determination of Metal Elements of Dates Syrup Extracted from Various Varieties Using SEM-EDS Technique
Identification and Determination of Metal Elements of Dates Syrup Extracted from Various Varieties Using SEM-EDS Technique
This study has been conducted to determine and identify the metal elements of dates syrup extracted from Khstawy, Zehdy and Shukary using Scanning electron microscope-Energy disper...
Fetuin-A Levels Are Increased in Patients With Type 2 Diabetes and Peripheral Arterial Disease
Fetuin-A Levels Are Increased in Patients With Type 2 Diabetes and Peripheral Arterial Disease
OBJECTIVE
Low levels of fetuin-A, a systemic calcification inhibitor, are linked to mortality in patients on dialysis. In contrast, elevated fetuin-A is associate...

