Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A Validated RP HPLC-PAD Method for the Determination of Hederacoside C in Ivy-Thyme Cough Syrup

View through CrossRef
A simple reversed phase high-performance liquid chromatographic (RP-HPLC) method coupled with a photodiode array detector (PAD) has been developed and validated for the analysis of hederacoside C, the marker of ivy plant, in Ivy-Thyme cough syrup. Separation of hederacoside C was achieved using a Phenomenex-Gemini C18 column isothermally at C. A mobile phase system constituted of solvent A (water: acetonitrile: orthophosphoric acid (85%), 860 : 140 : 2 v/v) and solvent B (acetonitrile: orthophosphoric acid (85%), 998 : 2 v/v) was used, at gradient conditions, at a flow rate of 1.5 mL/min. Analysis was performed using UV-detection (205 nm). The method was linear over the range (0.03–0.15) mg/mL of hederacoside C (). Repeatability and intermediate precision were acceptable (RSD %). Limits of detection (LOD) and quantitation (LOQ) were 0.011 and 0.032 mg/mL, respectively. Percentage recovery was found to lie between 99.69% and 100.90% (RSD %). The method was also proved to be specific (peak-purity ).
Title: A Validated RP HPLC-PAD Method for the Determination of Hederacoside C in Ivy-Thyme Cough Syrup
Description:
A simple reversed phase high-performance liquid chromatographic (RP-HPLC) method coupled with a photodiode array detector (PAD) has been developed and validated for the analysis of hederacoside C, the marker of ivy plant, in Ivy-Thyme cough syrup.
Separation of hederacoside C was achieved using a Phenomenex-Gemini C18 column isothermally at C.
A mobile phase system constituted of solvent A (water: acetonitrile: orthophosphoric acid (85%), 860 : 140 : 2 v/v) and solvent B (acetonitrile: orthophosphoric acid (85%), 998 : 2 v/v) was used, at gradient conditions, at a flow rate of 1.
5 mL/min.
Analysis was performed using UV-detection (205 nm).
The method was linear over the range (0.
03–0.
15) mg/mL of hederacoside C ().
Repeatability and intermediate precision were acceptable (RSD %).
Limits of detection (LOD) and quantitation (LOQ) were 0.
011 and 0.
032 mg/mL, respectively.
Percentage recovery was found to lie between 99.
69% and 100.
90% (RSD %).
The method was also proved to be specific (peak-purity ).

Related Results

Simultaneous Quantification of Hederacoside C and α-hederin in Hedera Nepalensis K.Koch Using HPLC-UV
Simultaneous Quantification of Hederacoside C and α-hederin in Hedera Nepalensis K.Koch Using HPLC-UV
 This study develops a high performance liquid chromatography with ultraviolet detection (HPLC-UV) for simultaneous quantification of hederacoside C and α-hederin in Hedera nepalen...
FREQUENCY OF PERIPHERAL ARTERIAL DISEASE IN PATIENTS PRESENTING WITH ACUTE CORONARY SYNDROME
FREQUENCY OF PERIPHERAL ARTERIAL DISEASE IN PATIENTS PRESENTING WITH ACUTE CORONARY SYNDROME
Background: Coronary artery disease (CAD) is a leading cause of morbidity and mortality worldwide, accounting for 7.4 million of 17.9 million annual cardiovascular deaths. Acute co...
Fetuin-A Levels Are Increased in Patients With Type 2 Diabetes and Peripheral Arterial Disease
Fetuin-A Levels Are Increased in Patients With Type 2 Diabetes and Peripheral Arterial Disease
OBJECTIVE Low levels of fetuin-A, a systemic calcification inhibitor, are linked to mortality in patients on dialysis. In contrast, elevated fetuin-A is associate...
Methods of Objectifying Cough
Methods of Objectifying Cough
Abstract Cough is one of the most common symptoms encountered by clinicians. Attempts to measure cough date back to early 1950s and since then, significant progre...
Identification and prevention of “Black Pad” in Sn/Pb soldering
Identification and prevention of “Black Pad” in Sn/Pb soldering
PurposeThe use of an electroless nickel/immersion gold (ENIG) surface finish comes with the inherent potential risk of Black Pad failures that can cause fracture embrittlement at t...
CT ANATOMY OF BUCCAL FAT PAD AND ITS ROLE IN VOLUMETRIC ALTERATIONS OF FACE
CT ANATOMY OF BUCCAL FAT PAD AND ITS ROLE IN VOLUMETRIC ALTERATIONS OF FACE
Abstract. The aim of our study is the revision of the anatomy of buccal fat pad and its role in a volumetric pattern of face. Bichat fat pad is a fatty anatomical structure with bo...

Back to Top