Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Fatigue Assessment of Prestressed Concrete Slab-between-Girder Bridges

View through CrossRef
In the Netherlands, the assessment of existing prestressed concrete slab-between-girder bridges showed that the thin, transversely prestressed slabs may be critical for static and fatigue punching when evaluated using the recently introduced Eurocodes. On the other hand, compressive membrane action increases the capacity of these slabs and changes the failure mode from bending to punching shear. To improve the assessment of the existing prestressed slab-between-girder bridges in the Netherlands, two 1:2 scale models of an existing bridge, the Van Brienenoord Bridge, were built in the laboratory and tested monotonically as well as under cycles of loading. The result of these experiments is: 1) the static strength of the decks, showing that compressive membrane action significantly enhances the punching capacity, and 2) the Wöhler curve of the decks, showing that compressive membrane action remains under fatigue loading. The experimental results can then be used for the assessment of the most critical existing slab-between-girder bridge. The outcome is that the bridge has sufficient punching capacity for static and fatigue loads, and thus that the existing slab-between-girder bridges in the Netherlands fulfil the code requirements for static and fatigue punching.
Title: Fatigue Assessment of Prestressed Concrete Slab-between-Girder Bridges
Description:
In the Netherlands, the assessment of existing prestressed concrete slab-between-girder bridges showed that the thin, transversely prestressed slabs may be critical for static and fatigue punching when evaluated using the recently introduced Eurocodes.
On the other hand, compressive membrane action increases the capacity of these slabs and changes the failure mode from bending to punching shear.
To improve the assessment of the existing prestressed slab-between-girder bridges in the Netherlands, two 1:2 scale models of an existing bridge, the Van Brienenoord Bridge, were built in the laboratory and tested monotonically as well as under cycles of loading.
The result of these experiments is: 1) the static strength of the decks, showing that compressive membrane action significantly enhances the punching capacity, and 2) the Wöhler curve of the decks, showing that compressive membrane action remains under fatigue loading.
The experimental results can then be used for the assessment of the most critical existing slab-between-girder bridge.
The outcome is that the bridge has sufficient punching capacity for static and fatigue loads, and thus that the existing slab-between-girder bridges in the Netherlands fulfil the code requirements for static and fatigue punching.

Related Results

Reliability Assessment Approach for Fire-resistance Performance of Prestressed Steel-Concrete Box Girder Bridges
Reliability Assessment Approach for Fire-resistance Performance of Prestressed Steel-Concrete Box Girder Bridges
This paper uses probability method to evaluate the fire safety performance of prestressed steel-concrete beam bridges based on simulation experimental research. Firstly, fire simul...
EXPERIMENTAL STUDY ON SHEAR PERFORMANCE AND BEARING CAPACITY OF PRESTRESSED CONCRETE T-BEAMS
EXPERIMENTAL STUDY ON SHEAR PERFORMANCE AND BEARING CAPACITY OF PRESTRESSED CONCRETE T-BEAMS
Prestressed concrete t-beams have complex shear mechanism, and their shear performance is influenced by various factors, such as flange width and prestress. The shear performance o...
00.06: Advances and development needs in the structural design of steel box girders for major bridges
00.06: Advances and development needs in the structural design of steel box girders for major bridges
ABSTRACTMajor cable‐supported bridges with a span exceeding 600m would not normally be feasible without a steel box girder to carry the traffic load. These box girders generally co...
Analysis of the Condition of Tendons in Prestressed Concrete Structures
Analysis of the Condition of Tendons in Prestressed Concrete Structures
Prestressing Steel Fracture Detection Bernd Hillemeier, Simon Knapp, Thomas Luther Abstract The earliest possible non-destructive location of a prestressing steel fracture is a...
Assessment of Objective and Subjective Fatigubility in Obese
Assessment of Objective and Subjective Fatigubility in Obese
Aim: This study aimed to quantify objective fatigue using the Long Distance Corridor Walk (2-Minute Walk Test and 400-Meter Walk Test) and evaluate subjective fatigue using the Fat...
Influence of railings stiffness on wheel load distribution in two-span multilane concrete slab bridges
Influence of railings stiffness on wheel load distribution in two-span multilane concrete slab bridges
Highway bridge specifications do not account for the presence of railings or parapets in the analysis and design of concrete slab bridges. This paper presents a parametric investig...
FRICTION TEST AND PARAMETER ANALYSIS OF PRESTRESSED CONCRETE CONTINUOUS BEAM BRIDGE
FRICTION TEST AND PARAMETER ANALYSIS OF PRESTRESSED CONCRETE CONTINUOUS BEAM BRIDGE
The prestressed ducts of prestressed concrete continuous girder bridges are usually three-dimensionally distributed and long in length. The control of prestress loss during constru...
Research Flexural Properties of Prestressed Slabs
Research Flexural Properties of Prestressed Slabs
This paper is aimed to study on the flexural performance of prestressed slab and prestressed composite slab ,in order to provide the reference in engineering.At first,the prestress...

Back to Top