Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Anterior cervical transpedicular screw fixation system in subaxial cervical spine: A finite element comparative study

View through CrossRef
Multilevel cervical corpectomy has raised the concern among surgeons that reconstruction with the anterior cervical screw plate system (ACSPS) alone may fail eventually. As an alternative, the anterior cervical transpedicular screw (ACTPS) has been adopted in clinical practice. We used the finite element analysis to investigate whether ACTPS is a more reasonable choice, in comparison with ACSPS, after a 2-level corpectomy in the subaxial cervical spine. These 2 types of implantation models with the applied 75 N axial pressure and 1 N • m pure moment of the couple were evaluated. Compared with the intact model, the range of motion (ROM) at the operative segments (C4–C7) decreased by 97.5% in flexion-extension, 91.3% in axial rotation, and 99.3% in lateral bending in the ACTPS model, whereas it decreased by 95.1%, 73.4%, 96.9% in the ACSPS model respectively. The ROM at the adjacent segment (C3/4) in the ACTPS model decreased in all motions, while that of the ACSPS model increased in axial rotation and flexion-extension compared with the intact model. Compared to the ACSPS model, whose stress concentrated on the interface between the screws and the titanium plate, the stress of the ACTPS model was well-distributed. There was also a significant difference between the maximum stress value of the 2 models. ACTPS and ACSPS are biomechanically favorable. The stability in reducing ROM of ACTPS may be better and the risk of failure for internal fixator is relatively low compared with ACSPS fixation except for under lateral bending in reconstruction the stability of the subaxial cervical spine after 2-level corpectomy.
Title: Anterior cervical transpedicular screw fixation system in subaxial cervical spine: A finite element comparative study
Description:
Multilevel cervical corpectomy has raised the concern among surgeons that reconstruction with the anterior cervical screw plate system (ACSPS) alone may fail eventually.
As an alternative, the anterior cervical transpedicular screw (ACTPS) has been adopted in clinical practice.
We used the finite element analysis to investigate whether ACTPS is a more reasonable choice, in comparison with ACSPS, after a 2-level corpectomy in the subaxial cervical spine.
These 2 types of implantation models with the applied 75 N axial pressure and 1 N • m pure moment of the couple were evaluated.
Compared with the intact model, the range of motion (ROM) at the operative segments (C4–C7) decreased by 97.
5% in flexion-extension, 91.
3% in axial rotation, and 99.
3% in lateral bending in the ACTPS model, whereas it decreased by 95.
1%, 73.
4%, 96.
9% in the ACSPS model respectively.
The ROM at the adjacent segment (C3/4) in the ACTPS model decreased in all motions, while that of the ACSPS model increased in axial rotation and flexion-extension compared with the intact model.
Compared to the ACSPS model, whose stress concentrated on the interface between the screws and the titanium plate, the stress of the ACTPS model was well-distributed.
There was also a significant difference between the maximum stress value of the 2 models.
ACTPS and ACSPS are biomechanically favorable.
The stability in reducing ROM of ACTPS may be better and the risk of failure for internal fixator is relatively low compared with ACSPS fixation except for under lateral bending in reconstruction the stability of the subaxial cervical spine after 2-level corpectomy.

Related Results

Lateral Mass Fixation in Subaxial Cervical Spine: Anatomic Review
Lateral Mass Fixation in Subaxial Cervical Spine: Anatomic Review
Introduction The cervical spine is a highly mobile segment of the spinal column, liable to a variety of diseases and susceptible to trauma. It is a complex regi...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Biomechanical Evaluation of Subaxial Lateral Mass Prothesis: A Finite Element Analysis Study
Biomechanical Evaluation of Subaxial Lateral Mass Prothesis: A Finite Element Analysis Study
Abstract Background: Pathologies of a lateral masses due to trauma, tumors, and surgery, could lead to bone destruction and biomechanical changes of the cervical spine. The...
Comparison between upper thoracic spine mobilization and the Ergon technique in the treatment of mechanical neck pain
Comparison between upper thoracic spine mobilization and the Ergon technique in the treatment of mechanical neck pain
Upper thoracic spine mobilization and the Ergon technique are used to treat mechanical neck pain in order to speed recovery, promote tissue healing and improve range of motion. The...
Computed Tomographic Measurement of Cervical Pedicle Morphology in Filipino Patients
Computed Tomographic Measurement of Cervical Pedicle Morphology in Filipino Patients
Introduction: Studies have shown that Asian cervical pedicles are significantly smaller, thus increasing the technical difficulty of screw insertion when using standard 3.5 mm ped...
The Outcome of Minimally Invasive Percutaneous Transpedicular Screw Fixation (TPSF) in Thoracolumbar Spine Fractures
The Outcome of Minimally Invasive Percutaneous Transpedicular Screw Fixation (TPSF) in Thoracolumbar Spine Fractures
Background & Objective:  This study aimed to determine the outcome of percutaneous transpedicular screw fixation (TPSF) in patients with thoracolumbar fractures. Material...
Anterior Hollow Screw Fixation Combined with Posterior Lateral Mass Screws Fixation to Treat A Huge Tear Drop Fracture of The Axis
Anterior Hollow Screw Fixation Combined with Posterior Lateral Mass Screws Fixation to Treat A Huge Tear Drop Fracture of The Axis
Teardrop fracture of axis is rarely seen, especially the huge type. The surgical approach is controversial and individualized in the literature. We reported a special case to share...

Back to Top