Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Pupillary Diameter Change and Dynamics in Different Refractive Error Groups after Implantation of a Collamer Lens with a Central Hole Without Viscoelastic Agent

View through CrossRef
Background: To investigate the pupillary diameter and dynamics in different refractive error groups after non viscoelastic agent assisted implantation of a collamer lens with a central hole, so as to evaluate the effect on the pupil of this type of surgery.
Title: Pupillary Diameter Change and Dynamics in Different Refractive Error Groups after Implantation of a Collamer Lens with a Central Hole Without Viscoelastic Agent
Description:
Background: To investigate the pupillary diameter and dynamics in different refractive error groups after non viscoelastic agent assisted implantation of a collamer lens with a central hole, so as to evaluate the effect on the pupil of this type of surgery.

Related Results

Implantable collamer lens with a central hole for residual refractive error correction after corneal refractive surgery
Implantable collamer lens with a central hole for residual refractive error correction after corneal refractive surgery
Abstract PURPOSE: To assess the visual and refractive outcomes of an implantable collamer lens with a central hole (ICL V4c) for residual refractive error correction after ...
Retinitis Pigmentosa
Retinitis Pigmentosa
In studying the cases with typical and atypical pigmentary degeneration of the retina we strived to analyse in the clinical material all ophthalmoscopic and ocular changes together...
The peridynamic model of viscoelastic creep and recovery
The peridynamic model of viscoelastic creep and recovery
Purpose – The purpose of this paper is to establish a peridynamic method in predicting viscoelastic creep behaviour with recovery stage and to find the suitable num...
Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up
Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up
AIM: To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port (V4c T-ICL) implantation over 1y of follow-up. METHOD...
Comparison of Visual Outcomes of Extended Depth of Focus Lenses in Patients With and Without Previous Laser Refractive Surgery
Comparison of Visual Outcomes of Extended Depth of Focus Lenses in Patients With and Without Previous Laser Refractive Surgery
PURPOSE: To compare visual outcomes of eyes with and without previous laser refractive surgery that received an extended depth of focus intraocular lens during cataract...

Back to Top