Javascript must be enabled to continue!
Biomechanical evaluation of a new standard temporomandibular joint prosthesis and screw arrangement optimization: A finite element analysis.
View through CrossRef
Abstract
Background: Artificial total joint replacement is an important method of temporomandibular joint (TMJ) reconstruction, which has been advocated for TMJ osteoarthrosis, ankylosis, tumors and other diseases. We designed one type of a standard TMJ prosthesis fit for Chinese patients. This study explores the biomechanical behavior of the standard TMJ prosthesis using finite element analysis and selects an optimal screw arrangement scheme for clinical application. Methods: A female volunteer was recruited for a maxillofacial computed tomography (CT) scan, then the Hypermesh software was used to establish a finite element model of a mandibular condyle defect repaired with an artificial TMJ prosthesis. LS-DYNA software was used to calculate the stress and deformation under a simulated maximum bite force loading. Also, the forces of screws under different numbers and arrangements were analyzed. Meanwhile, we designed an experiment to verify the calculation model.Results: The average maximum stress of the fossa component of the standard prosthesis model was 19.25 MPa. The average maximum stress of the condyle component was 82.58 MPa, mainly concentrated near the top row hole. The fossa component should be fixed with at least 3 screws, and the optimal number of screws was 4. The condyle component should be fixed with at least 4 screws, and its optimal number was 6. The best scheme of screw arrangement was determined. The results of the verification experiment showed that the analysis was reliable.Conclusions: The stress distribution of the standard TMJ prosthesis is uniform, meanwhile, the number and arrangement of the screws significantly affect the contact force of the screws.
Title: Biomechanical evaluation of a new standard temporomandibular joint prosthesis and screw arrangement optimization: A finite element analysis.
Description:
Abstract
Background: Artificial total joint replacement is an important method of temporomandibular joint (TMJ) reconstruction, which has been advocated for TMJ osteoarthrosis, ankylosis, tumors and other diseases.
We designed one type of a standard TMJ prosthesis fit for Chinese patients.
This study explores the biomechanical behavior of the standard TMJ prosthesis using finite element analysis and selects an optimal screw arrangement scheme for clinical application.
Methods: A female volunteer was recruited for a maxillofacial computed tomography (CT) scan, then the Hypermesh software was used to establish a finite element model of a mandibular condyle defect repaired with an artificial TMJ prosthesis.
LS-DYNA software was used to calculate the stress and deformation under a simulated maximum bite force loading.
Also, the forces of screws under different numbers and arrangements were analyzed.
Meanwhile, we designed an experiment to verify the calculation model.
Results: The average maximum stress of the fossa component of the standard prosthesis model was 19.
25 MPa.
The average maximum stress of the condyle component was 82.
58 MPa, mainly concentrated near the top row hole.
The fossa component should be fixed with at least 3 screws, and the optimal number of screws was 4.
The condyle component should be fixed with at least 4 screws, and its optimal number was 6.
The best scheme of screw arrangement was determined.
The results of the verification experiment showed that the analysis was reliable.
Conclusions: The stress distribution of the standard TMJ prosthesis is uniform, meanwhile, the number and arrangement of the screws significantly affect the contact force of the screws.
Related Results
Biomechanical Evaluation of Subaxial Lateral Mass Prothesis: A Finite Element Analysis Study
Biomechanical Evaluation of Subaxial Lateral Mass Prothesis: A Finite Element Analysis Study
Abstract
Background: Pathologies of a lateral masses due to trauma, tumors, and surgery, could lead to bone destruction and biomechanical changes of the cervical spine. The...
WITHDRAWN: Establishment of a Finite Element Model and Biomechanical Analysis of Different Fixation Methods for Total Talar Prosthesis Replacement
WITHDRAWN: Establishment of a Finite Element Model and Biomechanical Analysis of Different Fixation Methods for Total Talar Prosthesis Replacement
Abstract
Background:
As a new technology, three-dimensional (3D)-printed personalized talar prostheses are associated with diff...
Biomechanical comparison between the custom-made mandibular condyle prosthesis and total temporomandibular joint prosthesis in finite element analysis
Biomechanical comparison between the custom-made mandibular condyle prosthesis and total temporomandibular joint prosthesis in finite element analysis
Purpose: The purpose of this study was to compare the biomechanical behavior of the custom-made mandibular condyle prosthesis and total TMJ prosthesis. Methods: Three models of one...
Abordagem terapêutica nas desordens temporomandibulares: técnicas de fisioterapia associadas ao tratamento odontológico
Abordagem terapêutica nas desordens temporomandibulares: técnicas de fisioterapia associadas ao tratamento odontológico
Responsáveis por amplo e variado quadro de sinais e sintomas de difícil diagnóstico, as desordens da articulação temporomandibular exigem tratamento complexo e multifatorial, já qu...
Study on Positioning Accuracy of Aerostatic Lead Screw
Study on Positioning Accuracy of Aerostatic Lead Screw
The aerostatic lead screw is a non-contact type lead screw in which the contact surface of a male screw and a female screw is supported by a pressurized air film. It is characteriz...
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Biomechanical analysis of pedicle screw density in spinal instrumentation for scoliosis treatment: first results
Clinical studies reveal remarkable variation in screw patterns, or screw density in spinal instrumentation. Screw density may have a great impact on blood loss, operative time, rad...
Articular Eminence Inclination and Glenoid Fossa Measurements by CBCT in Patients with Temporomandibular Joint Disorders
Articular Eminence Inclination and Glenoid Fossa Measurements by CBCT in Patients with Temporomandibular Joint Disorders
Background: The increasing frequency of temporomandibular joint dysfunction requires the promotion of diagnostic and therapeutic approaches. The several etiologies of dysfunction a...
SCF Equations for T/Y and K Square-to-Round Tubular Joint
SCF Equations for T/Y and K Square-to-Round Tubular Joint
Summary
A parametric stress analysis of T/Y and K square-to-round tubular joints subjected to axial loads and in-plane and out-of-plane bending moments has been p...

