Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Measuring image sharpness using modulation transfer function in magnetic resonance imaging

View through CrossRef
Background/Objectives: The purpose of this study was to propose a method to maintain the objectivity and validity of measuring image sharpness by changes of ETL using MTF in MRI quantitatively and provide fundamental data for future evaluation and management of magnetic resource imaging quality. Methods/Statistical analysis: We conducted phantom test using ACR MRI phantom. ImageJ and OriginPro programs were used for MTF measurement. For MTF measurement using edge method, after achieving ESF by using ImageJ, LSF was calculated by differentiation in OriginPro. Finally, MTF value was obtained through conversion. Image sharpness was defined based on 50% of MTF value. Findings: Results of sharpness measurement by ETL increase revealed that MTF 50% was decreased when ETL was increased. Sharpness comparison between 1ch head coil and 8ch brain coil at 1.5T showed that it was higher for 1ch head coil, although the difference between the two was not statistically significant. However, sharpness of 1ch head coil at 3.0T MRI was found to be significantly higher than that of 8ch brain coil at 3.0T MRI. Improvements/Applications: This study confirms the theoretical concept that MTF measured by ACR standard phantom can be used as a quantitative evaluation method for spatial resolution in the magnetic resonance medical image quality management. It can be considered a meaningful objective evaluation method.
Title: Measuring image sharpness using modulation transfer function in magnetic resonance imaging
Description:
Background/Objectives: The purpose of this study was to propose a method to maintain the objectivity and validity of measuring image sharpness by changes of ETL using MTF in MRI quantitatively and provide fundamental data for future evaluation and management of magnetic resource imaging quality.
Methods/Statistical analysis: We conducted phantom test using ACR MRI phantom.
ImageJ and OriginPro programs were used for MTF measurement.
For MTF measurement using edge method, after achieving ESF by using ImageJ, LSF was calculated by differentiation in OriginPro.
Finally, MTF value was obtained through conversion.
Image sharpness was defined based on 50% of MTF value.
Findings: Results of sharpness measurement by ETL increase revealed that MTF 50% was decreased when ETL was increased.
Sharpness comparison between 1ch head coil and 8ch brain coil at 1.
5T showed that it was higher for 1ch head coil, although the difference between the two was not statistically significant.
However, sharpness of 1ch head coil at 3.
0T MRI was found to be significantly higher than that of 8ch brain coil at 3.
0T MRI.
Improvements/Applications: This study confirms the theoretical concept that MTF measured by ACR standard phantom can be used as a quantitative evaluation method for spatial resolution in the magnetic resonance medical image quality management.
It can be considered a meaningful objective evaluation method.

Related Results

Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...
Analysis of magnetohydrodynamic drag character for hypersonic vehicles
Analysis of magnetohydrodynamic drag character for hypersonic vehicles
In hypersonic flight, a very high temperature area can form ahead of the nose of aerocraft due to the shock aerodynamic heating, which leads to air weakly ionized. Many researchers...
The future of magnetic resonance‐based techniques in neurology
The future of magnetic resonance‐based techniques in neurology
Magnetic resonance techniques have become increasingly important in neurology for defining: 1 brain, spinal cord and peripheral nerve or muscle structure; 2 pathological changes in...
Method of liquid consumption measuring in nuclear magnetic flowmeters-relaxometers
Method of liquid consumption measuring in nuclear magnetic flowmeters-relaxometers
The need to expand the functionality of systems for monitoring the parameters of the flow of liquid media is substantiated. The advantages of using meters based on the phenomenon o...
A retrospective study on the diagnostic values of magnetic resonance examination of the anal canal in the classification of anal fistula
A retrospective study on the diagnostic values of magnetic resonance examination of the anal canal in the classification of anal fistula
Objective: To explore the diagnostic value of magnetic resonance imaging of the anal canal in classifying anal fistula.Method: The retrospective study was conducted at Yongli Wu, D...
Procedure for Western blot v1
Procedure for Western blot v1
Goal: This document has the objective of standardizing the protocol for Western blot. This technique allows the detection of specific proteins separated on polyacrylamide gel and t...
Double Exposure
Double Exposure
I. Happy Endings Chaplin’s Modern Times features one of the most subtly strange endings in Hollywood history. It concludes with the Tramp (Chaplin) and the Gamin (Paulette Godda...
ACOUSTIC NEUROMA;
ACOUSTIC NEUROMA;
Objectives: To determine the diagnostic accuracy of magnetic resonance imaging in the detection of acoustic neuroma taking histopathology as gold standard. Study Design: Cross-sect...

Back to Top